Lu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lu Wang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chenyang Liu
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, 999077, Hong Kong Special Administrative Region of China
2 shared publications - Hing-Chiu Chang
Department of Biomedical Engineering The Chinese University of Hong Kong Hong Kong China
2 shared publications - Jing Cai
The Hong Kong Polytechnic University
2 shared publications - Tian Li
The Hong Kong Polytechnic University
2 shared publications - Dongrong Yang
Duke University, 20 Duke Medicine Cir, Durham, 27708-0187, UNITED STATES
1 shared publication Haonan Xiao
Department of Radiation Oncology and Physics, Shandong Cancer Hospital and Institute, Huaiyin District, Jinan, 250117, CHINA
1 shared publication
Latest Publications
- Open Access
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Motion-robust magnetic resonance fingerprinting (MR-MRF) for quantitative liver cancer imaging
Objective: This study aims to develop a motion-robust magnetic resonance fingerprinting (MR-MRF) technique for liver cancer imaging to eliminate the need for breath-hold scanning. Approach: To mitigate respiratory motion artifacts in free-breathing abdominal MRF, the MR-MRF technique comprising two core components. First, respiratory motion is modeled by applying an isotropic total variation (TV)-regularized registration algorithm between a target end-of-exhalation (EOE) phase and three motion phases. Second, motion-resolved tissue property maps are reconstructed using a low-rank total variation (LRTV) optimization framework, which incorporates the estimated inter-phase motion to align all acquired MRF dynamics to the EOE phase. MR-MRF is evaluated by 22 patients (mean age, 62 years ± 10 [SD]; 15 males and 7 females) with hepatocellular carcinoma. Radiologist’s blinded assessment and organ boundary sharpness measurements are performed to evaluate the image quality of MR-MRF-derived tissue maps. The test-retest tissue quantification repeatability is assessed by two consecutive MRF scans with distinct breathing patterns. Paired Student’s t-test is used for statistical significance analysis with a p-value threshold of 0.05. Main results: MR-MRF achieved successful reconstruction of motion-resolved tissue maps at EOE phase, with blinded radiologist assessment yielding an average score of 3 (moderate quality - sufficient for diagnosis) for overall image impression. The FWHM of organ boundaries in MR-MRF-derived tissue maps is 3.1mm ± 1.7mm, significantly lower than motion-blurred tissue maps (9.9mm ± 3.4mm, p-value<0.0001). Test-retest analysis demonstrated good repeatability: liver coefficient of variation was 5.5% ± 7.1% (T1), 8.2% ± 4.4% (T2), and 5.0% ± 2.0% (PD), with excellent linear agreement (R² = 0.96, 0.80, and 0.85 for T1, T2, and PD, respectively). Significance: This study establishes the technical foundation of MR-MRF to achieve repeatable and quantitative liver T1/T2/PD mapping under free-breathing conditions at 3T. The results validate the feasibility of addressing respiratory motion in abdominal multi-parametric quantitative MRI.
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Open AccessMotion-robust magnetic resonance fingerprinting (MR-MRF) for quantitative liver cancer imaging
Objective: This study aims to develop a motion-robust magnetic resonance fingerprinting (MR-MRF) technique for liver cancer imaging to eliminate the need for breath-hold scanning. Approach: To mitigate respiratory motion artifacts in free-breathing abdominal MRF, the MR-MRF technique comprising two core components. First, respiratory motion is modeled by applying an isotropic total variation (TV)-regularized registration algorithm between a target end-of-exhalation (EOE) phase and three motion phases. Second, motion-resolved tissue property maps are reconstructed using a low-rank total variation (LRTV) optimization framework, which incorporates the estimated inter-phase motion to align all acquired MRF dynamics to the EOE phase. MR-MRF is evaluated by 22 patients (mean age, 62 years ± 10 [SD]; 15 males and 7 females) with hepatocellular carcinoma. Radiologist’s blinded assessment and organ boundary sharpness measurements are performed to evaluate the image quality of MR-MRF-derived tissue maps. The test-retest tissue quantification repeatability is assessed by two consecutive MRF scans with distinct breathing patterns. Paired Student’s t-test is used for statistical significance analysis with a p-value threshold of 0.05. Main results: MR-MRF achieved successful reconstruction of motion-resolved tissue maps at EOE phase, with blinded radiologist assessment yielding an average score of 3 (moderate quality - sufficient for diagnosis) for overall image impression. The FWHM of organ boundaries in MR-MRF-derived tissue maps is 3.1mm ± 1.7mm, significantly lower than motion-blurred tissue maps (9.9mm ± 3.4mm, p-value<0.0001). Test-retest analysis demonstrated good repeatability: liver coefficient of variation was 5.5% ± 7.1% (T1), 8.2% ± 4.4% (T2), and 5.0% ± 2.0% (PD), with excellent linear agreement (R² = 0.96, 0.80, and 0.85 for T1, T2, and PD, respectively). Significance: This study establishes the technical foundation of MR-MRF to achieve repeatable and quantitative liver T1/T2/PD mapping under free-breathing conditions at 3T. The results validate the feasibility of addressing respiratory motion in abdominal multi-parametric quantitative MRI.
