Tetsuo Sonomura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tetsuo Sonomura has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Akira Ikoma
Department of Radiology, Wakayama Medical University, Wakayama, Japan
13 shared publications - Nobuyuki Kawai
Department of Radiology, Wakayama Medical University, Wakayamashi, Japan
11 shared publications Morio Sato
10 shared publicationsHiroki Minamiguchi
Department of Radiology Wakayama Medical University 811-1 Kimiidera, Wakayamashi, Wakayama 641-8510, Japan
8 shared publications- Motoki Nakai
Department of Radiology, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, Japan
8 shared publications - Hiroki Minamiguchi
Wakayama Medical University
7 shared publications
Latest Publications
- 9 June 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (8) , 1174-1187
Factors that Enhance the Stability of Polidocanol and Monoethanolamine Oleic Acid Foams, and Identification of the Optimal Foam-Creating Device
Purpose To investigate the effects of the air ratio and the addition of glucose solution (Gluc) on the stability of polidocanol-nonionic water-soluble contrast medium (Po/CM) and monoethanolamine oleate-nonionic water-soluble contrast medium (EO/CM) foams, and to identify the optimal device to prepare these foams. Materials and Methods Four sclerosants were used: Po/CM (Po:CM = 1:1), Po/CM-Gluc (Po:CM:70% Gluc = 2:1:1), EO/CM (EO:CM = 1:1), and EO/CM-Gluc (EO:CM:70% Gluc = 2:1:1). The four sclerosants were mixed with air at ratios of 1:4, 1:7, and 1:10 using the Micro Magic connector (MM), hydrophobic emulsifying connector (Hbic), and hydrophilic emulsifying connector (Hlic). The times taken to prepare the foams using each device and the foam half-lives were measured. Results The Po/CM (1:10) and Po/CM-Gluc (1:10) foams could not be prepared using any device. The EO/CM-Gluc (1:10), Po/CM (1:7), and Po/CM-Gluc (1:7) foams could not be prepared using the MM. The times taken to prepare the foams were not significantly different between the Hbic and Hlic for EO/CM-Gluc (1:4) and Po/CM (1:4). The times taken to prepare the other foams decreased significantly in the order MM > Hbic > Hlic. The half-lives of the foams were significantly prolonged by increasing the air ratio. For foams with the same air ratio, the presence of Gluc significantly increased the half-lives of EO/CM and Po/CM compared with the foams without Gluc. Conclusion The half-lives of foams were prolonged by increasing their air ratio and by adding Gluc. Of the tested mixture devices, Hlic created foams with longer half-lives in the shortest time. Graphical abstract
- 9 June 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (8) , 1174-1187
Factors that Enhance the Stability of Polidocanol and Monoethanolamine Oleic Acid Foams, and Identification of the Optimal Foam-Creating Device
Purpose To investigate the effects of the air ratio and the addition of glucose solution (Gluc) on the stability of polidocanol-nonionic water-soluble contrast medium (Po/CM) and monoethanolamine oleate-nonionic water-soluble contrast medium (EO/CM) foams, and to identify the optimal device to prepare these foams. Materials and Methods Four sclerosants were used: Po/CM (Po:CM = 1:1), Po/CM-Gluc (Po:CM:70% Gluc = 2:1:1), EO/CM (EO:CM = 1:1), and EO/CM-Gluc (EO:CM:70% Gluc = 2:1:1). The four sclerosants were mixed with air at ratios of 1:4, 1:7, and 1:10 using the Micro Magic connector (MM), hydrophobic emulsifying connector (Hbic), and hydrophilic emulsifying connector (Hlic). The times taken to prepare the foams using each device and the foam half-lives were measured. Results The Po/CM (1:10) and Po/CM-Gluc (1:10) foams could not be prepared using any device. The EO/CM-Gluc (1:10), Po/CM (1:7), and Po/CM-Gluc (1:7) foams could not be prepared using the MM. The times taken to prepare the foams were not significantly different between the Hbic and Hlic for EO/CM-Gluc (1:4) and Po/CM (1:4). The times taken to prepare the other foams decreased significantly in the order MM > Hbic > Hlic. The half-lives of the foams were significantly prolonged by increasing the air ratio. For foams with the same air ratio, the presence of Gluc significantly increased the half-lives of EO/CM and Po/CM compared with the foams without Gluc. Conclusion The half-lives of foams were prolonged by increasing their air ratio and by adding Gluc. Of the tested mixture devices, Hlic created foams with longer half-lives in the shortest time. Graphical abstract
