Rong Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rong Zhu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Xianli Zong
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, Beijing, 100084, China
3 shared publications- Xiaoliang Guo
College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
3 shared publications - Ruiyi Que
State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instruments, Tsinghua University, China
2 shared publications - Wenming Yang
School of Mechanical Engineering, University of Science and Technology Beijing, Beijing, China
2 shared publications B.Y. Liu
School of Mechanical Engineering, University of Science and Technology Beijing, Beijing, 100083, China
1 shared publication- Beiying Liu
School of Mechanical Engineering, University of Science and Technology Beijing, Beijing, China
1 shared publication
Latest Publications
- 6 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 46 (9) , 3179-3187
Simulation of Gas Discharge in a Needle-to-Plane Geometry With Hundreds of Micrometers Gap and Its Enlightenment for Direct Charging of Aerosol Particles
It is necessary to recognize the spatial distribution of ion density and temperature in some practical applications. While numerical modeling is a useful method to fulfill this task, a self-consistent numerical model based on the first few moments of the Boltzmann transport equation coupled to Poisson's equation was built using COMSOL Multiphysics to simulate the dc discharge of a needle-to-plane geometry in atmospheric pressure. Simulation of the discharge was carried out for an actual geometry in aerosol sensors when only the main compositions of air and the main collisional populating and depopulating processes were considered. The simulation results demonstrated that the space occupied by the positive ions with a density of sufficiently charging aerosol particles was very limited. In the meanwhile, the electron temperature in the vicinity of the entire plane electrode was higher than the melting point of most metals. Experiments of measuring the current inducted by charged particles with a diameter of 95 nm using devices with narrowed channels showed that the specific current increased to nearly five times when the width of the channel in the charging stage decreases from 5 to 2 mm. Furthermore, the ablation of the plane electrode used in the experiments occurred on almost the entire surface, which was agreed with the prediction by simulation.
- 6 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 46 (9) , 3179-3187
Simulation of Gas Discharge in a Needle-to-Plane Geometry With Hundreds of Micrometers Gap and Its Enlightenment for Direct Charging of Aerosol Particles
It is necessary to recognize the spatial distribution of ion density and temperature in some practical applications. While numerical modeling is a useful method to fulfill this task, a self-consistent numerical model based on the first few moments of the Boltzmann transport equation coupled to Poisson's equation was built using COMSOL Multiphysics to simulate the dc discharge of a needle-to-plane geometry in atmospheric pressure. Simulation of the discharge was carried out for an actual geometry in aerosol sensors when only the main compositions of air and the main collisional populating and depopulating processes were considered. The simulation results demonstrated that the space occupied by the positive ions with a density of sufficiently charging aerosol particles was very limited. In the meanwhile, the electron temperature in the vicinity of the entire plane electrode was higher than the melting point of most metals. Experiments of measuring the current inducted by charged particles with a diameter of 95 nm using devices with narrowed channels showed that the specific current increased to nearly five times when the width of the channel in the charging stage decreases from 5 to 2 mm. Furthermore, the ablation of the plane electrode used in the experiments occurred on almost the entire surface, which was agreed with the prediction by simulation.
- 18 May 2017
- Published by Elsevier in Journal of Electrostatics
- Vol. 87, 236-242
Self-sustaining discharges in needle-to-plane geometry with hundreds of microns electrode gaps
- 18 May 2017
- Published by Elsevier in Journal of Electrostatics
- Vol. 87, 236-242
Self-sustaining discharges in needle-to-plane geometry with hundreds of microns electrode gaps
- Open Access
- 16 February 2016
- Published by Springer Nature in Discover Nano
- Vol. 11 (1) , 1-9
ZnO Nanowire-Based Corona Discharge Devices Operated Under Hundreds of Volts
Minimizing the voltage of corona discharges, especially when using nanomaterials, has been of great interest in the past decade or so. In this paper, we report a new corona discharge device by using ZnO nanowires operated in atmospheric air to realize continuous corona discharge excited by hundreds of volts. ZnO nanowires were synthesized on microelectrodes using electric-field-assisted wet chemical method, and a thin tungsten film was deposited on the microchip to enhance discharging performance. The testing results showed that the corona inception voltages were minimized greatly by using nanowires compared to conventional dischargers as a result of the local field enhancement of nanowires. The corona could be continuously generated and self-sustaining. It was proved that the law of corona inception voltage obeyed the conventional Peek’s breakdown criterion. An optimal thickness of tungsten film coated over ZnO nanowires was figured out to obtain the lowest corona inception voltage. The ion concentration of the nanowire-based discharger attained 1017/m3 orders of magnitude, which is practicable for most discharging applications.
