Sofia Rodrigues Teixeira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sofia Rodrigues Teixeira has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Robert Steven Conlan
Institute of Life Science, Swansea University Medical School, Faculty of Medicine, Health & Life Science, Swansea University, Swansea, SA2 8PP, United Kingdom, UK
7 shared publications - Paul Galvin
Tyndall National Institute, University College Cork, Cork, Ireland
4 shared publications - Ernest Anthony Azzopardi
Laserplast Stl Stp, Milan, Italy
3 shared publications - Iain Stuart Whitaker
Reconstructive Surgery and Regenerative Medicine Research Centre, Swansea University, Swansea SA2 8PP, UK
3 shared publications - Maria Goreti Ferreira Sales
BioMark, CEMMPRE, ARISE, Department of Chemical Engineering, Faculty of Sciences and Technology, University of Coimbra, Coimbra, Portugal
3 shared publications R. Steven Conlan
Swansea University Medical School, Swansea University, Singleton Park, Swansea, SA2 8PP, UK; Centre for NanoHealth, Swansea University, Singleton Park, Swansea, SA2 8PP, UK
3 shared publications
Latest Publications
- Open Access
- 23 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (17) , 25139-25148
Laser-Induced Graphene-Based Potentiometric pH and Nonenzymatic Uric Acid Sensors for Urine Analysis on Baby Diaper
The fabrication of wearable sensors and their integration into real devices is an emerging demand in the field of sensor development. In this work, flexible sensors based on laser-induced graphene (LIG) were developed using a low-cost visible laser on polyimide tape for pH and uric acid monitoring in urine. A potentiometric pH sensor was fabricated by modifying the LIG surface with polyaniline, achieving a sensitivity of 56.7 ± 2.6 mV/pH across a wide pH range (4–10) with a rapid response time of –1, with a limit of detection (LOD) of 35 μM (3S/N) in the concentration range of 0.05–0.6 mM in buffer solution. Both sensors maintained almost similar sensitivities in artificial urine samples, and their performance was successfully demonstrated in baby diapers using a portable potentiostat, highlighting their potential for miniaturized wearable health monitoring applications.
- 23 April 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (17) , 25139-25148
Open AccessLaser-Induced Graphene-Based Potentiometric pH and Nonenzymatic Uric Acid Sensors for Urine Analysis on Baby Diaper
The fabrication of wearable sensors and their integration into real devices is an emerging demand in the field of sensor development. In this work, flexible sensors based on laser-induced graphene (LIG) were developed using a low-cost visible laser on polyimide tape for pH and uric acid monitoring in urine. A potentiometric pH sensor was fabricated by modifying the LIG surface with polyaniline, achieving a sensitivity of 56.7 ± 2.6 mV/pH across a wide pH range (4–10) with a rapid response time of –1, with a limit of detection (LOD) of 35 μM (3S/N) in the concentration range of 0.05–0.6 mM in buffer solution. Both sensors maintained almost similar sensitivities in artificial urine samples, and their performance was successfully demonstrated in baby diapers using a portable potentiostat, highlighting their potential for miniaturized wearable health monitoring applications.
- Open Access
Biological Validation of Cortisol in Zebrafish Trunk, Skin Mucus, and Water as a Biomarker of Acute or Chronic Stress
The most used technique to assess cortisol in zebrafish is trunk sampling, a terminal procedure. Extracting cortisol non-terminally in adult zebrafish remains challenging, limiting longitudinal studies, and the reduction of the number of zebrafish used in research. This study explored non-terminal methods for cortisol measurement in adult zebrafish under acute and chronic stress, focusing on housing water and skin mucus as alternatives to terminal trunk sampling. Oxidative stress markers (cerebral and hepatic) were also assessed to confirm stress responses. In experiment A, zebrafish were exposed to no stress, acute stress (AS), or chronic stress for 14 days (CS14) to evaluate skin mucus and trunk cortisol as biomarkers. In experiment B, in addition to CS14, a 7-day unpredictable chronic stress protocol (CS7) was tested to discard stress habituation. Results showed significant effects on cerebral oxidative stress: AS increased ROS and AChE activity, CS7 reduced GPx and AChE, and CS14 raised GPx in experiment A, while it increased protein carbonyls and decreased ATPase levels in experiment B. Trunk and skin mucus cortisol increased following AS. Under chronic stress, trunk and skin mucus cortisol levels were not significantly altered, but water cortisol increased at CS7. In conclusion, skin mucus and trunk cortisol levels are reliable biomarkers for acute stress, while water cortisol holds promise for chronic stress.