- 24 October 2023
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (2) , 268-270
Balloon-Assisted Arterial Embolization of Pseudoaneurysms Using NBCA–Lipiodol–Iopamidol Mixture in Two Clinical Cases
- 24 October 2023
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 47 (2) , 268-270
Balloon-Assisted Arterial Embolization of Pseudoaneurysms Using NBCA–Lipiodol–Iopamidol Mixture in Two Clinical Cases
- 21 January 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (3) , 357-364
Determination of the Optimal Ratio and the Relationship Between Viscosity and Adhesion of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol for Balloon-Assisted Embolization of Wide-Neck Aneurysms in Swine
Purpose To determine the optimal ratio of n-butyl cyanoacrylate–Lipiodol–iopamidol (NLI) for balloon-assisted embolization of wide-neck aneurysms in swine. Materials and Methods Sixteen NLI mixtures were prepared for in vitro studies. The viscosity of each mixture was measured for 30 min. We evaluated whether the mixtures could be injected through a microcatheter and whether they adhered to the microcatheter. In vivo, 15 wide-neck aneurysms were created on the arteries in 4 female swine. Under balloon occlusion, 7 aneurysms were embolized with NLI141 (NBCA:Lipidol:iopamidol = 1:4:1) and 8 were embolized with NLI231. We performed angiography to evaluate adhesion of NLI to the balloons or microcatheters and NLI migration. Results In vitro, the iopamidol content needed to comprise at least 1/6 of the mixture in order for NLI to be non-adhesive with increased viscosity. NLI could not be injected through a microcatheter if the iopamidol content exceeded 1/6 of the mixture. Only NLI141 and NLI231 did not adhere to the microcatheter with increased viscosity, and could be injected through a microcatheter. In vivo, neither NLI mixture adhered to the balloons or microcatheters. The migration of NLI was observed in 6 of 7 aneurysms embolized with NLI141 and in none of 8 aneurysms embolized with NLI231. Conclusion Our in vitro study revealed that the ratios of NLI that were non-adhesive and could be injected through a microcatheter were 1:4:1 and 2:3:1. The optimal ratio of NLI for balloon-assisted embolization of wide-neck aneurysms in swine was considered to be 2:3:1.
- 21 January 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (3) , 357-364
Determination of the Optimal Ratio and the Relationship Between Viscosity and Adhesion of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol for Balloon-Assisted Embolization of Wide-Neck Aneurysms in Swine
Purpose To determine the optimal ratio of n-butyl cyanoacrylate–Lipiodol–iopamidol (NLI) for balloon-assisted embolization of wide-neck aneurysms in swine. Materials and Methods Sixteen NLI mixtures were prepared for in vitro studies. The viscosity of each mixture was measured for 30 min. We evaluated whether the mixtures could be injected through a microcatheter and whether they adhered to the microcatheter. In vivo, 15 wide-neck aneurysms were created on the arteries in 4 female swine. Under balloon occlusion, 7 aneurysms were embolized with NLI141 (NBCA:Lipidol:iopamidol = 1:4:1) and 8 were embolized with NLI231. We performed angiography to evaluate adhesion of NLI to the balloons or microcatheters and NLI migration. Results In vitro, the iopamidol content needed to comprise at least 1/6 of the mixture in order for NLI to be non-adhesive with increased viscosity. NLI could not be injected through a microcatheter if the iopamidol content exceeded 1/6 of the mixture. Only NLI141 and NLI231 did not adhere to the microcatheter with increased viscosity, and could be injected through a microcatheter. In vivo, neither NLI mixture adhered to the balloons or microcatheters. The migration of NLI was observed in 6 of 7 aneurysms embolized with NLI141 and in none of 8 aneurysms embolized with NLI231. Conclusion Our in vitro study revealed that the ratios of NLI that were non-adhesive and could be injected through a microcatheter were 1:4:1 and 2:3:1. The optimal ratio of NLI for balloon-assisted embolization of wide-neck aneurysms in swine was considered to be 2:3:1.
