Biomechanical analysis of a transiliac internal fixator
Open Access
- 8 April 2011
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (12) , 1863-1868
Abstract
We evaluated the biomechanical characteristics of the transiliac internal fixator (TIFI) as compared to two well-established methods of internal posterior pelvic ring fixation. Six freshly frozen human pelves were used for simulated single-leg stance loading of an AO type C injury model (pubic symphysis diastasis and unilateral sacroiliac joint disruption). The symphysis rupture was stabilized with a dynamic compression plate. Afterwards the three internal stabilization systems (TIFI, iliosacral screws and ventral plate osteosynthesis) were analysed. Fragment movement was measured in a contact-free manner with a stereophotometric infrared system. No significant differences in the three-dimensional deformation tolerated by the TIFI as compared to the other internal fixation systems were found. The transiliac internal fixator provides the same biomechanical stability as the other reference implants tested. We suggest the use of this device as a suitable alternative to the other implants.Keywords
This publication has 29 references indexed in Scilit:
- Treatment of posterior pelvic ring injuries with minimally invasive percutaneous plate osteosynthesisInternational Orthopaedics, 2009
- Percutaneous fixation of the pelvic ringThe Journal of Bone and Joint Surgery. British volume, 2007
- Die hämodynamisch wirksame BeckeninstabilitätZentralblatt fur Chirurgie, 2004
- Functional Outcome of Open Reduction and Internal Fixation for Completely Unstable Pelvic Ring Fractures (Type C)Journal of Orthopaedic Trauma, 2003
- Anatomically correct reduction and fixation of a Tile C-1 type unilateral sacroiliac disruption using a rod and pedicle screw systembetween the S1 vertebra and the ilium: experimental and clinical case reportJournal of Orthopaedic Science, 2002
- Outcome of Operatively Treated Unstable Posterior Pelvic Ring DisruptionsClinical Orthopaedics and Related Research, 1996
- Algorithms for early management of pelvic fracturesInjury, 1996
- The effect of different storage methods on the mechanical properties of trabecular boneJournal of Biomechanics, 1993
- Anterior square-plate fixation of sacroiliac disruption: 2–8 years follow-up of 23 consecutive casesActa Orthopaedica, 1993
- Anterior Approach and Stabilization of the Disrupted Sacroiliac Joint1987