- Open Access
- 28 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235025
Enhanced 4D diffusion-weighted PROPELLER echo-planar imaging with collaborative blade reconstruction
Objective. Four-dimensional diffusion-weighted imaging (4D-DWI) offers enhanced soft-tissue contrast for image-guided radiotherapy (IGRT) compared to conventional 4D-magnetic resonance imaging. However, its clinical application has been hindered by geometric distortion or prolonged acquisition times. This study introduces an improved respiratory-correlated 4D-DWI technique to address these critical limitations. Approach. The proposed 4D-DW-PROP-EPI-JBCR technique consists of four stages: data acquisition, coil sensitivity and phase error maps estimation, retrospective data sorting, and a joint-blade collaborative reconstruction (JBCR) step. We evaluated its performance against the previous 4D-DW-PROPELLER-EPI using both simulations and in vivo experiments. Evaluation metrics included k -space uniformity requirements, point spread function (PSF) quality, minimum required sampling factor (SF), image quality, geometric fidelity, and acquisition time. Image quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity (SSIM), high-frequency error norm (HFEN), and signal-to-noise ratio (SNR); geometric fidelity was evaluated via Dice similarity coefficient (DSC) and Hausdorff distance (HD). Paired t -tests were used for metric comparisons, with statistical significance set at P < 0.05. Main results. Compared to 4D-DW-PROPELLER-EPI, the proposed 4D-DW-PROP-EPI-JBCR eliminated the requirement for strict k -space uniformity while achieving enhanced PSFs with fewer acquisitions. Additionally, 4D-DW-PROP-EPI-JBCR yielded significant improvements in image quality compared to 4D-DW-PROPELLER-EPI across all key metrics: SSIM (0.83–0.92 vs 0.81–0.90, P < 0.05), PSNR (20.56–25.20 vs 20.24–24.48, P < 0.05), HFEN (0.49–0.678 vs 0.52–0.80, P < 0.05), and SNR (31.1–32.6 dB vs 28.6–29.5 dB, P < 0.05). It also exhibited excellent geometric fidelity, as evidenced by DSC (0.90 ± 0.03) and HD (2.37 ± 1.12). Notably, these performance gains were achieved with an SF of 1.9 per diffusion direction, compared to the SF of 2.4 for 4D-DW-PROPELLER-EPI. Significance. By enabling distortion-free respiratory-correlated 4D-DWI and reducing SF by more than 20% compared to 4D-DW-PROPELLER-EPI, the 4D-DW-PROP-EPI-JBCR technique markedly improves the clinical utility of 4D-DWI for abdominal IGRT.