- 23 November 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (3) , 482-488
Feasibility and Safety of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol as an Alternative Liquid Embolic Material
Purpose To evaluate the feasibility and safety of n-butyl cyanoacrylate (NBCA)–Lipiodol–Iopamidol (NLI) as a liquid embolic material. Materials and Methods In vitro, the ratio of NLI components was adjusted and the configuration of the mixtures was assessed visually in saline. In vivo, 14 wide-necked aneurysms were created on the common carotid and external iliac arteries of four female swine. Under balloon occlusion, 12 aneurysms were embolized with NLI prepared at a NBCA–Lipidol–Iopamidol ratio of 2:3:1 (NLI231), and two were embolized with NBCA–Lipiodol (NL) prepared at a NBCA–Lipiodol ratio of 1:2 (NL12) as a trial group. We performed angiography to evaluate the effectiveness of embolization and adhesion of the embolic material to the balloons or microcatheters. Results In vitro, NLI231 (33% NBCA) was considered to be the optimal ratio for aneurysm embolization based on its configuration and stability. In vivo, embolization using NLI231 was successful and no adhesion between the embolic material and the balloons or microcatheters was observed in all 12 aneurysms. Embolization with NL12 was impossible in the other two aneurysms due to leakage and adhesion of NL. Conclusion The configuration of NLI changed at each ratio. NLI231 is a feasible and safe liquid embolic material for balloon-assisted embolization of wide-necked aneurysms in swine.
- 23 November 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 44 (3) , 482-488
Feasibility and Safety of n-Butyl Cyanoacrylate–Lipiodol–Iopamidol as an Alternative Liquid Embolic Material
Purpose To evaluate the feasibility and safety of n-butyl cyanoacrylate (NBCA)–Lipiodol–Iopamidol (NLI) as a liquid embolic material. Materials and Methods In vitro, the ratio of NLI components was adjusted and the configuration of the mixtures was assessed visually in saline. In vivo, 14 wide-necked aneurysms were created on the common carotid and external iliac arteries of four female swine. Under balloon occlusion, 12 aneurysms were embolized with NLI prepared at a NBCA–Lipidol–Iopamidol ratio of 2:3:1 (NLI231), and two were embolized with NBCA–Lipiodol (NL) prepared at a NBCA–Lipiodol ratio of 1:2 (NL12) as a trial group. We performed angiography to evaluate the effectiveness of embolization and adhesion of the embolic material to the balloons or microcatheters. Results In vitro, NLI231 (33% NBCA) was considered to be the optimal ratio for aneurysm embolization based on its configuration and stability. In vivo, embolization using NLI231 was successful and no adhesion between the embolic material and the balloons or microcatheters was observed in all 12 aneurysms. Embolization with NL12 was impossible in the other two aneurysms due to leakage and adhesion of NL. Conclusion The configuration of NLI changed at each ratio. NLI231 is a feasible and safe liquid embolic material for balloon-assisted embolization of wide-necked aneurysms in swine.