- 16 February 2016
- Published by Springer Nature in Discover Nano
- Vol. 11 (1) , 1-9
Open AccessZnO Nanowire-Based Corona Discharge Devices Operated Under Hundreds of Volts
Minimizing the voltage of corona discharges, especially when using nanomaterials, has been of great interest in the past decade or so. In this paper, we report a new corona discharge device by using ZnO nanowires operated in atmospheric air to realize continuous corona discharge excited by hundreds of volts. ZnO nanowires were synthesized on microelectrodes using electric-field-assisted wet chemical method, and a thin tungsten film was deposited on the microchip to enhance discharging performance. The testing results showed that the corona inception voltages were minimized greatly by using nanowires compared to conventional dischargers as a result of the local field enhancement of nanowires. The corona could be continuously generated and self-sustaining. It was proved that the law of corona inception voltage obeyed the conventional Peek’s breakdown criterion. An optimal thickness of tungsten film coated over ZnO nanowires was figured out to obtain the lowest corona inception voltage. The ion concentration of the nanowire-based discharger attained 1017/m3 orders of magnitude, which is practicable for most discharging applications.
- Open Access
- 12 November 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 16454
Nanostructured gold microelectrodes for SERS and EIS measurements by incorporating ZnO nanorod growth with electroplating
In this paper, a fine gold nanostructure synthesized on selective planar microelectrodes in micro-chip is realized by using an advanced hybrid fabrication approach incorporating growth of nanorods (NRs) with gold electroplating. By this developed nanostructure, integration of in-situ surface-enhanced Raman spectroscopy (SERS) detection with electrochemical impedance spectroscopy (EIS) measurement for label-free, nondestructive, real-time and rapid monitoring on a single cell has been achieved. Moreover, parameters of Au nanostructures such as size of nanoholes/nanogaps can be controllably adjusted in the fabrication. We have demonstrated a SERS enhancement factor of up to ~2.24 × 106 and double-layer impedance decrease ratio of 90% ~ 95% at low frequency range below 200 kHz by using nanostructured microelectrodes. SERS detection and in-situ EIS measurement of a trapped single cell by using planar microelectrodes are realized to demonstrate the compatibility, multi-functions, high-sensitivity and simplicity of the micro-chip system. This dual function platform integrating SERS and EIS is of great significance in biological, biochemical and biomedical applications.
- 12 November 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 16454
Open AccessNanostructured gold microelectrodes for SERS and EIS measurements by incorporating ZnO nanorod growth with electroplating
In this paper, a fine gold nanostructure synthesized on selective planar microelectrodes in micro-chip is realized by using an advanced hybrid fabrication approach incorporating growth of nanorods (NRs) with gold electroplating. By this developed nanostructure, integration of in-situ surface-enhanced Raman spectroscopy (SERS) detection with electrochemical impedance spectroscopy (EIS) measurement for label-free, nondestructive, real-time and rapid monitoring on a single cell has been achieved. Moreover, parameters of Au nanostructures such as size of nanoholes/nanogaps can be controllably adjusted in the fabrication. We have demonstrated a SERS enhancement factor of up to ~2.24 × 106 and double-layer impedance decrease ratio of 90% ~ 95% at low frequency range below 200 kHz by using nanostructured microelectrodes. SERS detection and in-situ EIS measurement of a trapped single cell by using planar microelectrodes are realized to demonstrate the compatibility, multi-functions, high-sensitivity and simplicity of the micro-chip system. This dual function platform integrating SERS and EIS is of great significance in biological, biochemical and biomedical applications.