- 28 November 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235025
Open AccessEnhanced 4D diffusion-weighted PROPELLER echo-planar imaging with collaborative blade reconstruction
Objective. Four-dimensional diffusion-weighted imaging (4D-DWI) offers enhanced soft-tissue contrast for image-guided radiotherapy (IGRT) compared to conventional 4D-magnetic resonance imaging. However, its clinical application has been hindered by geometric distortion or prolonged acquisition times. This study introduces an improved respiratory-correlated 4D-DWI technique to address these critical limitations. Approach. The proposed 4D-DW-PROP-EPI-JBCR technique consists of four stages: data acquisition, coil sensitivity and phase error maps estimation, retrospective data sorting, and a joint-blade collaborative reconstruction (JBCR) step. We evaluated its performance against the previous 4D-DW-PROPELLER-EPI using both simulations and in vivo experiments. Evaluation metrics included k -space uniformity requirements, point spread function (PSF) quality, minimum required sampling factor (SF), image quality, geometric fidelity, and acquisition time. Image quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity (SSIM), high-frequency error norm (HFEN), and signal-to-noise ratio (SNR); geometric fidelity was evaluated via Dice similarity coefficient (DSC) and Hausdorff distance (HD). Paired t -tests were used for metric comparisons, with statistical significance set at P < 0.05. Main results. Compared to 4D-DW-PROPELLER-EPI, the proposed 4D-DW-PROP-EPI-JBCR eliminated the requirement for strict k -space uniformity while achieving enhanced PSFs with fewer acquisitions. Additionally, 4D-DW-PROP-EPI-JBCR yielded significant improvements in image quality compared to 4D-DW-PROPELLER-EPI across all key metrics: SSIM (0.83–0.92 vs 0.81–0.90, P < 0.05), PSNR (20.56–25.20 vs 20.24–24.48, P < 0.05), HFEN (0.49–0.678 vs 0.52–0.80, P < 0.05), and SNR (31.1–32.6 dB vs 28.6–29.5 dB, P < 0.05). It also exhibited excellent geometric fidelity, as evidenced by DSC (0.90 ± 0.03) and HD (2.37 ± 1.12). Notably, these performance gains were achieved with an SF of 1.9 per diffusion direction, compared to the SF of 2.4 for 4D-DW-PROPELLER-EPI. Significance. By enabling distortion-free respiratory-correlated 4D-DWI and reducing SF by more than 20% compared to 4D-DW-PROPELLER-EPI, the 4D-DW-PROP-EPI-JBCR technique markedly improves the clinical utility of 4D-DWI for abdominal IGRT.
- Open Access
- 24 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (6) , 2454-2471
Motion‐resolved four‐dimensional abdominal diffusion‐weighted imaging using PROPELLER EPI (4D‐DW‐PROPELLER‐EPI)
Purpose To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT).Methods An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting. A new k-space and blade (K-B) amplitude binning method was developed for the proposed 4D-DW-PROPELLER-EPI to optimize the number of blades and the k-space uniformity before performing conventional PROPELLER-EPI reconstruction, by using two metrics to evaluate the adequacy of the acquired data. The proposed 4D-DW-PROPELLER-EPI was preliminarily evaluated in both simulation experiments and in vivo experiments with varying frame rates and different numbers of repeated acquisition.Results The feasibility of achieving distortion-free 4D-DWI images by using the proposed 4D-DW-PROPELLER-EPI technique was demonstrated in both digital phantom and healthy subjects. Evaluation of the 4D completeness metrics shows that the K-B amplitude binning method could simultaneously improve the acquisition efficiency and data reconstruction performance for 4D-DW-PROPELLER-EPI.Conclusion 4D-DW-PROPELLER-EPI with K-B amplitude binning is an advanced technique that can provide distortion-free 4D-DWI images for resolving respiratory motion, and may benefit the application of image-guided abdominal RT.
- 24 July 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (6) , 2454-2471
Open AccessMotion‐resolved four‐dimensional abdominal diffusion‐weighted imaging using PROPELLER EPI (4D‐DW‐PROPELLER‐EPI)
Purpose To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT).Methods An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting. A new k-space and blade (K-B) amplitude binning method was developed for the proposed 4D-DW-PROPELLER-EPI to optimize the number of blades and the k-space uniformity before performing conventional PROPELLER-EPI reconstruction, by using two metrics to evaluate the adequacy of the acquired data. The proposed 4D-DW-PROPELLER-EPI was preliminarily evaluated in both simulation experiments and in vivo experiments with varying frame rates and different numbers of repeated acquisition.Results The feasibility of achieving distortion-free 4D-DWI images by using the proposed 4D-DW-PROPELLER-EPI technique was demonstrated in both digital phantom and healthy subjects. Evaluation of the 4D completeness metrics shows that the K-B amplitude binning method could simultaneously improve the acquisition efficiency and data reconstruction performance for 4D-DW-PROPELLER-EPI.Conclusion 4D-DW-PROPELLER-EPI with K-B amplitude binning is an advanced technique that can provide distortion-free 4D-DWI images for resolving respiratory motion, and may benefit the application of image-guided abdominal RT.