Motion‐resolved four‐dimensional abdominal diffusion‐weighted imaging using PROPELLER EPI (4D‐DW‐PROPELLER‐EPI)
Open Access
- 24 July 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (6) , 2454-2471
Abstract
Purpose To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT).Methods An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting. A new k-space and blade (K-B) amplitude binning method was developed for the proposed 4D-DW-PROPELLER-EPI to optimize the number of blades and the k-space uniformity before performing conventional PROPELLER-EPI reconstruction, by using two metrics to evaluate the adequacy of the acquired data. The proposed 4D-DW-PROPELLER-EPI was preliminarily evaluated in both simulation experiments and in vivo experiments with varying frame rates and different numbers of repeated acquisition.Results The feasibility of achieving distortion-free 4D-DWI images by using the proposed 4D-DW-PROPELLER-EPI technique was demonstrated in both digital phantom and healthy subjects. Evaluation of the 4D completeness metrics shows that the K-B amplitude binning method could simultaneously improve the acquisition efficiency and data reconstruction performance for 4D-DW-PROPELLER-EPI.Conclusion 4D-DW-PROPELLER-EPI with K-B amplitude binning is an advanced technique that can provide distortion-free 4D-DWI images for resolving respiratory motion, and may benefit the application of image-guided abdominal RT.Keywords
This publication has 43 references indexed in Scilit:
- Abdominal applications of diffusion-weighted magnetic resonance imaging: Where do we standWorld Journal of Radiology, 2013
- Two‐dimensional phase cycled reconstruction for inherent correction of echo‐planar imaging nyquist artifactsMagnetic Resonance in Medicine, 2011
- Diffusion imaging in humans at 7T using readout‐segmented EPI and GRAPPAMagnetic Resonance in Medicine, 2010
- Diffusion weighted imaging in the liverWorld Journal of Gastroenterology, 2010
- Diffusion‐weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitionsJournal of Magnetic Resonance Imaging, 2009
- Readout-segmented EPI for rapid high resolution diffusion imaging at 3TEuropean Journal of Radiology, 2008
- Phase and amplitude binning for 4D-CT imagingPhysics in Medicine & Biology, 2007
- Propeller EPI in the other directionMagnetic Resonance in Medicine, 2006
- PROPELLER EPI: An MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortionsMagnetic Resonance in Medicine, 2005
- Single breath‐hold diffusion‐weighted imaging of the abdomenJournal of Magnetic Resonance Imaging, 2003