Michael H. Boevé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael H. Boevé has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Ohnesorge
Clinic for Horses, University of Veterinary Medicine Hannover, Foundation, Hannover, Germany
3 shared publications - Ulrike Meister
Stiftung Tierärztliche Hochschule Hannover, Klinik für Pferde, Bünteweg 9, 30559 Hannover, Germany
2 shared publications - Christiane Görig
De Graafschap dierenartsen, Schimmeldijk 1, 7251 MX Vorden, The Netherlands
1 shared publication - Christopher J. Murphy
Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA 95616, USA
1 shared publication - Daniel Körner
Theoretisch-Physikalisches Institut, Friedrich-Schiller-Universität Jena, 07743, Jena, Germany.
1 shared publication - Hubertus Haan
HENSOLDT Optronics GmbH, Carl-Zeiss-Str. 22, 73447 Oberkochen, Germany
1 shared publication
Latest Publications
- Open Access
- 3 April 2018
- Published by Springer Nature in BMC Veterinary Research
- Vol. 14 (1) , 123
Intraocular lens power calculation for the equine eye
Phacoemulsification and intraocular lens (IOL) implantation during cataract surgery in horses occur with increasing frequency. To reduce the postoperative refractive error it is necessary to determine the proper IOL power. In the present study retinoscopy, keratometry and ultrasonographic biometry were performed on 98 healthy equine eyes from 49 horses. The refractive state, corneal curvature (keratometry) and the axial location of all optical interfaces (biometry) were measured. The influences of breed, height at the withers, gender and age on values obtained and the comparison between the left and right eye were evaluated statistically. Corresponding IOL power were calculated by use of Binkhorst and Retzlaff theoretical formulas. Mean ± SD refractive state of the horses was + 0.32 ± 0.66 D. Averaged corneal curvature for Haflinger, Friesian, Pony, Shetland pony and Warmblood were 21.30 ± 0.56 D, 20.02 ± 0.60 D, 22.61 ± 1.76 D, 23.77 ± 0.94 D and 20.76 ± 0.88 D, respectively. The estimated postoperative anterior chamber depth (C) was calculated by the formula C = anterior chamber depth (ACD)/0.73. This formula was determined by a different research group. C and axial length of the globe averaged for Haflinger 9.30 ± 0.54 mm and 39.43 ± 1.26 mm, for Friesian 10.12 ± 0.33 mm and 42.23 ± 1.00 mm, for Pony 8.68 ± 0.78 mm and 38.85 ± 3.13 mm, for Shetland pony 8.71 ± 0.81 mm and 37.21 ± 1.50 mm and for Warmblood 9.39 ± 0.51 mm and 40.65 ± 1.30 mm. IOL power was calculated with the Binkhorst and Retzlaff theoretical formulas. Calculated IOL power for the several breeds ranged from 18.03 D to 19.55 D. The mean value across all horses was 18.73 D determined with Binkhorst formula and 18.54 D determined with Retzlaff formula. Mean result of this study is: an 18.5 D IOL seemed to be the most appropriate to achieve emmetropia after IOL implantation in horses. Cataract surgery without IOL implantation results in hyperopic and visual compromised horses. Retinoscopy, keratometry and ultrasonographic biometry should be performed on every affected horse and postoperative visual outcome should be determined.
- 3 April 2018
- Published by Springer Nature in BMC Veterinary Research
- Vol. 14 (1) , 123
Open AccessIntraocular lens power calculation for the equine eye
Phacoemulsification and intraocular lens (IOL) implantation during cataract surgery in horses occur with increasing frequency. To reduce the postoperative refractive error it is necessary to determine the proper IOL power. In the present study retinoscopy, keratometry and ultrasonographic biometry were performed on 98 healthy equine eyes from 49 horses. The refractive state, corneal curvature (keratometry) and the axial location of all optical interfaces (biometry) were measured. The influences of breed, height at the withers, gender and age on values obtained and the comparison between the left and right eye were evaluated statistically. Corresponding IOL power were calculated by use of Binkhorst and Retzlaff theoretical formulas. Mean ± SD refractive state of the horses was + 0.32 ± 0.66 D. Averaged corneal curvature for Haflinger, Friesian, Pony, Shetland pony and Warmblood were 21.30 ± 0.56 D, 20.02 ± 0.60 D, 22.61 ± 1.76 D, 23.77 ± 0.94 D and 20.76 ± 0.88 D, respectively. The estimated postoperative anterior chamber depth (C) was calculated by the formula C = anterior chamber depth (ACD)/0.73. This formula was determined by a different research group. C and axial length of the globe averaged for Haflinger 9.30 ± 0.54 mm and 39.43 ± 1.26 mm, for Friesian 10.12 ± 0.33 mm and 42.23 ± 1.00 mm, for Pony 8.68 ± 0.78 mm and 38.85 ± 3.13 mm, for Shetland pony 8.71 ± 0.81 mm and 37.21 ± 1.50 mm and for Warmblood 9.39 ± 0.51 mm and 40.65 ± 1.30 mm. IOL power was calculated with the Binkhorst and Retzlaff theoretical formulas. Calculated IOL power for the several breeds ranged from 18.03 D to 19.55 D. The mean value across all horses was 18.73 D determined with Binkhorst formula and 18.54 D determined with Retzlaff formula. Mean result of this study is: an 18.5 D IOL seemed to be the most appropriate to achieve emmetropia after IOL implantation in horses. Cataract surgery without IOL implantation results in hyperopic and visual compromised horses. Retinoscopy, keratometry and ultrasonographic biometry should be performed on every affected horse and postoperative visual outcome should be determined.