Open AccessBiological Validation of Cortisol in Zebrafish Trunk, Skin Mucus, and Water as a Biomarker of Acute or Chronic Stress
The most used technique to assess cortisol in zebrafish is trunk sampling, a terminal procedure. Extracting cortisol non-terminally in adult zebrafish remains challenging, limiting longitudinal studies, and the reduction of the number of zebrafish used in research. This study explored non-terminal methods for cortisol measurement in adult zebrafish under acute and chronic stress, focusing on housing water and skin mucus as alternatives to terminal trunk sampling. Oxidative stress markers (cerebral and hepatic) were also assessed to confirm stress responses. In experiment A, zebrafish were exposed to no stress, acute stress (AS), or chronic stress for 14 days (CS14) to evaluate skin mucus and trunk cortisol as biomarkers. In experiment B, in addition to CS14, a 7-day unpredictable chronic stress protocol (CS7) was tested to discard stress habituation. Results showed significant effects on cerebral oxidative stress: AS increased ROS and AChE activity, CS7 reduced GPx and AChE, and CS14 raised GPx in experiment A, while it increased protein carbonyls and decreased ATPase levels in experiment B. Trunk and skin mucus cortisol increased following AS. Under chronic stress, trunk and skin mucus cortisol levels were not significantly altered, but water cortisol increased at CS7. In conclusion, skin mucus and trunk cortisol levels are reliable biomarkers for acute stress, while water cortisol holds promise for chronic stress.
- Open Access
- 8 August 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (8) , 517
Development and Characterisation of a Microneedle Sensor for Intrapartum Fetal Monitoring
This study presents the in vitro and preliminary ex vivo development of a novel microneedle-based pH sensor for continuous intrapartum fetal monitoring. The objective was to evaluate the feasibility of using microneedle sensors to monitor fetal pH during labour and to develop a proof-of-principle microneedle pH sensor that meets clinical requirements such as high sensitivity to small pH changes (0.05 units) within a relevant range (6.50–7.45), minimal tissue disruption, and a compact design suitable for transcervical placement on the fetal scalp (2 = 0.946, accuracy = 97.65%) and −63.2 mV/pH (R2 = 0.910, accuracy = 93.70%) in the external and internal configurations, respectively. In ISF, a slope of −25.5 mV/pH (R2 = 0.979) was obtained. Ex vivo testing on human skin confirmed successful microneedle penetration without visible iridium oxide transfer or tissue damage, as indicated by methylene blue staining. These findings support the potential for continuous minimally invasive fetal pH monitoring during labour, representing a significant step toward more objective and specific intrapartum assessment.
- 8 August 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (8) , 517
Open AccessDevelopment and Characterisation of a Microneedle Sensor for Intrapartum Fetal Monitoring
This study presents the in vitro and preliminary ex vivo development of a novel microneedle-based pH sensor for continuous intrapartum fetal monitoring. The objective was to evaluate the feasibility of using microneedle sensors to monitor fetal pH during labour and to develop a proof-of-principle microneedle pH sensor that meets clinical requirements such as high sensitivity to small pH changes (0.05 units) within a relevant range (6.50–7.45), minimal tissue disruption, and a compact design suitable for transcervical placement on the fetal scalp (2 = 0.946, accuracy = 97.65%) and −63.2 mV/pH (R2 = 0.910, accuracy = 93.70%) in the external and internal configurations, respectively. In ISF, a slope of −25.5 mV/pH (R2 = 0.979) was obtained. Ex vivo testing on human skin confirmed successful microneedle penetration without visible iridium oxide transfer or tissue damage, as indicated by methylene blue staining. These findings support the potential for continuous minimally invasive fetal pH monitoring during labour, representing a significant step toward more objective and specific intrapartum assessment.
