Validation of a rapid, semiautomatic image analysis tool for measurement of gastric accommodation and emptying by magnetic resonance imaging
- 15 April 2015
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Gastrointestinal and Liver Physiology
- Vol. 308 (8) , G652-G663
Abstract
Magnetic resonance imaging (MRI) has advantages for the assessment of gastrointestinal structures and functions; however, processing MRI data is time consuming and this has limited uptake to a few specialist centers. This study introduces a semiautomatic image processing system for rapid analysis of gastrointestinal MRI. For assessment of simpler regions of interest (ROI) such as the stomach, the system generates virtual images along arbitrary planes that intersect the ROI edges in the original images. This generates seed points that are joined automatically to form contours on each adjacent two-dimensional image and reconstructed in three dimensions (3D). An alternative thresholding approach is available for rapid assessment of complex structures like the small intestine. For assessment of dynamic gastrointestinal function, such as gastric accommodation and emptying, the initial 3D reconstruction is used as reference to process adjacent image stacks automatically. This generates four-dimensional (4D) reconstructions of dynamic volume change over time. Compared with manual processing, this semiautomatic system reduced the user input required to analyze a MRI gastric emptying study (estimated 100 vs. 10,000 mouse clicks). This analysis was not subject to variation in volume measurements seen between three human observers. In conclusion, the image processing platform presented processed large volumes of MRI data, such as that produced by gastric accommodation and emptying studies, with minimal user input. 3D and 4D reconstructions of the stomach and, potentially, other gastrointestinal organs are produced faster and more accurately than manual methods. This system will facilitate the application of MRI in gastrointestinal research and clinical practice.Keywords
This publication has 35 references indexed in Scilit:
- Delayed gastric emptying and reduced postprandial small bowel water content of equicaloric whole meal bread versus rice meals in healthy subjects: novel MRI insightsEuropean Journal of Clinical Nutrition, 2013
- Gastric motor disturbances in patients with idiopathic rapid gastric emptyingNeurogastroenterology & Motility, 2011
- Effect of meal volume and calorie load on postprandial gastric function and emptying: studies under physiological conditions by combined fiber-optic pressure measurement and MRIAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2009
- 96 The Structure and Function of the Gastro-Esophageal Junction in Health and Reflux Disease Assessed By Magnetic Resonance Imaging and High Resolution ManometryGastroenterology, 2009
- Quantitative analysis of peristaltic and segmental motion in vivo in the rat small intestine using dynamic MRIMagnetic Resonance in Medicine, 2009
- Application of magnetic resonance imaging to measure fasting and postprandial volumes in humansNeurogastroenterology & Motility, 2008
- 1054 Paroxetin, a Selective 5-Hydroxytryptamine RE-Uptake Inhibitor, Increases Postprandial Gastric Volumes and Decreases Symptoms in Patients with Postprandial Distress Syndrome (PDS) Functional Dyspepsia (FD)Gastroenterology, 2008
- Real time high resolution magnetic resonance imaging for the assessment of gastric motility disordersGut, 2004
- Real‐time high‐resolution MRI for the assessment of gastric motility: Pre‐ and postpharmacological stimuliJournal of Magnetic Resonance Imaging, 2004
- Survey over image thresholding techniques and quantitative performance evaluationJournal of Electronic Imaging, 2004