Could larger diameter of 4th generation ceramic bearing increase the rate of squeaking after THA?
Open Access
- 1 December 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (52) , e13977
Abstract
The present study aimed to evaluate the clinical outcomes and bearing-specific complications in a single center of 135 delta ceramic-on-ceramic (COC) total hip arthroplasties (THAs) and explore the occurrence rate of squeaking in 4th generation COC THAs and collate the risk factors for squeaking. We retrospectively analyzed consecutive cohorts of 127 patients (135 hips) who had primary THA with delta COC bearings in our hospital between April 2010 and April 2012. Preoperative Harris hip score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and University of California Los Angeles (UCLA) activity score were evaluated preoperatively and postoperatively. We also evaluated ceramic fracture, squeak, mid-term results, and survival. In our study, the final patient final follow-up date was July 31, 2016. The mean preoperative HHS improved from 39.5 to 93.1 points. Mean preoperative UCLA score was 3.2 points, improving to 8.2 points. The mean preoperative total WOMAC score was 55.5 points and the mean total WOMAC score was 13.3 points at the final follow-up. The Kaplan–Meier survival plot of revision for any reason as the end point was 98.5% and survival with ceramic fracture as the end point was 99.2% at a mean of 70 months’ follow-up. One post-operative ceramic liner rim fracture occurred at 50 months after surgery. Thirteen of the 135 hips produced a squeaking sound. There were no significant differences in gender (P = .56), age (P = .20), body mass index (BMI) (P = .11), diagnosis (P = .46), cup inclination (P = .36), or cup anteversion (P = 1.0) between the squeaking and non-squeaking groups. However, the incidence of squeaking in the 36 mm COC femoral head bearings was higher than in the 28 mm size (13.6% vs 2.1%, P = .033). The 4th generation COC bearing performed well and provides an encouraging rate of survival with no osteolysis or loosening. However, we found that a squeaking sound associated with use of the delta ceramic occurred at a rate of 9.6%, with the larger-diameter heads having significantly higher incidence.Keywords
This publication has 29 references indexed in Scilit:
- The incidence of noise generation arising from the large-diameter Delta Motion ceramic total hip bearingThe Bone & Joint Journal, 2013
- Large-diameter Delta Ceramic-on-ceramic Versus Common-sized Ceramic-on-polyethylene Bearings in THAOrthopedics, 2012
- A comparison of a conventionalversusa short, anatomical metaphyseal-fitting cementless femoral stem in the treatment of patients with a fracture of the femoral neckThe Journal of Bone and Joint Surgery. British volume, 2012
- Fracture of a Titanium Sleeve-encased Third-generation Ceramic Liner in a Modern THA2011
- Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosisInternational Orthopaedics, 2009
- The Squeaking Hip: A Phenomenon of Ceramic-on-Ceramic Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2009
- Ceramic-on-Ceramic Total Hip Arthroplasty: UpdateThe Journal of Arthroplasty, 2008
- High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic BearingsClinical Orthopaedics and Related Research, 2008
- Isolated Fracture of the Ceramic Head After Third-Generation Alumina-on-Alumina Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2008
- Cementless Alumina-on-Alumina Total Hip Arthroplasty in Patients Younger Than 50 Years: A 5-year Minimum Follow-Up StudyThe Journal of Arthroplasty, 2007