- Open Access
- 5 August 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (32) , 36203-36215
A Microneedle-Based Electrochemical Sensor with Multiplex Detection in Physiological Environment and Incorporated in a Portable Device
The number of disorders linked to deficiencies in vital ions, such as calcium (Ca2+) and potassium (K+), has dramatically increased in recent years. Numerous research studies have proposed the development of a sensor for early detection; however, the bulk of these investigations include the time-consuming process of drawing blood samples for testing. To overcome these challenges, this research highlights the development of a novel portable microneedle-based device for the multiplexed detection of Ca2+ and K+, as well as pH, in artificial interstitial fluid (ISF). A passivation layer of ArCare was investigated to improve the stability, reliability, and repeatability of the microneedle sensors, enhancing their sensitivity and accuracy. Microneedle sensors were modified with Poly-(3,4-ethylenedioxythiophene) (PEDOT) and an ion-selective membrane (ISM) to reduce interference caused by other ions when tested in complex media. Successful modification of the surface with PEDOT and ISM was confirmed using electrochemical characterization, Raman Spectroscopy, and Scanning Electron Microscopy (SEM) analysis. The results demonstrated a linear response in the detection of both Ca2+and K+ ions with respect to concentration, with a high coefficient of determination (r 2 >0.9) indicating strong reliability. Additionally, tests were carried out to study the effect of pH on the detection of Ca2+ and K+, revealing a linear detection for both ions across varying pH levels. The multiparametric detection of pH and Ca2+ or K+ was carried out using an in-house built smart sensing platform known as Portable Unit Lab-on-Site Electrochemistry (PULSE). Overall, this work highlights the potential of multi-ion microneedle sensors in portable real-time health monitoring applications.
- 5 August 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (32) , 36203-36215
Open AccessA Microneedle-Based Electrochemical Sensor with Multiplex Detection in Physiological Environment and Incorporated in a Portable Device
The number of disorders linked to deficiencies in vital ions, such as calcium (Ca2+) and potassium (K+), has dramatically increased in recent years. Numerous research studies have proposed the development of a sensor for early detection; however, the bulk of these investigations include the time-consuming process of drawing blood samples for testing. To overcome these challenges, this research highlights the development of a novel portable microneedle-based device for the multiplexed detection of Ca2+ and K+, as well as pH, in artificial interstitial fluid (ISF). A passivation layer of ArCare was investigated to improve the stability, reliability, and repeatability of the microneedle sensors, enhancing their sensitivity and accuracy. Microneedle sensors were modified with Poly-(3,4-ethylenedioxythiophene) (PEDOT) and an ion-selective membrane (ISM) to reduce interference caused by other ions when tested in complex media. Successful modification of the surface with PEDOT and ISM was confirmed using electrochemical characterization, Raman Spectroscopy, and Scanning Electron Microscopy (SEM) analysis. The results demonstrated a linear response in the detection of both Ca2+and K+ ions with respect to concentration, with a high coefficient of determination (r 2 >0.9) indicating strong reliability. Additionally, tests were carried out to study the effect of pH on the detection of Ca2+ and K+, revealing a linear detection for both ions across varying pH levels. The multiparametric detection of pH and Ca2+ or K+ was carried out using an in-house built smart sensing platform known as Portable Unit Lab-on-Site Electrochemistry (PULSE). Overall, this work highlights the potential of multi-ion microneedle sensors in portable real-time health monitoring applications.