- 3 August 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (19) , 6571-6578
A microchip integrating cell array positioning with in situ single-cell impedance measurement
This paper presents a novel microarray chip integrating cell positioning with in situ, real-time and long-time impedance measurement on a single cell. The microchip integrates a plurality of quadrupole-electrode units (termed positioning electrodes) patterned into an array with pairs of planar electrodes (termed measuring electrodes) located at the centers of each quadrupole-electrode unit. The positioning electrodes are utilized to trap and position living cells onto the measuring electrodes based on negative dielectrophoresis (nDEP), while the measuring electrodes are used to measure impedances of the trapped single cells. Each measuring electrode has a small footprint area of 7 × 7 μm2 to ensure inhabiting only one single cell on it. However, the electrode with a small surface area has a low double-layer capacitance when it is immersed in a liquid solution, thus generating a large double-layer impedance, which reduces the sensitivity for impedance measurement on the single cell. To enlarge the effective surface areas of the measuring electrodes, a novel surface-modification process is proposed to controllably construct gold nanostructures on the surfaces of the measuring electrodes while the positioning electrodes are unstained. The double layer capacitances of the modified electrodes are increased by about one order after surface-modification. The developed microchip is used to monitor the adhering behavior of a single HeLa cell by measuring its impedance spectra in real time. The measured impedance is analyzed and used to extract cellular electrical parameters, which demonstrated that the cell compresses the electrical double layer in the process of adherence and adheres onto the measuring electrodes after 4–5 hours.
- 3 August 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (19) , 6571-6578
A microchip integrating cell array positioning with in situ single-cell impedance measurement
This paper presents a novel microarray chip integrating cell positioning with in situ, real-time and long-time impedance measurement on a single cell. The microchip integrates a plurality of quadrupole-electrode units (termed positioning electrodes) patterned into an array with pairs of planar electrodes (termed measuring electrodes) located at the centers of each quadrupole-electrode unit. The positioning electrodes are utilized to trap and position living cells onto the measuring electrodes based on negative dielectrophoresis (nDEP), while the measuring electrodes are used to measure impedances of the trapped single cells. Each measuring electrode has a small footprint area of 7 × 7 μm2 to ensure inhabiting only one single cell on it. However, the electrode with a small surface area has a low double-layer capacitance when it is immersed in a liquid solution, thus generating a large double-layer impedance, which reduces the sensitivity for impedance measurement on the single cell. To enlarge the effective surface areas of the measuring electrodes, a novel surface-modification process is proposed to controllably construct gold nanostructures on the surfaces of the measuring electrodes while the positioning electrodes are unstained. The double layer capacitances of the modified electrodes are increased by about one order after surface-modification. The developed microchip is used to monitor the adhering behavior of a single HeLa cell by measuring its impedance spectra in real time. The measured impedance is analyzed and used to extract cellular electrical parameters, which demonstrated that the cell compresses the electrical double layer in the process of adherence and adheres onto the measuring electrodes after 4–5 hours.
- 1 June 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 68, 529-535
Controllably moving individual living cell in an array by modulating signal phase difference based on dielectrophoresis
- 1 June 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 68, 529-535
Controllably moving individual living cell in an array by modulating signal phase difference based on dielectrophoresis
- 22 August 2014
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 6 (21) , 12732-12739
An electric-field assisted growth control methodology for integrating ZnO nanorods with microstructures
The growth control of ZnO nanorods bridging over two microelectrodes in a three-electrode structure (the top cathode and anode, and the bottom gate) was realized using a wet chemical method with the assistance of an electric field generated by applying AC sine wave power on the top electrodes and a DC voltage on the bottom gate. A numerical control model for controlling the growth position, direction and density of ZnO nanorods on the microstructure was established based on the simulation of the electric-field distribution around the microstructures. The three input parameters in the numerical control model were defined as the peak-to-peak voltage of the AC sine wave (x1), the frequency of the AC sine wave (x2) and gate voltage (x3). Moreover, five output parameters (y1, y2, y3, y4, y5) in the model were defined as the electric field intensities at specific points on the electrodes to characterize the growth rate, direction, position and morphology of the ZnO nanorods integrated with the microelectrodes. The relationship between the defined outputs and inputs were established using 3rd polynomial fitting, which served as the numerical control model for the prediction of nanorod growth. The experimental results validated that growth control methodology provides us with an effective approach to integrate ZnO nanorods into devices.
