Matrixmidface Preformed Orbital Implants for Three-Dimensional Reconstruction of Orbital Floor and Medial Wall Fractures: A Prospective Clinical Study
Open Access
- 20 April 2023
- journal article
- research article
- Published by MDPI AG in Craniomaxillofacial Trauma & Reconstruction
- Vol. 17 (2) , 104-114
Abstract
Study Design: Prospective Interventional study Objective: To evaluate the efficiency of Matrixmidface preformed Orbital plates for three-dimensional reconstruction of orbital floor and medial wall fractures. Methods: This prospective institutional clinical study was conducted on a group of 14 patients who underwent repair of orbital floor and medial wall fracture defects using Matrixmidface Preformed Orbital plates and open reduction and internal fixation of associated fractures. The following parameters were studied preoperative and postoperative enophthalmos, hypoglobus, orbital volume; correction of diplopia, intraoperative and postoperative complications. Results: All 14 patients were males aged between 19 and 42 years. The most common mode of injury was found to be road traffic accidents (RTAs) followed by self-fall and trauma at workplace. Orbital fractures were associated with other concomitant maxillofacial fractures in 12 patients (85.7%) while 2 patients (14.3%) had pure blowout fractures. Significant improvement of enophthalmos was noted from preoperative period to 1 week, 6 weeks, and 6 months postoperatively ( P value .02, .01, and .01, respectively). Out of 11 patients with preoperative hypoglobus, 5 patients (45.45%) had persistent hypoglobus in the immediate postoperative period which reduced to 4 patients (36.36%) at 6 weeks postoperatively (p value .00). The postoperative orbital volume of fractured side ranged from 20.3 cm3 to 26.76 cm3 with a mean of 23.50 cm3 ± 1.74. The mean difference between the volumes of the repaired and uninjured sides was found to be .27 cm3 ± .39 ( P value .02) denoting that the reconstruction of the orbit closely approximated that of the uninjured side. Conclusions: The Matrixmidface Preformed Orbital plate provides exceptional reconstruction of the orbital blowout fracture defects and ensures satisfactory results clinically and radiographically. The plate ensures an approximate recreation of topographical anatomy of the orbit and adequately restores the orbital volume. It provides adequate correction of asymmetry, hypoglobus, enophthalmos and attempts to restore eye movements, without causing any significant postoperative complication.Keywords
This publication has 33 references indexed in Scilit:
- La voie d’abord combinée transcaronculaire-transconjonctivale dans l’approche des fractures orbitaires de la paroi médiale. Technique chirurgicaleRevue de Stomatologie et de Chirurgie Maxillo-faciale, 2010
- Accuracy and Predictability in Use of AO Three-Dimensionally Preformed Titanium Mesh Plates for Posttraumatic Orbital ReconstructionJournal of Craniofacial Surgery, 2009
- Principles of Facial TraumaJournal of Craniofacial Surgery, 2009
- Topographical CT-data analysis of the human orbital floorInternational Journal of Oral and Maxillofacial Surgery, 2007
- Individual preformed titanium meshes for orbital fracturesOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- Anatomical 3-dimensional Pre-bent Titanium Implant for Orbital Floor FracturesOphthalmology, 2006
- Repair of Medial Orbital Wall Fracture: Transcaruncular ApproachOrbit, 2005
- Normal changes in orbital volume during childhoodJournal of Neurosurgery, 2002
- Titanium mesh in orbital wall reconstructionInternational Journal of Oral and Maxillofacial Surgery, 1992
- Reconstruction of Internal Orbital Fractures with Vitallium MeshPlastic and Reconstructive Surgery, 1991