- Open Access
- 10 May 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (5) , 304
Multi-Parametric Electrochemical Sensing Platform: Applications in Animal Welfare
The rapid growth of the dairy sector requires advanced monitoring tools to ensure sustainable practices that benefit the environment, economy, and human health. Current monitoring devices often lack multi-parametric capabilities, limiting their ability to provide comprehensive data on critical chemical and biochemical parameters. To address this challenge, this work presented the integration of a real-time multi-parametric device with sensors for pH, temperature, nitrate, and nitrite, providing a comprehensive solution to dairy cattle health monitoring. This solution included an electrochemical platform, Portable Unit for Lab-on-Site Electrochemistry (PULSE), and an application for data processing and display. In-house fabricated flexible gold-printed electrodes demonstrated accurate detection of nitrite and nitrate when integrated with the PULSE, achieving sensitivities of 6.32 A/ppm/ in artificial interstitial fluid and 1.92 A/ppm/ in phosphate buffered saline, respectively. The PULSE achieved 65.83% and 58.3% lower limits of detection in phosphate buffered saline than a benchtop potentiostat, for nitrate and nitrite, respectively, along with a 24.5% increase in nitrite sensitivity, enhancing its ability to detect lower analyte concentrations. pH sensing was carried out with a commercial screen-printed electrode coated with a layer of iridium oxide. The pH was tested in ruminal complex fluid, obtaining a pH sensitivity of −59.63 mV/pH and an accuracy of 98.9%. These findings highlighted the potential of this technology as an effective tool for dairy cattle health monitoring and its deployment in real-world scenarios.- 10 May 2025
- Published by MDPI AG in Biosensors
- Vol. 15 (5) , 304
Open AccessMulti-Parametric Electrochemical Sensing Platform: Applications in Animal Welfare
The rapid growth of the dairy sector requires advanced monitoring tools to ensure sustainable practices that benefit the environment, economy, and human health. Current monitoring devices often lack multi-parametric capabilities, limiting their ability to provide comprehensive data on critical chemical and biochemical parameters. To address this challenge, this work presented the integration of a real-time multi-parametric device with sensors for pH, temperature, nitrate, and nitrite, providing a comprehensive solution to dairy cattle health monitoring. This solution included an electrochemical platform, Portable Unit for Lab-on-Site Electrochemistry (PULSE), and an application for data processing and display. In-house fabricated flexible gold-printed electrodes demonstrated accurate detection of nitrite and nitrate when integrated with the PULSE, achieving sensitivities of 6.32 A/ppm/ in artificial interstitial fluid and 1.92 A/ppm/ in phosphate buffered saline, respectively. The PULSE achieved 65.83% and 58.3% lower limits of detection in phosphate buffered saline than a benchtop potentiostat, for nitrate and nitrite, respectively, along with a 24.5% increase in nitrite sensitivity, enhancing its ability to detect lower analyte concentrations. pH sensing was carried out with a commercial screen-printed electrode coated with a layer of iridium oxide. The pH was tested in ruminal complex fluid, obtaining a pH sensitivity of −59.63 mV/pH and an accuracy of 98.9%. These findings highlighted the potential of this technology as an effective tool for dairy cattle health monitoring and its deployment in real-world scenarios. - Open Access
PULSE: A Fast Portable Unit for Lab-on-Site Electrochemistry
This study aims to develop and validate a novel fast-detection electrochemical sensing platform to enhance portable electrochemical sensor solutions. The research focuses on optimising analogue front-end circuits, developing data analysis algorithms, and validating the device through experiments to enhance measurement accuracy and detection speed, enabling on-site measurements across diverse applications. This work successfully designed a Portable Unit for Lab-on-Site Electrochemistry (PULSE) system with dimensions of . The device’s implementation was complemented by robust firmware that performed desired electrochemical measurements, including open circuit potentiometry (OCP), chronoamperometry (CA), and cyclic voltammetry (CV). To assess its reliability, the PULSE was benchmarked against a well-established benchtop potentiostat. The results obtained highlight the system’s rapid sensing capabilities, achieving pH detection in 2 s and performing CA in 20 s. The pH calibration curve exhibited Nernstian behaviour with an accuracy of 97.58%. A correlation analysis comparing the calibration curve datasets across all electrochemical techniques from both systems revealed high correlation coefficients (>0.99), confirming the strong agreement between the two systems.Open AccessPULSE: A Fast Portable Unit for Lab-on-Site Electrochemistry
This study aims to develop and validate a novel fast-detection electrochemical sensing platform to enhance portable electrochemical sensor solutions. The research focuses on optimising analogue front-end circuits, developing data analysis algorithms, and validating the device through experiments to enhance measurement accuracy and detection speed, enabling on-site measurements across diverse applications. This work successfully designed a Portable Unit for Lab-on-Site Electrochemistry (PULSE) system with dimensions of . The device’s implementation was complemented by robust firmware that performed desired electrochemical measurements, including open circuit potentiometry (OCP), chronoamperometry (CA), and cyclic voltammetry (CV). To assess its reliability, the PULSE was benchmarked against a well-established benchtop potentiostat. The results obtained highlight the system’s rapid sensing capabilities, achieving pH detection in 2 s and performing CA in 20 s. The pH calibration curve exhibited Nernstian behaviour with an accuracy of 97.58%. A correlation analysis comparing the calibration curve datasets across all electrochemical techniques from both systems revealed high correlation coefficients (>0.99), confirming the strong agreement between the two systems. - Open Access
- 9 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (9) , 327
Immunosensor for Assessing the Welfare of Trainee Guide Dogs
Cortisol is a well established biomarker hormone that regulates many processes in the body and is widely referred to as the stress hormone. Cortisol can be used as a stress marker to allow for detection of stress levels in dogs during the training process. This test will indicate if they will handle the stress under the training or if they might be more suitable as an assistant or companion dog. An immunosensor for detection of cortisol was developed using electrochemical impedance spectroscopy (EIS). The sensor was characterized using chemical and topographical techniques. The sensor was calibrated and its sensitivity determined using a cortisol concentration range of 0.0005 to 50 μg/mL. The theoretical limit of detection was found to be 3.57 fg/mL. When the immunosensor was tested on canine saliva samples, cortisol was detected and measured within the relevant physiological ranges in dogs.
