Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison
- 24 July 2014
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 24 (11) , 2677-2684
Abstract
To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). We retrospectively analysed paired studies in 72 patients (41 male, 60.5 ± 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 ± 5.9, 15.7 ± 6.1, P = 0.009), CNR (11.6 ± 5.3, 13.2 ± 5.6, P = 0.011), and FOM (19.9 ± 23.3, 43.8 ± 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 ± 8.4 HU, 22.7 ± 7.1 HU, P = 0.048) and mean effective dose (10.6 ± 5.9 mSv, 8.8 ± 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. • Automatic tube voltage selection optimizes tube voltage for each individual patient. • In this population, overall radiation dose decreased while image quality improved. • This tool may become valuable for improving dose/quality ratio.Keywords
This publication has 30 references indexed in Scilit:
- Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: Effects on radiation exposure and image qualityEuropean Journal of Radiology, 2013
- Clinical evaluation of automatic tube voltage selection in chest CT angiographyEuropean Radiology, 2013
- Cardiac Computed Tomography Angiography With Automatic Tube Potential SelectionJournal of Thoracic Imaging, 2013
- Cardiovascular CT angiography in neonates and children: Image quality and potential for radiation dose reduction with iterative image reconstruction techniquesEuropean Radiology, 2012
- Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and ApproachesRadiology, 2010
- High-Pitch Dual-Source CT Angiography of the Thoracic and Abdominal Aorta: Is Simultaneous Coronary Artery Assessment Possible?American Journal of Roentgenology, 2010
- Optimization of Tube Current in Coronary Multidetector Computed Tomography AngiographyJournal of Computer Assisted Tomography, 2009
- Low-dose CT Coronary Angiography Using Prospective ECG-TriggeringAcademic Radiology, 2009
- Radiation dose of cardiac dual-source CT: The effect of tailoring the protocol to patient-specific parametersEuropean Journal of Radiology, 2008
- Pediatric Cardiovascular CT Angiography: Radiation Dose Reduction Using Automatic Anatomic Tube Current ModulationAmerican Journal of Roentgenology, 2008