A microchip integrating cell array positioning with in situ single-cell impedance measurement
- 3 August 2015
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (19) , 6571-6578
Abstract
This paper presents a novel microarray chip integrating cell positioning with in situ, real-time and long-time impedance measurement on a single cell. The microchip integrates a plurality of quadrupole-electrode units (termed positioning electrodes) patterned into an array with pairs of planar electrodes (termed measuring electrodes) located at the centers of each quadrupole-electrode unit. The positioning electrodes are utilized to trap and position living cells onto the measuring electrodes based on negative dielectrophoresis (nDEP), while the measuring electrodes are used to measure impedances of the trapped single cells. Each measuring electrode has a small footprint area of 7 × 7 μm2 to ensure inhabiting only one single cell on it. However, the electrode with a small surface area has a low double-layer capacitance when it is immersed in a liquid solution, thus generating a large double-layer impedance, which reduces the sensitivity for impedance measurement on the single cell. To enlarge the effective surface areas of the measuring electrodes, a novel surface-modification process is proposed to controllably construct gold nanostructures on the surfaces of the measuring electrodes while the positioning electrodes are unstained. The double layer capacitances of the modified electrodes are increased by about one order after surface-modification. The developed microchip is used to monitor the adhering behavior of a single HeLa cell by measuring its impedance spectra in real time. The measured impedance is analyzed and used to extract cellular electrical parameters, which demonstrated that the cell compresses the electrical double layer in the process of adherence and adheres onto the measuring electrodes after 4–5 hours.Keywords
Funding Information
- National Natural Science Foundation of China (No. 91123017)
This publication has 30 references indexed in Scilit:
- Impedimetric cell-based biosensor for real-time monitoring of cytopathic effects induced by dengue virusesBiosensors and Bioelectronics, 2015
- Biotoxin Detection Using Cell-Based SensorsToxins, 2013
- Electrical characteristics analysis of various cancer cells using a microfluidic device based on single-cell impedance measurementSensors and Actuators B: Chemical, 2012
- Real-time characterization of cytotoxicity using single-cell impedance monitoringThe Analyst, 2012
- Real-time, label-free monitoring of the cell cycle with a cellular impedance sensing chipBiosensors and Bioelectronics, 2010
- Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometryLab on a Chip, 2009
- Impedance-Based Monitoring of Ongoing Cardiomyocyte Death Induced by Tumor Necrosis Factor-αBiophysical Journal, 2009
- An automatic and quantitative on-chip cell migration assay using self-assembled monolayers combined with real-time cellular impedance sensingLab on a Chip, 2008
- Cellular impedance biosensors for drug screening and toxin detectionThe Analyst, 2007
- Quantification of the Heterogeneity in Breast Cancer Cell Lines Using Whole-Cell Impedance SpectroscopyClinical Cancer Research, 2007