High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic Bearings
- 1 June 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 466 (6) , 1438-1443
Abstract
Nt 43 ceramic-on-ceramic noncemented THAs during the time of the study. Squeaking, defined as a reproducible sound of squeaking, clicking, or grating, occurred in nine of 43 implants (20.9%). Standard radiographs were normal. We used CT imaging to determine cup anteversion and inclination angles, comparing the squeaking hips with those of a randomly selected control group, but found no differences. We then hypothesized specific design features (stem size, cup size, head size, and neck length of the head) would be risk factors for squeaking. We found a difference in neck length between squeaking and nonsqueaking implants. A neck length of -4 mm or shorter resulted in a relative risk of 5.56 (95% confidence interval, 1.14-27.01) for squeaking. We found a high incidence of squeaking in our population, and we believe this phenomenon is an underreported side effect of these types of bearings. A short neck length of the femoral implant was a risk factor for squeaking in ceramic-on-ceramic THA. Level of Evidence: Level III, therapeutic study....Keywords
This publication has 26 references indexed in Scilit:
- The Role of Stripe Wear in Causing Acoustic Emissions From Alumina Ceramic-On-Ceramic BearingsThe Journal of Arthroplasty, 2007
- Squeaking in Ceramic-on-Ceramic HipsThe Journal of Arthroplasty, 2007
- The Significance of Metal Staining on Alumina Femoral Heads in Total Hip ArthroplastyThe Journal of Arthroplasty, 2007
- Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurementEuropean Journal of Radiology, 2006
- Alumina Ceramic Bearings for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2005
- Wear analysis of retrieved ceramic‐on‐ceramic articulations in total hip arthroplasty: Femoral head makes contact with the rim of the socket outside of the bearing surfaceJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- Ceramics in Total Hip ReplacementClinical Orthopaedics and Related Research, 2005
- Long‐term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparationJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2003
- Case reports - Fracture of a ceramic acetabular insert after ceramic-onceramic THA–a case reportActa Orthopaedica, 2003
- Number of Polyethylene Particles and Osteolysis in Total Joing Replacements: A Quanatitive Study Using a Tissue-Digestion MethodThe Journal of Bone and Joint Surgery. British volume, 1997