- 16 July 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (10) , 1540-1547
Balloon-Assisted Embolization of Wide-Neck Aneurysms Using a Mixture of n-Butyl Cyanoacrylate, Lipiodol, and Ethanol in Swine: A Comparison of Four n-Butyl Cyanoacrylate Concentrations
Purpose To determine the optimal ratio of n-butyl cyanoacrylate (NBCA)–Lipiodol–ethanol (NLE) mixture for balloon-assisted embolization of wide-neck aneurysms. Materials and methods We created 32 wide-neck aneurysms on both the common carotid arteries and external iliac arteries in eight female swine. Eight aneurysms were randomly assigned to four groups. Under balloon occlusion, the aneurysms were packed using NLE at one of four ratios of NLE: 2:2:1 (NLE221; 40%NBCA); 3:6:1 (NLE361; 30%NBCA); 2:7:1 (NLE271; 20%NBCA); and 1:5:1 (NLE151; 14.3%NBCA). We performed angiography before and after embolization to assess the aneurysms, and we compared adhesion between NLE and the balloon and assessed NLE migration. Three days after embolization, the aneurysms were removed for histopathologic evaluation. Results Embolization was performed in 27 aneurysms. Adhesion between NLE and the balloon was not observed in any group. NLE migration was found in 0/7 aneurysms in the NLE221 group, 0/6 in the NLE361 group, 5/6 in the NLE271 group, and 7/8 in the NLE151 group. NLE migration was significantly lower in the NLE221 group than in the NLE271 and NLE151 groups (P = 0.0047 and 0.0014, respectively) and was significantly lower in the NLE361 group than in the NLE271 and NLE151 groups (P = 0.0152 and 0.0047, respectively). Media necrosis of the arterial wall close to the aneurysms was observed in all groups. Conclusion NLE with an NBCA concentration of ≥ 30% is a safe and feasible embolic material for balloon-assisted embolization of wide-neck aneurysms in swine in the short term up to 3 days after embolization.
- 16 July 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (10) , 1540-1547
Balloon-Assisted Embolization of Wide-Neck Aneurysms Using a Mixture of n-Butyl Cyanoacrylate, Lipiodol, and Ethanol in Swine: A Comparison of Four n-Butyl Cyanoacrylate Concentrations
Purpose To determine the optimal ratio of n-butyl cyanoacrylate (NBCA)–Lipiodol–ethanol (NLE) mixture for balloon-assisted embolization of wide-neck aneurysms. Materials and methods We created 32 wide-neck aneurysms on both the common carotid arteries and external iliac arteries in eight female swine. Eight aneurysms were randomly assigned to four groups. Under balloon occlusion, the aneurysms were packed using NLE at one of four ratios of NLE: 2:2:1 (NLE221; 40%NBCA); 3:6:1 (NLE361; 30%NBCA); 2:7:1 (NLE271; 20%NBCA); and 1:5:1 (NLE151; 14.3%NBCA). We performed angiography before and after embolization to assess the aneurysms, and we compared adhesion between NLE and the balloon and assessed NLE migration. Three days after embolization, the aneurysms were removed for histopathologic evaluation. Results Embolization was performed in 27 aneurysms. Adhesion between NLE and the balloon was not observed in any group. NLE migration was found in 0/7 aneurysms in the NLE221 group, 0/6 in the NLE361 group, 5/6 in the NLE271 group, and 7/8 in the NLE151 group. NLE migration was significantly lower in the NLE221 group than in the NLE271 and NLE151 groups (P = 0.0047 and 0.0014, respectively) and was significantly lower in the NLE361 group than in the NLE271 and NLE151 groups (P = 0.0152 and 0.0047, respectively). Media necrosis of the arterial wall close to the aneurysms was observed in all groups. Conclusion NLE with an NBCA concentration of ≥ 30% is a safe and feasible embolic material for balloon-assisted embolization of wide-neck aneurysms in swine in the short term up to 3 days after embolization.
