Development and Characterisation of a Microneedle Sensor for Intrapartum Fetal Monitoring
Open Access
- 8 August 2025
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 15 (8) , 517
Abstract
This study presents the in vitro and preliminary ex vivo development of a novel microneedle-based pH sensor for continuous intrapartum fetal monitoring. The objective was to evaluate the feasibility of using microneedle sensors to monitor fetal pH during labour and to develop a proof-of-principle microneedle pH sensor that meets clinical requirements such as high sensitivity to small pH changes (0.05 units) within a relevant range (6.50–7.45), minimal tissue disruption, and a compact design suitable for transcervical placement on the fetal scalp (2 = 0.946, accuracy = 97.65%) and −63.2 mV/pH (R2 = 0.910, accuracy = 93.70%) in the external and internal configurations, respectively. In ISF, a slope of −25.5 mV/pH (R2 = 0.979) was obtained. Ex vivo testing on human skin confirmed successful microneedle penetration without visible iridium oxide transfer or tissue damage, as indicated by methylene blue staining. These findings support the potential for continuous minimally invasive fetal pH monitoring during labour, representing a significant step toward more objective and specific intrapartum assessment.Keywords
Funding Information
- Insight Research Ireland Centre for Data Analytics (12/RC/2289-P2, 825549, CF/2012/2339)
- European Regional Development Fund (12/RC/2289-P2, 825549, CF/2012/2339)
- Enterprise Ireland (12/RC/2289-P2, 825549, CF/2012/2339)
- Higher Education Authority (12/RC/2289-P2, 825549, CF/2012/2339)
This publication has 69 references indexed in Scilit:
- Minimally‐invasive Microneedle‐based Biosensor Array for Simultaneous Lactate and Glucose Monitoring in Artificial Interstitial FluidElectroanalysis, 2019
- Electrodeposited IrO2/Ti electrodes as durable and cost-effective anodes in high-temperature polymer-membrane-electrolyte water electrolyzersApplied Catalysis B: Environment and Energy, 2018
- Microneedle-based drug and vaccine delivery via nanoporous microneedle arraysDrug Delivery and Translational Research, 2015
- Handbook of Reference Electrodes2013
- Fabrication of a microfluidic Ag/AgCl reference electrode and its application for portable and disposable electrochemical microchipsElectrophoresis, 2010
- Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In VitroPharmaceutical Research, 2009
- From newborn to adult: Phenotypic and functional properties of skin equivalent and human skin as a function of donor ageJournal of Cellular Physiology, 1997
- Effect of metabolic alkalosis and metabolic acidosis on urinary kallikrein excretion of anaesthetized rats: evidence for a role of blood pH as regulator of renal kallikrein secretionPflügers Archiv - European Journal of Physiology, 1996
- The Dublin randomized controlled trial of intrapartum fetal heart rate monitoringAmerican Journal of Obstetrics and Gynecology, 1985
- An assessment of continuous fetal heart rate monitoring in laborAmerican Journal of Obstetrics and Gynecology, 1978