The Use of a Handheld Ultrasound Device to Guide the Axillary Vein Access during Pacemaker and Cardioverter-Defibrillator Implantation. A Feasibility Study
Authors:
Open Access
- 20 July 2022
- journal article
- research article
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 23 (8) , 258
Abstract
Background: Although ultrasound guidance for axillary vein (AV) access (USGAVA) has been described as a reliable technique for cardiac implantable electronic device (CIED) implantation, no data is available on the use of handheld ultrasound devices (HUD) in such a setting. Objective: We investigated the feasibility of using a HUD for USGAVA in patients referred to our Institution for CIED implantation. Methods: The procedure details of 80 consecutive patients undergoing USGAVA (Group-1) from June 2020 to June 2021 were prospectively collected and compared to those of an age and sex-matched cohort of 91 patients (Group-2) who had undergone AV access with the traditional venipuncture guided by fluoroscopic landmarks. Results: The two groups were comparable for the success rate of venous access (92.5% versus 93.4%, p = 0.82), complication rate (1.3% versus 0.9%, p = 1.0), and procedure time (71 ± 32 min versus 70 ± 29 min, p = 0.9). However, Group-2 had a longer X-ray exposure time (7.6 ± 8.4 min versus 5.7 ± 7.3 min, p = 0.03). In Group-1, the univariate logistic regression analysis demonstrated that the AV diameter was associated with successful USGAVA (odds ratio = 3.34, 95% confidence interval 1.47–7.59, p < 0.01), with a 3-fold increase of probability of success per each 1 mm increase in the AV diameter. Conclusions: USGAVA using a HUD for CIED implantation is a feasible, effective, and safe technique; moreover, it saves X-ray exposure time without lengthening the implant procedure time.Keywords
This publication has 24 references indexed in Scilit:
- Feasibility of ultrasound-guided vascular access during cardiac implantable device placementJournal of Interventional Cardiac Electrophysiology, 2017
- Implantation of cardiac resynchronization therapy devices using three leads by cephalic vein dissection approachEP Europace, 2017
- Venous access and long-term pacemaker lead failure: comparing contrast-guided axillary vein puncture with subclavian puncture and cephalic cutdownEP Europace, 2016
- The Use of Ultrasound to Improve Axillary Vein Access and Minimize Complications during Pacemaker ImplantationPacing and Clinical Electrophysiology, 2016
- Wireless Ultrasound‐Guided Axillary Vein Cannulation for the Implantation of Cardiovascular Implantable Electric DevicesJournal of Cardiovascular Electrophysiology, 2016
- Antithrombotic management in patients undergoing electrophysiological procedures: a European Heart Rhythm Association (EHRA) position document endorsed by the ESC Working Group Thrombosis, Heart Rhythm Society (HRS), and Asia Pacific Heart Rhythm Society (APHRS)EP Europace, 2015
- Preferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association surveyEP Europace, 2013
- Axillary Vein Puncture Without Contrast Venography for Pacemaker and Defibrillator Leads ImplantationPacing and Clinical Electrophysiology, 2013
- Ultrasound‐Guided Venous Access for Pacemakers and DefibrillatorsJournal of Cardiovascular Electrophysiology, 2012
- Pneumothorax in cardiac pacing: a population-based cohort study of 28 860 Danish patientsEP Europace, 2012