- 22 August 2014
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 6 (21) , 12732-12739
An electric-field assisted growth control methodology for integrating ZnO nanorods with microstructures
The growth control of ZnO nanorods bridging over two microelectrodes in a three-electrode structure (the top cathode and anode, and the bottom gate) was realized using a wet chemical method with the assistance of an electric field generated by applying AC sine wave power on the top electrodes and a DC voltage on the bottom gate. A numerical control model for controlling the growth position, direction and density of ZnO nanorods on the microstructure was established based on the simulation of the electric-field distribution around the microstructures. The three input parameters in the numerical control model were defined as the peak-to-peak voltage of the AC sine wave (x1), the frequency of the AC sine wave (x2) and gate voltage (x3). Moreover, five output parameters (y1, y2, y3, y4, y5) in the model were defined as the electric field intensities at specific points on the electrodes to characterize the growth rate, direction, position and morphology of the ZnO nanorods integrated with the microelectrodes. The relationship between the defined outputs and inputs were established using 3rd polynomial fitting, which served as the numerical control model for the prediction of nanorod growth. The experimental results validated that growth control methodology provides us with an effective approach to integrate ZnO nanorods into devices.
- Open Access
Aircraft Aerodynamic Parameter Detection Using Micro Hot-Film Flow Sensor Array and BP Neural Network Identification
Air speed, angle of sideslip and angle of attack are fundamental aerodynamic parameters for controlling most aircraft. For small aircraft for which conventional detecting devices are too bulky and heavy to be utilized, a novel and practical methodology by which the aerodynamic parameters are inferred using a micro hot-film flow sensor array mounted on the surface of the wing is proposed. A back-propagation neural network is used to model the coupling relationship between readings of the sensor array and aerodynamic parameters. Two different sensor arrangements are tested in wind tunnel experiments and dependence of the system performance on the sensor arrangement is analyzed.
Open AccessAircraft Aerodynamic Parameter Detection Using Micro Hot-Film Flow Sensor Array and BP Neural Network Identification
Air speed, angle of sideslip and angle of attack are fundamental aerodynamic parameters for controlling most aircraft. For small aircraft for which conventional detecting devices are too bulky and heavy to be utilized, a novel and practical methodology by which the aerodynamic parameters are inferred using a micro hot-film flow sensor array mounted on the surface of the wing is proposed. A back-propagation neural network is used to model the coupling relationship between readings of the sensor array and aerodynamic parameters. Two different sensor arrangements are tested in wind tunnel experiments and dependence of the system performance on the sensor arrangement is analyzed.
- 22 January 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (3) , 351-358
Effect of Parasitic Capacitance on Impedance Measurement and Model Extraction
- 22 January 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (3) , 351-358
Effect of Parasitic Capacitance on Impedance Measurement and Model Extraction
- Open Access
A Flexible Flow Sensor System and Its Characteristics for Fluid Mechanics Measurements
In this paper, we present a novel micromachined hot-film flow sensor system realized by a technique using a film depositing processes and incorporating a standard printed circuit. Sensor electrodes and electronic circuits are preprinted on a flexible substrate of polyimide (PI), i.e., a flexible printed circuit board (FPCB). The sensing element, which is made of Cr/Ni/Pt with a temperature coefficient of resistance around 2,000 ppm/K, is fabricated on the FPCB by either magnetron sputtering technology or pulsed laser deposition (PLD). The sensor can be packed efficiently at high-density and integrated with signal processing circuits without additional pads. A simple fabrication process using mature technique and materials selection guarantees that the time and costs are greatly reduced. Both steady-state and transient characteristics of the sensors are experimentally tested, and the results presented to validate the effectiveness of the sensors.
Open AccessA Flexible Flow Sensor System and Its Characteristics for Fluid Mechanics Measurements
In this paper, we present a novel micromachined hot-film flow sensor system realized by a technique using a film depositing processes and incorporating a standard printed circuit. Sensor electrodes and electronic circuits are preprinted on a flexible substrate of polyimide (PI), i.e., a flexible printed circuit board (FPCB). The sensing element, which is made of Cr/Ni/Pt with a temperature coefficient of resistance around 2,000 ppm/K, is fabricated on the FPCB by either magnetron sputtering technology or pulsed laser deposition (PLD). The sensor can be packed efficiently at high-density and integrated with signal processing circuits without additional pads. A simple fabrication process using mature technique and materials selection guarantees that the time and costs are greatly reduced. Both steady-state and transient characteristics of the sensors are experimentally tested, and the results presented to validate the effectiveness of the sensors.