- Open Access
- 1 January 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (1) , 23
Utility of Contrast-Enhanced Harmonic Endoscopic Ultrasonography for Early Diagnosis of Small Pancreatic Cancer
This study aimed to assess whether contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS), compared to multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI), is useful for early diagnosis of small pancreatic cancer (PC). Between March 2010 and June 2018, all three imaging modalities and surgery were performed for patients with a pancreatic solid lesion measuring ≤20 mm; diagnostic ability was compared among modalities. Fifty-one of 60 patients were diagnosed with PC (PC size in 41 patients: 11–20 mm; 10 patients: ≤10 mm). The sensitivity, specificity, and accuracy of CH-EUS, MDCT, and MRI for PC (11–20 mm) detection were 95%/83%/94%, 78%/83%/79%, and 73%/33%/68%, respectively. The diagnostic ability of CH-EUS was significantly superior compared with MDCT and MRI (p = 0.002 and p = 0.007, respectively). The sensitivity, specificity, and accuracy of CH-EUS, MDCT, and MRI for PC (≤10 mm) detection were 70%/100%/77%, 20%/100%/38%, and 50%/100%/62%, respectively. The diagnostic ability of CH-EUS tended to be superior to that of MDCT (p = 0.025). The sensitivity of MDCT for PC (≤10 mm) detection was significantly lower than that for PC (11–20 mm) detection (20% vs. 78%; p = 0.001). CH-EUS, compared to MDCT and MRI, is useful for diagnosing small PCs.
- 1 January 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (1) , 23
Open AccessUtility of Contrast-Enhanced Harmonic Endoscopic Ultrasonography for Early Diagnosis of Small Pancreatic Cancer
This study aimed to assess whether contrast-enhanced harmonic endoscopic ultrasonography (CH-EUS), compared to multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI), is useful for early diagnosis of small pancreatic cancer (PC). Between March 2010 and June 2018, all three imaging modalities and surgery were performed for patients with a pancreatic solid lesion measuring ≤20 mm; diagnostic ability was compared among modalities. Fifty-one of 60 patients were diagnosed with PC (PC size in 41 patients: 11–20 mm; 10 patients: ≤10 mm). The sensitivity, specificity, and accuracy of CH-EUS, MDCT, and MRI for PC (11–20 mm) detection were 95%/83%/94%, 78%/83%/79%, and 73%/33%/68%, respectively. The diagnostic ability of CH-EUS was significantly superior compared with MDCT and MRI (p = 0.002 and p = 0.007, respectively). The sensitivity, specificity, and accuracy of CH-EUS, MDCT, and MRI for PC (≤10 mm) detection were 70%/100%/77%, 20%/100%/38%, and 50%/100%/62%, respectively. The diagnostic ability of CH-EUS tended to be superior to that of MDCT (p = 0.025). The sensitivity of MDCT for PC (≤10 mm) detection was significantly lower than that for PC (11–20 mm) detection (20% vs. 78%; p = 0.001). CH-EUS, compared to MDCT and MRI, is useful for diagnosing small PCs.
- 1 January 2017
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 28 (1) , 156-157
Transcatheter Embolization of an Internal Mammary Artery-to-Pulmonary Artery Fistula Using N-Butyl Cyanoacrylate and Temporary Dual-Balloon Occlusion
- 1 January 2017
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 28 (1) , 156-157
Transcatheter Embolization of an Internal Mammary Artery-to-Pulmonary Artery Fistula Using N-Butyl Cyanoacrylate and Temporary Dual-Balloon Occlusion
- 10 September 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (4) , 522-529
Systolic Sac Pressure Index for the Prediction of Persistent Type II Endoleak for 12 Months After Endovascular Abdominal Aortic Aneurysm Repair
Purpose To assess the relationship between the systolic sac pressure index (SPI) and the presence of endoleaks 12 months after endovascular abdominal aortic aneurysm repair (EVAR). Materials and Methods We performed a single-center prospective trial of consecutively treated patients. SPI (calculated as systolic sac pressure/systolic aortic pressure) was measured by catheterization immediately after EVAR. Contrast-enhanced computed tomography was scheduled 12 months after EVAR to detect possible endoleaks. Results Data were available for 34 patients who underwent EVAR for an AAA. Persisting type II endoleak was found in 8 patients (endoleak-positive group) but not in the other 26 patients (endoleak-negative group). The mean ± standard deviation SPI was significantly greater in the endoleak-positive group than in the endoleak-negative group (0.692 ± 0.048 vs. 0.505 ± 0.081, respectively; P = .001). Receiver-operating characteristic curve analysis revealed that an SPI of 0.638 was the optimum cutoff value for predicting a persistent endoleak at 12 months with high accuracy (0.971; 33/34), sensitivity (1.00), and specificity (0.962) values. The mean change in AAA diameter was −4.28 ± 5.03 mm and 2.22 ± 4.54 mm in patients with SPI of P = .002). Conclusion Patients with an SPI of ≥0.638 immediately after EVAR were more likely to have a persistent type II endoleak at 12 months with an accuracy of 0.971, and showed increases in aneurysm sac diameter compared with patients with an SPI of <0.638.
