Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience
Open Access
- 22 September 2015
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 10 (1) , 1-8
Abstract
The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18–54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.Keywords
Funding Information
- Zhejiang Provincial Natural Science Foundation of China (LQ12H06002)
- Zhejiang Provincial Natural Science Foundation of China (LQ12H06002)
- Zhejiang Provincial Natural Science Foundation of China (LQ12H06002)
- Zhejiang provincial health department funding (2013KYB176)
- Zhejiang provincial health department funding (2013KYB176)
- Zhejiang provincial health department funding (2012R413006)
This publication has 43 references indexed in Scilit:
- Open reduction and internal fixation of a traumatic diastasis of the pubic symphysisThe Journal of Bone and Joint Surgery. British volume, 2011
- Morphometric Comparisons Between the Pedicle and the Pedicle Rib Unit in the Immature Chinese Thoracic SpineSpine, 2010
- Mortality in Patients With Pelvic Fractures: Results From the German Pelvic Injury RegisterJournal of Trauma: Injury, Infection & Critical Care, 2008
- Incidence and Economic Burden of Osteoporosis-Related Fractures in the United States, 2005–2025Journal of Bone and Mineral Research, 2007
- Successful laparoscopic repair of a traumatic pubic symphysis herniaSurgical Endoscopy, 2003
- Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic BoneJournal of Biomechanical Engineering, 1995
- Box Plate Fixation of the Symphysis Pubis: Biomechanical Evaluation of a New TechniqueJournal of Orthopaedic Trauma, 1994
- Mechanical and textural properties of pelvic trabecular boneJournal of Biomechanics, 1993
- Results in Patients with Craniocerebral Trauma and an Operatively Managed Acetabular FractureJournal of Orthopaedic Trauma, 1990
- Pelvic Ring Disruptions with Symphysis Pubis DiastasisClinical Orthopaedics and Related Research, 1985