Systolic Sac Pressure Index for the Prediction of Persistent Type II Endoleak for 12 Months After Endovascular Abdominal Aortic Aneurysm Repair
- 10 September 2015
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (4) , 522-529
Abstract
Purpose To assess the relationship between the systolic sac pressure index (SPI) and the presence of endoleaks 12 months after endovascular abdominal aortic aneurysm repair (EVAR). Materials and Methods We performed a single-center prospective trial of consecutively treated patients. SPI (calculated as systolic sac pressure/systolic aortic pressure) was measured by catheterization immediately after EVAR. Contrast-enhanced computed tomography was scheduled 12 months after EVAR to detect possible endoleaks. Results Data were available for 34 patients who underwent EVAR for an AAA. Persisting type II endoleak was found in 8 patients (endoleak-positive group) but not in the other 26 patients (endoleak-negative group). The mean ± standard deviation SPI was significantly greater in the endoleak-positive group than in the endoleak-negative group (0.692 ± 0.048 vs. 0.505 ± 0.081, respectively; P = .001). Receiver-operating characteristic curve analysis revealed that an SPI of 0.638 was the optimum cutoff value for predicting a persistent endoleak at 12 months with high accuracy (0.971; 33/34), sensitivity (1.00), and specificity (0.962) values. The mean change in AAA diameter was −4.28 ± 5.03 mm and 2.22 ± 4.54 mm in patients with SPI of P = .002). Conclusion Patients with an SPI of ≥0.638 immediately after EVAR were more likely to have a persistent type II endoleak at 12 months with an accuracy of 0.971, and showed increases in aneurysm sac diameter compared with patients with an SPI of <0.638.Keywords
This publication has 21 references indexed in Scilit:
- Endoleaks after endovascular aneurysm repair lead to nonuniform intra-aneurysm sac pressureJournal of Vascular Surgery, 2007
- Initial results of wireless pressure sensing for endovascular aneurysm repair: The APEX Trial—Acute Pressure Measurement to Confirm Aneurysm Sac EXclusionJournal of Vascular Surgery, 2007
- Sac behavior after aneurysm treatment with the Gore Excluder low-permeability aortic endoprosthesis: 12-month comparison to the original Excluder deviceJournal of Vascular Surgery, 2006
- Abdominal aortic aneurysm sac shrinkage after endovascular aneurysm repair: Correlation with chronic sac pressure measurementJournal of Vascular Surgery, 2006
- A Randomized Trial Comparing Conventional and Endovascular Repair of Abdominal Aortic AneurysmsNew England Journal of Medicine, 2004
- Aneurysm enlargement following endovascular aneurysm repair: AneuRx clinical trialJournal of Vascular Surgery, 2004
- A UK Multi-centre Experience with a Second-generation Endovascular Stent-graft: Results from the Zenith Users GroupEuropean Journal of Vascular and Endovascular Surgery, 2004
- Intra-aneurysm Sac Pressure – The Holy Grail of Endoluminal Grafting of AAAEuropean Journal of Vascular and Endovascular Surgery, 2002
- Abdominal aortic endografting:Journal of the American College of Surgeons, 2002
- Need for secondary interventions after endovascular repair of abdominal aortic aneurysms. Intermediate-term follow-up results of a European collaborative registry (EUROSTAR)British Journal of Surgery, 2000