- 10 September 2015
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 39 (4) , 522-529
Systolic Sac Pressure Index for the Prediction of Persistent Type II Endoleak for 12 Months After Endovascular Abdominal Aortic Aneurysm Repair
Purpose To assess the relationship between the systolic sac pressure index (SPI) and the presence of endoleaks 12 months after endovascular abdominal aortic aneurysm repair (EVAR). Materials and Methods We performed a single-center prospective trial of consecutively treated patients. SPI (calculated as systolic sac pressure/systolic aortic pressure) was measured by catheterization immediately after EVAR. Contrast-enhanced computed tomography was scheduled 12 months after EVAR to detect possible endoleaks. Results Data were available for 34 patients who underwent EVAR for an AAA. Persisting type II endoleak was found in 8 patients (endoleak-positive group) but not in the other 26 patients (endoleak-negative group). The mean ± standard deviation SPI was significantly greater in the endoleak-positive group than in the endoleak-negative group (0.692 ± 0.048 vs. 0.505 ± 0.081, respectively; P = .001). Receiver-operating characteristic curve analysis revealed that an SPI of 0.638 was the optimum cutoff value for predicting a persistent endoleak at 12 months with high accuracy (0.971; 33/34), sensitivity (1.00), and specificity (0.962) values. The mean change in AAA diameter was −4.28 ± 5.03 mm and 2.22 ± 4.54 mm in patients with SPI of P = .002). Conclusion Patients with an SPI of ≥0.638 immediately after EVAR were more likely to have a persistent type II endoleak at 12 months with an accuracy of 0.971, and showed increases in aneurysm sac diameter compared with patients with an SPI of <0.638.
- 4 July 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (8) , 517-522
Balloon-assisted packing of wide-neck aneurysms with a mixture of n-butyl cyanoacrylate, Lipiodol, and ethanol: an experimental study
To evaluate the feasibility of balloon-assisted packing with a mixture of n-butyl cyanoacrylate (NBCA), Lipiodol, and ethanol for wide-neck aneurysms. Of 10 carotid aneurysms with wide necks created in a swine model, 3 aneurysms (long and short diameters 10.9 × 9.8 mm; neck width 8.3 ± 1.2 mm (mean ± SD)) and 7 aneurysms (11.2 × 9.5 mm; neck width 8.3 ± 1.4 mm) were packed with a mixture of NBCA, Lipiodol, and ethanol in the ratios 1:1:0 (NL11) and 1:1:2 (NLE112), respectively. A microcatheter was advanced into the aneurysm and a balloon catheter was inflated at the aneurysm neck. Ten minutes after injection, the balloon catheter was deflated and its removal was attempted. For all three aneurysms in the NL11 group, the balloon catheter and the microcatheter adhered strongly to the vessel and could not be adjusted. For all seven aneurysms in the NLE112 group, both the balloon catheter and the microcatheter could be easily removed, which enabled successful full packing of the aneurysm by re-advancing the microcatheter and re-injecting NLE112 after re-inflation of the balloon catheter. Although at a preliminary stage, balloon-assisted NLE injection is feasible for packing a wide-neck aneurysm.
