Whole blood chromium concentration is very rarely elevated independently of whole blood cobalt
Authors:
Open Access
- 11 June 2021
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-9
Abstract
Due to the risk of adverse reactions to metal debris resulting from increased wear of the arthroplasty more than one million metal-on-metal (MoM) hip replacements worldwide are in active follow-up. Follow-up usually includes measurement of both whole blood cobalt (Co) and chromium (Cr) concentrations. Our experience is that Cr is seldom independently elevated. We wanted to ascertain whether blood Cr measurements could be omitted from follow-up protocols without lowering the quality of follow-up. We identified 8438 whole blood Co and Cr measurements performed without or prior to revision surgery. When the cut-off levels 5 µg/L and 7 µg/L were used, Cr was independently elevated in only 0.5% (95% confidence interval, CI, 0.3 to 0.6) and 0.2% (CI 0.1 to 0.3) of the measurements. The models with continuous variables showed that the higher the blood metal concentrations are the lower the percentage of measurements with Cr higher than Co. Our results suggest that whole blood Cr is very rarely independently elevated and therefore the authorities should consider omitting Cr measurements from their screening guidelines of MoM hip replacements. We believe this change in practice would simplify follow-up and lead to cost savings without decreasing the quality of follow-up.Keywords
This publication has 21 references indexed in Scilit:
- The Cobalt/Chromium Ratio Provides Similar Diagnostic Value to a Low Cobalt Threshold in Predicting Adverse Local Tissue Reactions in Patients With Metal-on-Metal Hip ArthroplastyThe Journal of Arthroplasty, 2018
- The Effectiveness of Blood Metal Ions in Identifying Patients with Unilateral Birmingham Hip Resurfacing and Corail-Pinnacle Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal DebrisJournal of Bone and Joint Surgery, 2016
- The Interchangeability of Plasma and Whole Blood Metal Ion Measurement in the Monitoring of Metal on Metal HipsArthritis, 2015
- Follow-Up of Metal-on-Metal Hip Arthroplasty Patients Is Currently Not Evidence Based or Cost EffectiveThe Journal of Arthroplasty, 2015
- The 2012 Otto Aufranc Award: The Interpretation of Metal Ion Levels in Unilateral and Bilateral Hip ResurfacingClinical Orthopaedics and Related Research, 2013
- Consensus Statement “Current Evidence on the Management of Metal-on-Metal Bearings”: April 16, 2012HIP International, 2013
- The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hipThe Journal of Bone and Joint Surgery. British volume, 2012
- How safe are metal-on-metal hip implants?BMJ, 2012
- Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacementThe Journal of Bone and Joint Surgery. British volume, 2011
- Metal Ion Interpretation in Resurfacing versus Conventional Hip Arthroplasty and in Whole Blood versus Serum. How should we Interpret Metal Ion Data?HIP International, 2011