SBSreerup Banerjee

Sreerup Banerjee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sreerup Banerjee has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Portable sterilizer with microbe content detection device

    by Sreerup Banerjee, Shriram Raghunathan, Saubhik Banerjee, Boudhayan Bandyopadhyay

    Background: Infectious diseases, such as the latest COVID pandemic, caused by microorganisms like bacteria and virus, wreak havoc shaking human civilization with its rapid infection rate, and high number of mortalities. In case of a contagious disease, the virus can survive on any surface over a period of time and can be transferred to the human host through touching those surfaces unknowingly. Cleaning those possible surfaces to which these microorganisms can cling onto is one of the major ways to curb the spread. The aim of this study was to design a sterilizer which can clean such surfaces of daily used items easily within a certain period of time and can assess the cleaning efficacy by estimating the presence of microbes before and after sanitization. Method development: To achieve this goal, we propose a portable sterilization unit that contains a sterilization chamber fitted with a microbe content detector. The sterilization chamber will cleanse the surfaces off the microbes using ultraviolet radiation. The chamber can be portable and at the same time big enough to accommodate items of daily use, like watch, wallet, clothes, utensils to even foods for single-house application. The microbe content detector will detect the success of the sterilization procedure by examining the time-lapse laser speckle images captured by a high-speed camera by mean of image processing algorithm, such that the user can determine whether further sterilization is required. Conclusions: Microbe content detection device associated with the conventional sterilization procedure will give an assessment of the effectiveness of the sterilization. Successful implementation of sterilization for a wide variety of items of everyday use aided with microbe content detection technique is first of its kind and should be an effective tool for use in large communities, offices and public places for effective sterilization to help fight against the spread of infectious diseases.


  • Cover Image

    by Sreerup Banerjee, Anupam Pal, Mark Fox

  • Volume and position change of the stomach during gastric accommodation and emptying: A detailed three‐dimensional morphological analysis based on MRI

    by Sreerup Banerjee, Anupam Pal, Mark Fox

    Background: The proximal and distal regions of the stomach are thought to have different roles during gastric accommodation and emptying; however, regional changes in gastric structure and function during and after a meal have not been described in detail. This study applied non‐invasive imaging to study changes in regional gastric volume and morphology during accommodation and emptying of a liquid nutrient meal.Method: MRI studies were performed on 16 healthy volunteers. Three‐dimensional (3D) gastric morphology was reconstructed by validated image processing technology. The 3D models were segmented into seven regions. The relative contribution of each region to gastric accommodation and emptying was assessed. Changes in morphology were documented by tracking movements of four distinct gastric landmarks.Key Results: The initial 100 mL liquid nutrient increases distal stomach volume more than that of other gastric regions (∆V7 = 28 ± 6% ∆TGV; P ≤ .05). Subsequent volume is accommodated mainly in the proximal stomach (∆V1 = 42 ± 10% ∆TGV; P ≤ .05). Early‐phase emptying occurs from distal stomach with proximal stomach volume remaining stable. Subsequently, distal stomach volume remains stable while proximal stomach volume decreases progressively. During gastric filling, the stomach elongates and expands anteriorly and inferiorly (15.2 ± 7.4 mm and 32.3 ± 8.4 mm, respectively, for the incisural midpoint) with torsion indicated by ~70° difference in the movements of proximal and distal gastric landmarks.Conclusions and Inferences: Non‐invasive MRI describes volume change and distribution of a liquid meal within proximal and distal stomach during gastric accommodation and emptying. Additionally, novel observations of changes to 3D gastric morphology within the abdomen are documented.


  • BIOMECHANICAL PERFORMANCE OF A MODIFIED DESIGN OF DYNAMIC CERVICAL IMPLANT COMPARED TO CONVENTIONAL BALL AND SOCKET DESIGN OF AN ARTIFICIAL INTERVERTEBRAL DISC IMPLANT: A FINITE ELEMENT STUDY

    by Shambo Bhattacharya, Sandipan Roy, Masud Rana, Sreerup Banerjee, Santanu Kumar Karmakar, Jayanta Kumar Biswas

    Most of the implants used for total disc replacement (TDR) surgery are designed as a ball and socket pair aimed at providing a three-dimensional unconstrained motion. However, one of the major concerns with ball and socket design is the wear of the implant which limits its life. In this study the biomechanical performance of two types of implant designs is compared — a conventional ball and socket type (Prodisc-C) and a modified design of dynamic cervical implant (DCI) using FE analysis. A 3-dimensional geometrical model of cervical spine (C1–T1) was developed using CT scan data of a middle-aged healthy male. Subsequently, using FE analysis, the ROM values were validated with the existing literature using a compressive load in combination with different physiological motions of the neck. Furthermore, FE analysis on the two implants, fitted at C5–C6 segment, showed a significant increase in the ROM of implanted segment using Prodisc and decrease in the ROM of inferior segment, but modified-DCI restored the motion of the implanted and adjacent segments. Analysis of average bone strains adjacent to the implant showed a possibility of stress shielding for Prodisc. However, higher stress distribution on the modified-DCI limited its clinical use.