- 9 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (9) , 327
Open AccessImmunosensor for Assessing the Welfare of Trainee Guide Dogs
Cortisol is a well established biomarker hormone that regulates many processes in the body and is widely referred to as the stress hormone. Cortisol can be used as a stress marker to allow for detection of stress levels in dogs during the training process. This test will indicate if they will handle the stress under the training or if they might be more suitable as an assistant or companion dog. An immunosensor for detection of cortisol was developed using electrochemical impedance spectroscopy (EIS). The sensor was characterized using chemical and topographical techniques. The sensor was calibrated and its sensitivity determined using a cortisol concentration range of 0.0005 to 50 μg/mL. The theoretical limit of detection was found to be 3.57 fg/mL. When the immunosensor was tested on canine saliva samples, cortisol was detected and measured within the relevant physiological ranges in dogs.
- 1 June 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 157, 112144
Non-invasive molecular assessment of human embryo development and implantation potential
- 1 June 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 157, 112144
Non-invasive molecular assessment of human embryo development and implantation potential
- Open Access
- 20 May 2020
- Published by Wiley in Molecular Ecology
- Vol. 29 (12) , 2288-2299
Environmental enrichment induces intergenerational behavioural and epigenetic effects on fish
Parental effects influence offspring phenotypes through pre‐ and post‐natal routes but little is known about their molecular basis, and therefore their adaptive significance. Epigenetic modifications, which control gene expression without changes in the DNA sequence and are influenced by the environment, may contribute to parental effects. We investigated the effects of environmental enrichment on the behaviour, metabolic rate and brain DNA methylation patterns of parents and offspring of the highly inbreed mangrove killifish (Kryptolebias marmoratus). Parental fish reared in enriched environments had lower cortisol levels, lower metabolic rates and were more active and neophobic than those reared in barren environments. They also differed in 1,854 methylated cytosines (DMCs). Offspring activity and neophobia were determined by the parental environment. Among the DMCs of the parents, 98 followed the same methylation patterns in the offspring, three of which were significantly influenced by parental environments irrespective of their own rearing environment. Our results suggest that parental environment influences the behaviour and, to some extent, the brain DNA methylation patterns of the offspring.
- 20 May 2020
- Published by Wiley in Molecular Ecology
- Vol. 29 (12) , 2288-2299
Open AccessEnvironmental enrichment induces intergenerational behavioural and epigenetic effects on fish
Parental effects influence offspring phenotypes through pre‐ and post‐natal routes but little is known about their molecular basis, and therefore their adaptive significance. Epigenetic modifications, which control gene expression without changes in the DNA sequence and are influenced by the environment, may contribute to parental effects. We investigated the effects of environmental enrichment on the behaviour, metabolic rate and brain DNA methylation patterns of parents and offspring of the highly inbreed mangrove killifish (Kryptolebias marmoratus). Parental fish reared in enriched environments had lower cortisol levels, lower metabolic rates and were more active and neophobic than those reared in barren environments. They also differed in 1,854 methylated cytosines (DMCs). Offspring activity and neophobia were determined by the parental environment. Among the DMCs of the parents, 98 followed the same methylation patterns in the offspring, three of which were significantly influenced by parental environments irrespective of their own rearing environment. Our results suggest that parental environment influences the behaviour and, to some extent, the brain DNA methylation patterns of the offspring.
- 1 September 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 141, 111386
Direct monitoring of breast and endometrial cancer cell epigenetic response to DNA methyltransferase and histone deacetylase inhibitors
- 1 September 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 141, 111386
Direct monitoring of breast and endometrial cancer cell epigenetic response to DNA methyltransferase and histone deacetylase inhibitors