  • Open Access

    Evaluation of Pressure Effect on Accelerated Aging Tests of Polymer-Insulated Aircraft Wires

    by Pau Bas-Calopa, Jordi-Roger Riba, Manuel Moreno-Eguilaz

    Most current international standards for qualifying polymer-insulated wires for aircraft applications rely on degradation tests conducted under standard pressure conditions. However, some wires are used in unpressurized areas and therefore need to withstand low-pressure conditions. In the technical literature, there is a shortage of data on this topic. This article focuses on accelerated wet arc tracking tests of insulated wires and evaluates three methods that assess the performance of surface discharges generated during degradation, based on the light emitted, under different pressure conditions in the range of 100 kPa–16 kPa. The experimental results presented in this paper show that the sensitivity of the proposed methods increases with atmospheric pressure, allowing a better quantification of the degradation effects at higher pressures. These results can also help to gain experience and understanding in how commercial optoelectronic sensors can be used to assess the insulation condition by analyzing the light generated by the surface discharges.


  • Experimental Validation of the Adiabatic Assumption of Short-Circuit Tests on Bare Conductors

    by Jordi-Roger Riba, David González, Pau Bas-Calopa, Manuel Moreno-Eguilaz

    According to various international standards, many high-voltage devices must withstand short-circuit tests. Due to the enormous power and current requirements, they have to be tested in very specialized and expensive power laboratories, which are scarce and not affordable for the vast majority of electrical product manufacturers. It is proposed to break the time limit of about one second imposed by the standards by using a lower current to heat for a longer time, requiring more affordable equipment and thus reducing the cost for testing. This work analyzes the limits of the adiabatic assumption in short-circuit tests in order to quantify how the duration of these tests can be extended to reduce the power required and the current applied, while obtaining almost the same results, i.e., the same temperature at the end of the heating phase of the tests. For this purpose, bare cylindrical conductors are analyzed and the temperature dependence of the properties of the conductor material is considered. Experimental and simulation results presented in this paper suggest that by applying this approach, short-circuit tests intended for product design, verification and quality control can be performed in much less demanding and affordable laboratory facilities.


  • Open Access

    Analyzing the Effect of Dynamic Pressure Drop on Corona Discharges for Aircraft Applications

    by Pau Bas-Calopa, Jordi-Roger Riba, Manuel Moreno-Eguilaz

    The combination of the low-pressure environment found in aircraft systems and the gradual electrification of aircraft increases the risk of electrical discharges occurrence. This is an undesirable situation that compromises aircraft safety and complicates maintenance operations. Experimental data are needed to understand this problem. However, most of the published studies are based on static pressure conditions, but aircraft systems are exposed to dynamic pressure conditions, especially during the climb and descent phases of flight. This paper analyzes the effect of dynamic pressure during the climb phase on the corona inception voltage because this phase experiences the worst pressure drop rate. The experimental evidence presented in this paper shows that within the analyzed pressure drop rate range, the dynamic pressure conditions do not have a significant effect on the corona inception value under typical conditions found in aircraft systems during the climb phase.


  • Open Access

    Low-Pressure Optical Detection, Location, and Quantification of Electrical Discharges in Aircraft Wiring Systems

    by Pau Bas-Calopa, Jordi-Roger Riba, Juan Antonio Ortega

    Strict regulations issued by international administrative bodies limit the CO2 equivalent emissions for new aircraft, while increasing efficiency requirements. To reach this goal, next generations of aircraft will use more electrical power than their predecessors, so distribution voltage levels will inevitably increase to limit the weight of the electrical wiring interconnect system (EWIS). However, such increased voltage levels generate higher electric stresses in insulation materials as well as in electric and electronic components; thus new failure modes triggered by electrical discharges will appear, their effects being aggravated by harsh environments typical of aircraft systems. The combined effect of higher electrical stresses, compact designs, and low-pressure operating conditions greatly intensifies the risks of premature insulation failure due to electrical discharge activity. This paper shows that by using image sensors, it is possible to detect, localize, and quantify the intensity of electrical discharges occurring in aircraft environments. Through experiments carried out in a low-pressure chamber using an image sensor, this work detects and determines the intensity of electrical discharges generated in electrical wires in their initial stage, long before major faults develop. This paper also shows that the intensity of the discharges calculated from the digital images obtained with the image sensor is directly proportional to the electrical energy involved in the discharge process and increases linearly with the applied voltage. Due to the difficulty of detecting these failure modes at a very early stage, this strategy could potentially facilitate predictive maintenance tasks while contributing to increased levels of aircraft safety.


