Delayed perforation of the right ventricle by pacemaker/automated implantable cardioverter-defibrillator lead
Authors:
- Sarvesh KumarSKSarvesh Kumar
- Vivek TewarsonVTVivek Tewarson
- Mohammad Zeeshan HakimMHMohammad Zeeshan Hakim
- Shobhit KumarSKShobhit Kumar
- Sushil K SinghSSSushil K Singh
Open Access
- 1 January 2021
- journal article
- Published by Medknow in Heart India
- Vol. 9 (1) , 35-39
Abstract
Introduction: Cardiac perforation by pacemaker/automatic implantable cardioverter-defibrillator (AICD) lead can be a life-threatening emergency. Delayed cardiac perforation by pacemaker/AICD lead is defined as perforation occurring after a period of 1 month following pacemaker/AICD insertion. Delayed perforation is often difficult to identify at first and needs active intervention to prevent complications and death. Materials and Methods: Patients presenting with and operated upon for delayed cardiac perforation following pacemaker/AICD insertion were included in this study. The study was conducted between April 2019 and April 2020. Results: Three patients reported with delayed cardiac perforation after pacemaker insertion. All patients had syncopal episodes, and detection could be easily done using chest X-ray and trans-thoracic echocardiography (TTE). Two patients had active fixation leads used for anchoring the lead in the right ventricle (RV). Two patients were female, while one was a male, and all had perforation through the RV apex. Lead reposition was done in two cases, thereby preventing the need for placing additional leads, while a new lead was required in the third case. Conclusion: Early identification of cardiac perforation can be done easily with chest X-ray and TTE, but a high index of suspicion should be kept in mind. Surgical or fluoroscopic intervention may be planned depending on the available expertise and patient condition.Keywords
This publication has 10 references indexed in Scilit:
- Minimal Cardiac Perforation by Lead Pacemaker Complicated with Pericardial Effusion and Impending Tamponade: Optimal Management with No Pericardiocentesis Driven by EchocardiographyDiagnostics, 2020
- Percutaneous lead extraction and repositioning: An effective and safe therapeutic strategy for early ventricular lead perforation with dislocation both inside and outside the pericardial sac following a cardiac device implantationJournal of Cardiovascular Electrophysiology, 2018
- Subacute Presentation of Right Ventricular Perforation Due to Pacemaker LeadThe American Journal of Cardiology, 2018
- Identification and management of right ventricular perforation using pacemaker and cardioverter‐defibrillator leads: A case series and mini reviewJournal of Arrhythmia, 2016
- Right ventricular perforation by a passive‐fixation pacemaker lead two weeks after implantationJournal of Arrhythmia, 2014
- Ventricular perforation by pacemaker lead repaired with two hemostatic devicesInternational Journal of Surgery Case Reports, 2014
- Late Perforation by Cardiac Implantable Electronic Device Leads: Clinical Presentation, Diagnostic Clues, and ManagementClinical Cardiology, 2010
- A rare case of late right ventricular perforation by a passive-fixation permanent pacemaker leadEP Europace, 2009
- Late Right Ventricular Perforation After Permanent Pacemaker Implantation: How Far Can the Lead Go?Pacing and Clinical Electrophysiology, 2005
- Value of the unipolar electrogram in the diagnosis of right ventricular perforation following pacemaker implantationHeart, 2005