- 1 November 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (11) , 3209-3217
A Minimally Invasive Stabilizing System for Dorsal Pelvic Ring Injuries
L exposure should be considered. We treated these injuries using a transiliac internal fixator (TIFI) in a minimally invasive technique characterized by implantation of a pedicle screw and rod system, bridging the sacroiliac joints and the sacral area. Questions/purposes We asked whether (1) we could achieve anatomic restoration with the device, (2) specific complications were associated with this minimally invasive approach (particularly enhanced intraoperative blood loss, soft tissue complications, and iatrogenic neurovascular damage), and (3) function 3 years after trauma was comparable to that of established methods. Methods We retrospectively reviewed 67 patients with dorsal pelvic injuries during a 7-year period. We evaluated the (1) reduction by grading the maximal displacement measured with three radiographic views, (2) the complications during the observation period, and (3) the function with a validated questionnaire (Pelvic Outcome Score) in all but five patients at least 3 years after trauma (mean, 37 months; range, 36-42 months). Results At last followup we observed a secondary fracture displacement greater than 5 mm in one patient. The intraoperative blood loss was less than 50 mL in all patients. No neurovascular lesions occurred owing to implantation. Four patients had wound infections, one had loosening of a single pedicle screw, and one had an iatrogenic screw malpositioning. Thirty-five of the 62 patients achieved Pelvic Outcome Scores of either a maximum score or 6 of 7 points. Conclusion Our observations suggest TIFI is a reasonable alternative to other established fixation devices for injuries of the dorsal pelvic ring with minor risks of major blood loss or iatrogenic neurovascular damage. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence....
- 1 November 2011
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 469 (11) , 3209-3217
A Minimally Invasive Stabilizing System for Dorsal Pelvic Ring Injuries
L exposure should be considered. We treated these injuries using a transiliac internal fixator (TIFI) in a minimally invasive technique characterized by implantation of a pedicle screw and rod system, bridging the sacroiliac joints and the sacral area. Questions/purposes We asked whether (1) we could achieve anatomic restoration with the device, (2) specific complications were associated with this minimally invasive approach (particularly enhanced intraoperative blood loss, soft tissue complications, and iatrogenic neurovascular damage), and (3) function 3 years after trauma was comparable to that of established methods. Methods We retrospectively reviewed 67 patients with dorsal pelvic injuries during a 7-year period. We evaluated the (1) reduction by grading the maximal displacement measured with three radiographic views, (2) the complications during the observation period, and (3) the function with a validated questionnaire (Pelvic Outcome Score) in all but five patients at least 3 years after trauma (mean, 37 months; range, 36-42 months). Results At last followup we observed a secondary fracture displacement greater than 5 mm in one patient. The intraoperative blood loss was less than 50 mL in all patients. No neurovascular lesions occurred owing to implantation. Four patients had wound infections, one had loosening of a single pedicle screw, and one had an iatrogenic screw malpositioning. Thirty-five of the 62 patients achieved Pelvic Outcome Scores of either a maximum score or 6 of 7 points. Conclusion Our observations suggest TIFI is a reasonable alternative to other established fixation devices for injuries of the dorsal pelvic ring with minor risks of major blood loss or iatrogenic neurovascular damage. Level of Evidence Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence....
- Open Access
- 8 April 2011
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (12) , 1863-1868
Biomechanical analysis of a transiliac internal fixator
We evaluated the biomechanical characteristics of the transiliac internal fixator (TIFI) as compared to two well-established methods of internal posterior pelvic ring fixation. Six freshly frozen human pelves were used for simulated single-leg stance loading of an AO type C injury model (pubic symphysis diastasis and unilateral sacroiliac joint disruption). The symphysis rupture was stabilized with a dynamic compression plate. Afterwards the three internal stabilization systems (TIFI, iliosacral screws and ventral plate osteosynthesis) were analysed. Fragment movement was measured in a contact-free manner with a stereophotometric infrared system. No significant differences in the three-dimensional deformation tolerated by the TIFI as compared to the other internal fixation systems were found. The transiliac internal fixator provides the same biomechanical stability as the other reference implants tested. We suggest the use of this device as a suitable alternative to the other implants.
- 8 April 2011
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (12) , 1863-1868
Open AccessBiomechanical analysis of a transiliac internal fixator
We evaluated the biomechanical characteristics of the transiliac internal fixator (TIFI) as compared to two well-established methods of internal posterior pelvic ring fixation. Six freshly frozen human pelves were used for simulated single-leg stance loading of an AO type C injury model (pubic symphysis diastasis and unilateral sacroiliac joint disruption). The symphysis rupture was stabilized with a dynamic compression plate. Afterwards the three internal stabilization systems (TIFI, iliosacral screws and ventral plate osteosynthesis) were analysed. Fragment movement was measured in a contact-free manner with a stereophotometric infrared system. No significant differences in the three-dimensional deformation tolerated by the TIFI as compared to the other internal fixation systems were found. The transiliac internal fixator provides the same biomechanical stability as the other reference implants tested. We suggest the use of this device as a suitable alternative to the other implants.
- 25 November 2010
- Published by Springer Nature in Bulletin of Experimental Biology and Medicine
- Vol. 150 (1) , 157-159
Resazurin Dye as a Reliable Tool for Determination of Cell Number and Viability in Mesenchymal Stem Cell Culture
Human mesenchymal stem cells are a valuable cell source for tissue engineering. Determination of cell number and viability is crucial. However, this can be tested only at the end of cell culture. This study shows that Resazurin dye staining is a reliable tool for evaluation of cell number and viability in culture without cell perturbation.
- 25 November 2010
- Published by Springer Nature in Bulletin of Experimental Biology and Medicine
- Vol. 150 (1) , 157-159
Resazurin Dye as a Reliable Tool for Determination of Cell Number and Viability in Mesenchymal Stem Cell Culture
Human mesenchymal stem cells are a valuable cell source for tissue engineering. Determination of cell number and viability is crucial. However, this can be tested only at the end of cell culture. This study shows that Resazurin dye staining is a reliable tool for evaluation of cell number and viability in culture without cell perturbation.
- 1 April 2010
- Vol. 76 (2) , 282-5
Asymptomatic dissection of craniocervical arteries in combination with severe cervical spine fractures.
Cervical spine fractures and traumatic dissection of craniocervical arteries are a common combination after severe trauma to the head and neck. Usually, severe symptoms lead the way to diagnosis. We report the case of a young woman involved in a high-velocity car accident without leading neurological symptoms but the threatening combination of dislocation fractures of the C6th/C7th/Th1th vertebrae and dissections of both carotid arteries and one vertebral artery. This case illustrates the need for quick and sufficient clinical diagnostic workup and evaluation and a well-scheduled treatment plan to combine the management of the spinal column fractures and the vascular injury. A review of the relevant literature and therapeutic approaches is presented.
- 1 April 2010
- Vol. 76 (2) , 282-5
Asymptomatic dissection of craniocervical arteries in combination with severe cervical spine fractures.
Cervical spine fractures and traumatic dissection of craniocervical arteries are a common combination after severe trauma to the head and neck. Usually, severe symptoms lead the way to diagnosis. We report the case of a young woman involved in a high-velocity car accident without leading neurological symptoms but the threatening combination of dislocation fractures of the C6th/C7th/Th1th vertebrae and dissections of both carotid arteries and one vertebral artery. This case illustrates the need for quick and sufficient clinical diagnostic workup and evaluation and a well-scheduled treatment plan to combine the management of the spinal column fractures and the vascular injury. A review of the relevant literature and therapeutic approaches is presented.