Use of DSLR and Sonic Cameras to Detect and Locate High-Voltage Corona Discharges
Open Access
Abstract
Corona discharges are a concern in high-voltage applications. It is of utmost importance to detect and locate the discharges at an early stage using simple methods for this purpose. This paper evaluates and compares the sensitivity of two methods for detecting and locating the source of discharges, which are based on a digital single-lens reflex (DSLR) camera and a portable wideband sonic camera incorporating a matrix of micro-electromechanical systems (MEMS) microphones. Both cameras can generate an image of the studied area where the discharge sites are identified. The study is carried out with different electrode geometries, 50 Hz alternating current (ac) and positive and negative direct current (dc) supplies, and the effect of the distance between the sensor and the discharge sites is also analyzed. The presented results show that the sonic camera enables fast, simple, and sensitive detection and localization of the source of corona discharges even at a very early stage in daylight conditions, regardless of the type of power supply, that is, ac or positive/negative dc, and at distance of several meters from the discharge source.Keywords
Funding Information
- Ministerio de Ciencia e Innovación (PID2020-114240RB-I00, 2017 SGR 967)
- Generalitat de Catalunya (PID2020-114240RB-I00, 2017 SGR 967)
This publication has 48 references indexed in Scilit:
- Computation of audible noise from a 1200 kV UHV power transmission lineIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- Experimental investigation of corona onset in contaminated polymer surfacesIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- The correlation between audible noise and corona current in time domain caused by single positive corona source on the conductorIEEE Transactions on Dielectrics and Electrical Insulation, 2015
- Time-domain and frequency-domain characteristics of audible noise from single corona source2014
- Analysis of Ionizing Radiation Generated by Partial DischargesActa Physica Polonica A, 2014
- Linearisation of RGB Camera Responses for Quantitative Image Analysis of Visible and UV Photography: A Comparison of Two TechniquesPLOS ONE, 2013
- Study on Partial Discharge Detection of 10kV XLPE Power CableTELKOMNIKA Indonesian Journal of Electrical Engineering, 2012
- Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging CameraJournal of Institute of Control, Robotics and Systems, 2010
- Partial discharge diagnostics and electrical equipment insulation condition assessmentIEEE Transactions on Dielectrics and Electrical Insulation, 2005
- Comparison between optical and electrical methods for partial discharge measurement2002