- 4 July 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (8) , 517-522
Balloon-assisted packing of wide-neck aneurysms with a mixture of n-butyl cyanoacrylate, Lipiodol, and ethanol: an experimental study
To evaluate the feasibility of balloon-assisted packing with a mixture of n-butyl cyanoacrylate (NBCA), Lipiodol, and ethanol for wide-neck aneurysms. Of 10 carotid aneurysms with wide necks created in a swine model, 3 aneurysms (long and short diameters 10.9 × 9.8 mm; neck width 8.3 ± 1.2 mm (mean ± SD)) and 7 aneurysms (11.2 × 9.5 mm; neck width 8.3 ± 1.4 mm) were packed with a mixture of NBCA, Lipiodol, and ethanol in the ratios 1:1:0 (NL11) and 1:1:2 (NLE112), respectively. A microcatheter was advanced into the aneurysm and a balloon catheter was inflated at the aneurysm neck. Ten minutes after injection, the balloon catheter was deflated and its removal was attempted. For all three aneurysms in the NL11 group, the balloon catheter and the microcatheter adhered strongly to the vessel and could not be adjusted. For all seven aneurysms in the NLE112 group, both the balloon catheter and the microcatheter could be easily removed, which enabled successful full packing of the aneurysm by re-advancing the microcatheter and re-injecting NLE112 after re-inflation of the balloon catheter. Although at a preliminary stage, balloon-assisted NLE injection is feasible for packing a wide-neck aneurysm.
- 12 May 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (7) , 404-409
Effect of transcatheter arterial embolization with a mixture of n-butyl cyanoacrylate, lipiodol, and ethanol on the vascular wall: macroscopic and microscopic studies
To compare the pathologic effect of a mixture of n-butyl cyanoacrylate (NBCA), lipiodol, and ethanol (NLE) with a mixture of NBCA and lipiodol (NL) on the embolized vascular wall. Embolization was performed using four swine with NBCA and lipiodol in a volume ratio of 1:1 (NL11group) in the common hepatic artery (n = 1) and the internal iliac artery (n = 2); and with NBCA, lipiodol, and ethanol in a volume ratio of 1:1:2 (NLE112 group) in the common hepatic artery (n = 3) and the internal iliac artery (n = 6). NL11 casts had an intricate appearance in reticular configuration with red thrombus, while NLE112 casts presented in a single round configuration with surrounding ring-like red thrombus. Desquamation of endothelial cells and infiltration of neutrophils into the adventitial layer were found in all embolized vessels in both groups. Infiltration of neutrophils into the intermediate layer was found in the NL11 group but not in the NLE112 group. The damage to the vascular wall caused by NLE112 was milder than that by NL11, implying the adverse effects of NLE112 are within tolerable limits.
- 12 May 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (7) , 404-409
Effect of transcatheter arterial embolization with a mixture of n-butyl cyanoacrylate, lipiodol, and ethanol on the vascular wall: macroscopic and microscopic studies
To compare the pathologic effect of a mixture of n-butyl cyanoacrylate (NBCA), lipiodol, and ethanol (NLE) with a mixture of NBCA and lipiodol (NL) on the embolized vascular wall. Embolization was performed using four swine with NBCA and lipiodol in a volume ratio of 1:1 (NL11group) in the common hepatic artery (n = 1) and the internal iliac artery (n = 2); and with NBCA, lipiodol, and ethanol in a volume ratio of 1:1:2 (NLE112 group) in the common hepatic artery (n = 3) and the internal iliac artery (n = 6). NL11 casts had an intricate appearance in reticular configuration with red thrombus, while NLE112 casts presented in a single round configuration with surrounding ring-like red thrombus. Desquamation of endothelial cells and infiltration of neutrophils into the adventitial layer were found in all embolized vessels in both groups. Infiltration of neutrophils into the intermediate layer was found in the NL11 group but not in the NLE112 group. The damage to the vascular wall caused by NLE112 was milder than that by NL11, implying the adverse effects of NLE112 are within tolerable limits.