No difference between mobile and fixed bearing in primary total knee arthroplasty: a meta‐analysis
Open Access
- 21 July 2022
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (9) , 3138-3154
Abstract
Purpose: Both mobile (MB) and fixed (FB) bearing implants are routinely used for total knee arthroplasty (TKA). This meta‐analysis compared MB versus FB for TKA in terms of implant positioning, joint function, patient reported outcome measures (PROMs), and complications. It was hypothesised that MB performs better than FB implants in primary TKA.Methods: This meta‐analysis was conducted according to the 2020 PRISMA statement. In February 2022, the following databases were accessed: Pubmed, Web of Science, Google Scholar, Embase. All the randomized clinical trials (RCTs) comparing mobile versus fixed bearing for primary TKA were considered.Results: Data from 74 RCTs (11,116 procedures) were retrieved. The mean follow‐up was 58.8 (7.5 to 315.6) months. The MB group demonstrated greater range of motion (ROM) (P = 0.02), Knee Society Score (KSS) score (P < 0.0001), and rate of deep infections (P = 0.02). No difference was found in implant positioning: tibial slope, delta angle, alpha femoral component angle, gamma femoral component angle, beta tibial component angle, tibiofemoral alignment angle, posterior condylar offset, radiolucent lines. No difference was found in duration of the surgical procedure. No difference was found in the following PROMs: Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), visual analogue scale (VAS), function and pain subscales of the KSS score. No difference was found in the rate of anterior knee pain, revision, aseptic loosening, fractures, and deep vein thrombosis.Conclusion: There is no evidence in support that MB implants promote greater outcomes compared to FB implants in primary TKA.Level of evidence: Level I.Keywords
Funding Information
- RWTH Aachen University
- RWTH Aachen University
This publication has 119 references indexed in Scilit:
- A randomised controlled clinical trial and gait analysis of fixed- and mobile-bearing total knee replacements with a five-year follow-upThe Journal of Bone and Joint Surgery. British volume, 2012
- The John Insall Award: No Functional Advantage of a Mobile Bearing Posterior Stabilized TKAClinical Orthopaedics and Related Research, 2012
- Functional performance of mobile versus fixed bearing total knee prostheses: a randomised controlled trialKnee Surgery, Sports Traumatology, Arthroscopy, 2011
- Functional outcome of PFC Sigma fixed and rotating-platform total knee arthroplasty. A prospective randomised controlled trialInternational Orthopaedics, 2009
- Early Outcome of TKA with a Medial Pivot Fixed-bearing Prosthesis is Worse than with a PFC Mobile-bearing ProsthesisClinical Orthopaedics and Related Research, 2009
- Patient-reported outcomes after fixed- versus mobile-bearing total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Less Anterior Knee Pain with a Mobile-bearing Prosthesis Compared with a Fixed-bearing ProsthesisClinical Orthopaedics and Related Research, 2008
- Simultaneous mobile- and fixed-bearing total knee replacement in the same patientsThe Journal of Bone and Joint Surgery. British volume, 2007
- A kinematic comparison of fixed- and mobile-bearing knee replacementsThe Journal of Bone and Joint Surgery. British volume, 2006
- Nature of the 5? residue in the M2 domain affects function of the human ?1?1 GABAA receptorSynapse, 1997