- Open Access
- 14 October 2014
- Published by Springer Nature in BMC Veterinary Research
- Vol. 10 (1) , 250
Evaluation of ultrasound velocity in enucleated equine aqueous humor, lens and vitreous body
Sonographic ophthalmic examinations have become increasingly important in veterinary medicine. If the velocity of ultrasound in ocular tissues is known, the A-mode ultrasound method may be used to determine the axial intraocular distances, such as anterior chamber depth, lens thickness, axial length of the vitreous and axial globe length, which are required for intraocular lens (IOL) power calculations. To the authors' knowledge, the velocity of ultrasound in the ocular tissues of the horse was not previously determined. In the present study, 33 lenses, 29 samples of aqueous and 31 of vitreous from 35 healthy equine eyes have been examined. The corresponding ultrasound velocities are reported in dependence of age, temperature, gender and elapsed time after enucleation. The velocity of ultrasound at 36°C in equine aqueous, lens and vitreous are 1529 ±10 m/s, 1654± 29 m/s and 1527 ±16 m/s respectively, and the corresponding conversion factors are 0.998± 0.007, 1.008 ±0.018 and 0.997 ±0.010. A linear increase of the speed of ultrasound with increasing temperature has been determined for aqueous and vitreous. No temperature dependence was found for the speed of ultrasound in the lens. The ultrasound velocity did not significantly differ (95%) on the basis of gender, age or time after enucleation during the first 72 hours after death. Compared to human eyes, the ultrasound velocity in equine lental tissue deviates by one percent. Therefore, axial length measurements obtained with ultrasound velocities for the human eye must be corrected using conversion factors. For the aqueous and vitreous, deviations are below one percent and can be neglected in clinical settings.
- 14 October 2014
- Published by Springer Nature in BMC Veterinary Research
- Vol. 10 (1) , 250
Open AccessEvaluation of ultrasound velocity in enucleated equine aqueous humor, lens and vitreous body
Sonographic ophthalmic examinations have become increasingly important in veterinary medicine. If the velocity of ultrasound in ocular tissues is known, the A-mode ultrasound method may be used to determine the axial intraocular distances, such as anterior chamber depth, lens thickness, axial length of the vitreous and axial globe length, which are required for intraocular lens (IOL) power calculations. To the authors' knowledge, the velocity of ultrasound in the ocular tissues of the horse was not previously determined. In the present study, 33 lenses, 29 samples of aqueous and 31 of vitreous from 35 healthy equine eyes have been examined. The corresponding ultrasound velocities are reported in dependence of age, temperature, gender and elapsed time after enucleation. The velocity of ultrasound at 36°C in equine aqueous, lens and vitreous are 1529 ±10 m/s, 1654± 29 m/s and 1527 ±16 m/s respectively, and the corresponding conversion factors are 0.998± 0.007, 1.008 ±0.018 and 0.997 ±0.010. A linear increase of the speed of ultrasound with increasing temperature has been determined for aqueous and vitreous. No temperature dependence was found for the speed of ultrasound in the lens. The ultrasound velocity did not significantly differ (95%) on the basis of gender, age or time after enucleation during the first 72 hours after death. Compared to human eyes, the ultrasound velocity in equine lental tissue deviates by one percent. Therefore, axial length measurements obtained with ultrasound velocities for the human eye must be corrected using conversion factors. For the aqueous and vitreous, deviations are below one percent and can be neglected in clinical settings.
- 1 February 2007
- Published by Georg Thieme Verlag KG in pferde spiegel
- Vol. 10 (02) , 51-58
Medikamentelle und chirurgische Therapie bei Hornhautulzera des Pferdes
- 1 February 2007
- Published by Georg Thieme Verlag KG in pferde spiegel
- Vol. 10 (02) , 51-58
Medikamentelle und chirurgische Therapie bei Hornhautulzera des Pferdes