P. Y. Kovalenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P. Y. Kovalenko has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
A S Berdin
Automated Electrical Systems Department, Ural Federal University named after the first President of Russia B.N. Yeltsin. 19 Mira St., Yekaterinburg, Russia
1 shared publicationA. S. Berdin
Department of Automated Electrical Systems, Boris Yeltsin Ural Federal University, Ekaterinburg, Russia
1 shared publication- Alexander N. Moiseichenkov
Electrical machines department, Ural Federal University named after the first president of Russia B.N. Yeltsin, Yekaterinburg, Russia
1 shared publication Y. P. Zakharov
Department of Automated Electrical Systems, Boris Yeltsin Ural Federal University, Ekaterinburg, Russia
1 shared publication
Latest Publications
- Open Access
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012012
Defining the parameters of a power transmission line equivalent circuit on the basis of phasor measurements
Power system control is based on employing its computational model, the backbone of which is an equivalent circuit. The equivalent circuit is involved in solving the problems of steady-state computation and analysis, state estimation, transient analysis etc. Its elements parameters are generally defined by the corresponding equipment reference data or datasheets. Although considered to be constant, these parameters depend upon the element actual load, weather conditions and other factors. Consequently, the results of the outlined problems may be subject to significant bias due to the difference between the reference and the actual elements parameters. Hence the task of identifying the actual equivalent circuit parameters is of paramount importance. In terms of power system control the actual measurements are to be used in order to provide the relevant information on the considered power system component state. As for the transmission lines, the state measurements must include the currents and voltages at both ends of the line regarding the Π-shaped equivalent circuit. That said, at present time the equivalent circuit parameters might be defined involving modern systems of phasor measurements (WAMS) on a real-time basis. The method of defining the equivalent circuit parameters based on phasor measurements along with general relations between power system state parameters is proposed. It should be noted as well that while dealing with the actual WAMS data obtained from power system the measurement errors influence the results quite substantially.
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012012
Open AccessDefining the parameters of a power transmission line equivalent circuit on the basis of phasor measurements
Power system control is based on employing its computational model, the backbone of which is an equivalent circuit. The equivalent circuit is involved in solving the problems of steady-state computation and analysis, state estimation, transient analysis etc. Its elements parameters are generally defined by the corresponding equipment reference data or datasheets. Although considered to be constant, these parameters depend upon the element actual load, weather conditions and other factors. Consequently, the results of the outlined problems may be subject to significant bias due to the difference between the reference and the actual elements parameters. Hence the task of identifying the actual equivalent circuit parameters is of paramount importance. In terms of power system control the actual measurements are to be used in order to provide the relevant information on the considered power system component state. As for the transmission lines, the state measurements must include the currents and voltages at both ends of the line regarding the Π-shaped equivalent circuit. That said, at present time the equivalent circuit parameters might be defined involving modern systems of phasor measurements (WAMS) on a real-time basis. The method of defining the equivalent circuit parameters based on phasor measurements along with general relations between power system state parameters is proposed. It should be noted as well that while dealing with the actual WAMS data obtained from power system the measurement errors influence the results quite substantially.
- Open Access
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012013
Comparing the techniques of defining the synchronous machine load angle
The low-frequency oscillations are natural for power systems and may arise due to both small variations of load and large disturbance. The effect of slight load changes may significantly differ for cases of low-magnitude permanent oscillations, which may be considered acceptable, and unstable oscillations, which may lead to a major system emergency. The existing trend of increasing the capacity of long-range power transmission has led to the situation where inter-area oscillations may appear underdamped or even rising in terms of magnitude. Effective oscillations detection with the corresponding countermeasures along with eliminating the prerequisites leading to the oscillations is a guarantee of minimizing their negative consequences. Therefore, it is of crucial importance to perform continuous monitoring which is to provide the information on the "source" of oscillations – a generator or a group of generators, which do not contribute to the oscillations damping or even support their development. The algorithm of quantitative estimation of synchronous generators participation in low-frequency oscillations damping based on synchronized phasor measurements has been proposed previously. It implies utilizing the concept of synchronizing power as a measure of the capability of the machine to maintain synchronous operation. The load angle of the generator is necessary to define the value of the synchronizing power and since the direct measurement of the load angle is generally not available the techniques of its derivation have been developed. The comparison of these techniques is presented with the estimation of the adopted assumptions effect on the synchronizing power evaluation results.
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012013
Open AccessComparing the techniques of defining the synchronous machine load angle
The low-frequency oscillations are natural for power systems and may arise due to both small variations of load and large disturbance. The effect of slight load changes may significantly differ for cases of low-magnitude permanent oscillations, which may be considered acceptable, and unstable oscillations, which may lead to a major system emergency. The existing trend of increasing the capacity of long-range power transmission has led to the situation where inter-area oscillations may appear underdamped or even rising in terms of magnitude. Effective oscillations detection with the corresponding countermeasures along with eliminating the prerequisites leading to the oscillations is a guarantee of minimizing their negative consequences. Therefore, it is of crucial importance to perform continuous monitoring which is to provide the information on the "source" of oscillations – a generator or a group of generators, which do not contribute to the oscillations damping or even support their development. The algorithm of quantitative estimation of synchronous generators participation in low-frequency oscillations damping based on synchronized phasor measurements has been proposed previously. It implies utilizing the concept of synchronizing power as a measure of the capability of the machine to maintain synchronous operation. The load angle of the generator is necessary to define the value of the synchronizing power and since the direct measurement of the load angle is generally not available the techniques of its derivation have been developed. The comparison of these techniques is presented with the estimation of the adopted assumptions effect on the synchronizing power evaluation results.
- Open Access
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012011
WAMS measurements pre-processing for detecting low-frequency oscillations in power systems
Processing the data received from measurement systems implies the situation when one or more registered values stand apart from the sample collection. These values are referred to as "outliers". The processing results may be influenced significantly by the presence of those in the data sample under consideration. In order to ensure the accuracy of low-frequency oscillations detection in power systems the corresponding algorithm has been developed for the outliers detection and elimination. The algorithm is based on the concept of the irregular component of measurement signal. This component comprises measurement errors and is assumed to be Gauss-distributed random. The median filtering is employed to detect the values lying outside the range of the normally distributed measurement error on the basis of a 3σ criterion. The algorithm has been validated involving simulated signals and WAMS data as well.
- 11 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 870 (1) , 012011
Open AccessWAMS measurements pre-processing for detecting low-frequency oscillations in power systems
Processing the data received from measurement systems implies the situation when one or more registered values stand apart from the sample collection. These values are referred to as "outliers". The processing results may be influenced significantly by the presence of those in the data sample under consideration. In order to ensure the accuracy of low-frequency oscillations detection in power systems the corresponding algorithm has been developed for the outliers detection and elimination. The algorithm is based on the concept of the irregular component of measurement signal. This component comprises measurement errors and is assumed to be Gauss-distributed random. The median filtering is employed to detect the values lying outside the range of the normally distributed measurement error on the basis of a 3σ criterion. The algorithm has been validated involving simulated signals and WAMS data as well.
- 23 April 2014
- Published by WITPRESS LTD.
- Vol. 190, 319-325
Estimation of synchronous generator participation in low-frequency oscillations damping based on synchronized phasor measurements
- 23 April 2014
- Published by WITPRESS LTD.
- Vol. 190, 319-325
Estimation of synchronous generator participation in low-frequency oscillations damping based on synchronized phasor measurements