  • Open Access

    Use of DSLR and Sonic Cameras to Detect and Locate High-Voltage Corona Discharges

    by Jordi-Roger Riba, Pau Bas-Calopa

    Corona discharges are a concern in high-voltage applications. It is of utmost importance to detect and locate the discharges at an early stage using simple methods for this purpose. This paper evaluates and compares the sensitivity of two methods for detecting and locating the source of discharges, which are based on a digital single-lens reflex (DSLR) camera and a portable wideband sonic camera incorporating a matrix of micro-electromechanical systems (MEMS) microphones. Both cameras can generate an image of the studied area where the discharge sites are identified. The study is carried out with different electrode geometries, 50 Hz alternating current (ac) and positive and negative direct current (dc) supplies, and the effect of the distance between the sensor and the discharge sites is also analyzed. The presented results show that the sonic camera enables fast, simple, and sensitive detection and localization of the source of corona discharges even at a very early stage in daylight conditions, regardless of the type of power supply, that is, ac or positive/negative dc, and at distance of several meters from the discharge source.


  • Open Access

    Using CMOS Image Sensors to Determine the Intensity of Electrical Discharges for Aircraft Applications

    by Jordi-Roger Riba, Pau Bas-Calopa, Yassin Aziz Qolla, Marc Pourraz, Burak Ozsahin

    The development of more electric aircrafts (MEA) and all electric aircrafts (AEA) inevitably implies an increase in electric power and a consequent increase in distribution voltage levels. Increased operating voltages coupled with low pressure in some areas of the aircraft greatly increase the chances of premature insulation failure. Insulation failure manifests itself as surface discharges, arc tracking, arcing, and disruptive or breakdown discharges, in order of increasing severity. Unfortunately, on-board electrical protections cannot detect discharges at an early stage, so other strategies must be explored. In their early stage, insulation faults manifest as surface and corona discharges. They generate optical radiation, mainly in the near-ultraviolet (UV) and visible spectral regions. This paper focuses on a method to detect the discharges, locate the discharge sites, and determine their intensity to facilitate predictive maintenance tasks. It is shown that by using small size and low-cost image sensors, it is possible to detect, locate, and quantify the intensity of the discharges. This paper also proposes and evaluates the behavior of a discharge severity indicator, which is based on determining the intensity of digital images of the discharges, so it can be useful to apply predictive maintenance tasks. The behavior and accuracy of this indicator has been tested in the laboratory using a low-pressure chamber operating in the pressure range of 10–100 kPa, which is characteristic of aircraft applications, analyzing a needle-plane air gap geometry and using an image sensor. The proposed method can be extended to other applications where electrical discharges are an issue.


  • Analysing the influence of geometry and pressure on corona discharges

    by Jordi-Roger Riba, Pau Bas-Calopa, Manuel Moreno-Eguilaz

    In this work, the authors propose an experiment aimed for undergraduate laboratories with the aim of introducing different novelties as a topic for practical sessions or student projects. The topics here investigated are appropriate for students with intermediate physics knowledge. Corona discharges are little studied in regular physics courses despite their practical importance in different areas, such as the distribution and transmission of electrical power, generation of ozone, particulate removal in air conditioning systems, improvement of wettability in polymeric materials, or the removal of electrostatic charges from the surface of airplanes among others. This work analyses the minimum voltage level leading to corona discharges and the influence of geometry and atmospheric pressure because these two factors are the most influential to determine the minimum voltage at which corona discharges appear.