  • Validation of a rapid, semiautomatic image analysis tool for measurement of gastric accommodation and emptying by magnetic resonance imaging

    by Sreerup Banerjee, Sudeepa Dixit, Mark Fox, Anupam Pal

    Magnetic resonance imaging (MRI) has advantages for the assessment of gastrointestinal structures and functions; however, processing MRI data is time consuming and this has limited uptake to a few specialist centers. This study introduces a semiautomatic image processing system for rapid analysis of gastrointestinal MRI. For assessment of simpler regions of interest (ROI) such as the stomach, the system generates virtual images along arbitrary planes that intersect the ROI edges in the original images. This generates seed points that are joined automatically to form contours on each adjacent two-dimensional image and reconstructed in three dimensions (3D). An alternative thresholding approach is available for rapid assessment of complex structures like the small intestine. For assessment of dynamic gastrointestinal function, such as gastric accommodation and emptying, the initial 3D reconstruction is used as reference to process adjacent image stacks automatically. This generates four-dimensional (4D) reconstructions of dynamic volume change over time. Compared with manual processing, this semiautomatic system reduced the user input required to analyze a MRI gastric emptying study (estimated 100 vs. 10,000 mouse clicks). This analysis was not subject to variation in volume measurements seen between three human observers. In conclusion, the image processing platform presented processed large volumes of MRI data, such as that produced by gastric accommodation and emptying studies, with minimal user input. 3D and 4D reconstructions of the stomach and, potentially, other gastrointestinal organs are produced faster and more accurately than manual methods. This system will facilitate the application of MRI in gastrointestinal research and clinical practice.


  • Open Access

    Effects of baclofen on the functional anatomy of the oesophago-gastric junction and proximal stomach in healthy volunteers and patients with GERD assessed by magnetic resonance imaging and high-resolution manometry: a randomised controlled double-blind st

    by J. Curcic, A. Schwizer, E. Kaufman, Z. Forras-Kaufman, S. Banerjee, A. Pal, G. S. Hebbard, P. Boesiger, M. Fried, A. Steingoetter, et al.

    Background The mechanism of reflux protection may involve a ‘flap valve’ at the oesophago‐gastric junction (OGJ). Aim To assess the effects of baclofen, a gamma‐aminobutyric acid receptor type‐B (GABA‐B) agonist known to suppress reflux events, on the ‘functional anatomy’ of the OGJ and proximal stomach after a large test meal. Methods Twelve healthy volunteers (HVs) and 12 patients with gastro‐oesophageal reflux disease (GERD); with erosive oesophagitis or pathological oesophageal acid exposure completed a randomised, double‐blind, cross‐over study. On 2 test days participants received 40‐mg baclofen or placebo before ingestion of a large test meal. OGJ structure and function were assessed by high‐resolution manometry (HRM) and magnetic resonance imaging (MRI) using validated methods. Measurements of the oesophago‐gastric angle were derived from three‐dimensional models reconstructed from anatomic MRI images. Cine‐MRI and HRM identified postprandial reflux events. Mixed model analysis and Wilcoxon rank signed tests assessed differences between participant groups and treatment conditions. Results In both HVs and GERD patients, baclofen reduced the frequency of postprandial reflux events. The oesophago‐gastric insertion angle in GERD patients was reduced (−4.1 ± 1.8, P = 0.025), but was unchanged in healthy controls. In both study groups, baclofen augmented lower oesophageal sphincter (LES) pressure (HVs: +7.3 ± 1.8 mmHg, P < 0.0001, GERD: +4.50 ± 1.49 mmHg, P < 0.003) and increased LES length (HVs: +0.48 ± 0.11 cm, P < 0.0003, GERD: +0.35 ± 0.06 cm, P < 0.0001). Conclusions Baclofen inhibits transient LES relaxations and augments LES pressure and length. Additionally, baclofen has effects on the ‘functional anatomy’ of the OGJ and proximal stomach in GERD patients, which may suppress reflux by means of a ‘flap valve’ mechanism.


  • 418 Effect of Baclofen on the Mechanism of Reflux Protection in Healthy Volunteers and Patients With Gastro-Esophageal Reflux Disease (GERD) Assessed by Magnetic Resonance Imaging (MRI) and High Resolution Manometry (HRM): A Randomized Controlled Study

    by Jelena Curcic, Alexandra Schwizer, Elad Kaufman, Sreerup Banerjee, Anupam Pal, Zsofia Forras-Kaufman, Michael Fried, Werner Schwizer, Peter Boesiger, Andreas Steingoetter, et al.