Defining the parameters of a power transmission line equivalent circuit on the basis of phasor measurements
Authors:
Open Access
- 11 July 2017
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012012
Abstract
Power system control is based on employing its computational model, the backbone of which is an equivalent circuit. The equivalent circuit is involved in solving the problems of steady-state computation and analysis, state estimation, transient analysis etc. Its elements parameters are generally defined by the corresponding equipment reference data or datasheets. Although considered to be constant, these parameters depend upon the element actual load, weather conditions and other factors. Consequently, the results of the outlined problems may be subject to significant bias due to the difference between the reference and the actual elements parameters. Hence the task of identifying the actual equivalent circuit parameters is of paramount importance. In terms of power system control the actual measurements are to be used in order to provide the relevant information on the considered power system component state. As for the transmission lines, the state measurements must include the currents and voltages at both ends of the line regarding the Π-shaped equivalent circuit. That said, at present time the equivalent circuit parameters might be defined involving modern systems of phasor measurements (WAMS) on a real-time basis. The method of defining the equivalent circuit parameters based on phasor measurements along with general relations between power system state parameters is proposed. It should be noted as well that while dealing with the actual WAMS data obtained from power system the measurement errors influence the results quite substantially.Keywords
This publication has 8 references indexed in Scilit:
- The flexible algorithm for identifying a disturbance and transient duration in power systems2016
- Impact of technical losses calculation method on bad data validation on the basis of a posteriori analysis2016
- Estimating the instantaneous values of the state parameters during electromechanical transients2015
- Bad data validation on the basis of a posteriori analysis2014
- Implementation of power system model identification for locating in-phase generators2012
- Identification of short transmission-line parameters from synchrophasor measurements2008
- A study on the on-line measurement of transmission line impedances for improved relaying protectionInternational Journal of Electrical Power & Energy Systems, 2006
- Reliability of transmission by means of line impedance and k-Factor measurement2005