  • Analysing the pressure effect on the contact resistance of electrical connections

    by Jordi-Roger Riba, Pau Bas-Calopa

    We propose an experiment intended for undergraduate laboratories, with the aim to introduce different novelties as a subject for a practical session or students project. We deal with the different components of the resistance in an electrical connection, with special focus on the contact resistance and its dependence with the applied mechanical load or pressure at the interface, since for a fixed geometry and connection materials, the contact pressure has a leading role on the final value of the resistance. The topics analysed are suitable for students with intermediate knowledge of physics. The dependence of the electrical resistance of two metallic rough surfaces with the applied pressure is studied and measured in the laboratory, and the weight of their different components is determined from calculations, simulations and measurements. The pressure dependence of aluminium and copper contacts have been analysed, since they are the most commonly used materials in electrical connections.


  • Open Access

    Measurement of Corona Discharges under Variable Geometry, Frequency and Pressure Environment

    by Pau Bas-Calopa, Jordi-Roger Riba, Manuel Moreno-Eguilaz

    Aeronautical industry is evolving towards more electric aircrafts (MEA), which will require much more electrical power compared to conventional models. To satisfy this increasing power demand and stringent weight requirements, distribution voltages must be raised, which jointly with the low-pressure environment and high operating frequencies increase the risk of electrical discharges occurrence. Therefore, it is important to generate data to design insulation systems for these demanding applications. To this end, in this work a sphere-to-plane electrode configuration is tested for several sphere geometries (diameters ranging from 2 mm to 10 mm), frequencies of 50 Hz, 400 Hz and 800 Hz and pressures in the 20–100 kPa range, to cover most aircraft applications. The corona extinction voltage is experimentally determined by using a gas-filled tube solar blind ultraviolet (UV) sensor. In addition, a CMOS imaging sensor is used to locate the discharge points. Next, to gain further insight to the discharge conditions, the electric field strength is calculated using finite element method (FEM) simulations and fitted to equations based on Peek’s law. The results presented in this paper could be especially valuable to design aircraft electrical insulations as well as for high-voltage hardware manufacturers, since the results allow determining the electric field values at which the components can operate free of surface discharges for a wide altitude range.


  • Open Access

    Corona Discharge Characteristics under Variable Frequency and Pressure Environments

    by Pau Bas-Calopa, Jordi-Roger Riba, Manuel Moreno-Eguilaz

    More electric aircrafts (MEAs) are paving the path to all electric aircrafts (AEAs), which make a much more intensive use of electrical power than conventional aircrafts. Due to the strict weight requirements, both MEA and AEA systems require to increase the distribution voltage in order to limit the required electrical current. Under this paradigm new issues arise, in part due to the voltage rise and in part because of the harsh environments found in aircrafts systems, especially those related to low pressure and high-electric frequency operation. Increased voltage levels, high-operating frequencies, low-pressure environments and reduced distances between wires pose insulation systems at risk, so partial discharges (PDs) and electrical breakdown are more likely to occur. This paper performs an experimental analysis of the effect of low-pressure environments and high-operating frequencies on the visual corona voltage, since corona discharges occurrence is directly related to arc tracking and insulation degradation in wiring systems. To this end, a rod-to-plane electrode configuration is tested in the 20–100 kPa and 50–1000 Hz ranges, these ranges cover most aircraft applications, so that the corona extinction voltage is experimentally determined by using a low-cost high-resolution CMOS imaging sensor which is sensitive to the visible and near ultraviolet (UV) spectra. The imaging sensor locates the discharge points and the intensity of the discharge, offering simplicity and low-cost measurements with high sensitivity. Moreover, to assess the performance of such sensor, the discharges are also acquired by analyzing the leakage current using an inexpensive resistor and a fast oscilloscope. The experimental data presented in this paper can be useful in designing insulation systems for MEA and AEA applications.