    Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience

    by Ke-He Yu, Jian-Jun Hong, Xiao-Shan Guo, Dong-Sheng Zhou

    The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18–54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.


  • Anatomical Measurement and Finite Element Study on Screw Channel Parameter in Percutaneous Fixation of Canulated Screw for Symphyseolysis

    by Kehe Yu, Jianjun Hong, Yuefei Sun, Chengdi Shi, Xiaoshan Guo, Dongsheng Zhou

    To provide anatomical basement for symphyseolysis treatment with percutaneous fixation of canulated screw, through anatomical measurement on pubic symphysis and the surrounding tissues, and conduct the finite element studies on screw channel parameters. 20 cases of normal pelvic specimens from embalmed adult cadavers were taken to measure the anatomical parameter of bony remark of pubic symphysis and the space between spermatic cord (round ligament of the uterus) and pubic tubercle. Anatomical measurement results showed that the narrowest diameter of the superior ramus of pubis was 9.127 ± 1.189 mm, distance between two pubic tubercles was 55.656 ± 3.780 mm, thickness of the upper pubic symphysis was 10.510 ± 0.814 mm, and distance between upper and lower pubic symphysis was 40.872 ± 1.211 mm; the distance between round ligament of the uterus and pubic tubercle was 4.408 ± 0.304 mm, and the distance between spermatic cord and pubic tubercle was 5.196 ± 0.251 mm. The angle between canulated screw guide pin and horizontal plane was 8.342 ± 2.152°, the one between guide pin and coronal plane was 5.236 ± 1.612°, and the distance from entry point to the outer edge of pubic tubercle was 10.023 ± 1.245 mm, which was measured by Mimics software. Percutaneous surgery at horizontal position was simulated on cadaver. And the screw was correctly placed in postoperative imaging examination. According to the anatomical data and finite element studies of screw channel parameter in percutaneous fixation of canulated screw for symphyseolysis, the method can improve the accuracy of screw placement and reduce complications.