NCNeha Umakant Chodankar

Neha Umakant Chodankar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Neha Umakant Chodankar has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Augmented Reality Navigation Versus Patient-Specific Cutting Guides for Simulated Fronto-Orbital Surface Trajectories in Facial Feminization Surgery: A Preclinical Accuracy Study

    by Sead Abazi, Sophia Felicité Francisca Corten, Michel Beyer, Neha Umakant Chodankar, Alexandru Burde, Simon Meyer, Joachim Polligkeit, Florian M. Thieringer

    This preclinical investigation examined whether optical see-through augmented reality (AR) can transfer planned fronto-orbital cutting paths during simulated frontal debossing compared with patient-specific CAD/CAM cutting guides (CGs). Twenty printed skull replicas derived from one CT dataset were divided equally between workflows. Four superficial frontal or supraorbital grooves were created per skull and evaluated using postoperative CBCT and bidirectional closest-point distances. Overall deviation averaged the four trajectory means within each skull, giving 10 independent observations per group. Skull-level median [Q1, Q3] deviation was 0.543 [0.496, 0.588] mm with CGs and 1.098 [0.907, 1.333] mm with AR. Exact two-sided Mann–Whitney comparisons with Holm correction across overall accuracy, execution time, and four regions favored CGs for overall accuracy (adjusted p = 0.0208), superior frontal and right supraorbital accuracy, and execution time (adjusted p = 0.0029). The median [Q1, Q3] cumulative groove-execution time was 65.5 [61.5, 78.5] s with CGs and 152.0 [131.5, 208.8] s with AR. Mechanical guides deviated less with shorter groove-execution times in this standardized model, while operator and learning effects were not adjusted for. These findings concern surface trajectory reproduction in rigid models; clinical validation and assessment of the complete workflow are needed.

  • Open Access

    Fully Automated AI-Based Digital Workflow for Mirroring of Healthy and Defective Craniofacial Models

    by Michel Beyer, Julian Grossi, Alexandru Burde, Sead Abazi, Lukas Seifert, Joachim Polligkeit, Neha Umakant Chodankar, Florian M. Thieringer

    The accurate reconstruction of craniofacial defects requires the precise segmentation and mirroring of healthy anatomy. Conventional workflows rely on manual interaction, making them time-consuming and subject to operator variability. This study developed and validated a fully automated digital pipeline that integrates deep learning–based segmentation with algorithmic mirroring for craniofacial reconstruction. A total of 388 cranial CT scans were used to train a three-dimensional nnU-Net model for skull and mandible segmentation. A Principal Component Analysis–Iterative Closest Point (PCA–ICP) algorithm was then applied to compute the sagittal symmetry plane and perform mirroring. Automated results were compared with expert-generated segmentations and manually defined symmetry planes using Dice Similarity Coefficient (DSC), Mean Surface Distance (MSD), Hausdorff Distance (HD), and angular deviation. The nnU-Net achieved high segmentation accuracy for both the mandible (mean DSC 0.956) and the skull (mean DSC 0.965). Mirroring results showed minimal angular deviation from expert reference planes (mandible: 1.32° ± 0.71° in defect cases, 1.58° ± 1.12° in intact cases; skull: 1.75° ± 0.84° in defect cases, 1.15° ± 0.81° in intact cases). The presence of defects did not significantly affect accuracy. This automated workflow demonstrated robust performance and clinical applicability, offering standardized, reproducible, and time-efficient planning for craniofacial reconstruction.


  • Immunoglobulin G4 related sclerosing disease mimicking a lytic lesion of the mandible: a case report and review of literature

    by Neha Umakant Chodankar, Vikas Dhupar, Anita Dhupar, Francis Akkara

    Background Immunoglobulin G4 related disease (IgG4-RD) is an immune-mediated, multifocal, fibroinflammatory disease with varied clinical manifestations. The involvement of head and neck region is infrequent. The objective was to report a case of localized IgG4-RD of mandible that clinically mimicked a lytic lesion. Case presentation A 22 year old female presented with restricted mouth opening and swelling over right ramus and angle region of mandible. Radiographic imaging showed an ill-defined radiolucent lytic lesion infiltrating adjacent muscles. An incisional biopsy was performed and histopathological picture was suggestive of benign spindle cell neoplasm. Immunohistochemistry was suggestive of IgG4-RD involving mandible adjoining soft tissues. Elevated serum IgG4 levels were noted. Oral steroid therapy was initiated and tapered without maintenance dose. The patient progressed without any sequelae. Imaging 2 years after completion of treatment showed complete resolution of the radiolucent lesion. Conclusion The precise diagnosis of this lesion is challenging and depends on many different factors. A non-specific localized lesion should be investigated as a systemic condition. Early diagnosis and prompt initiation of steroid therapy should be favored. Continued follow up is critical due to the indolent nature of this disease. The future of management of this disease is the development of specific diagnostic criteria and targeted therapy of head & neck lesions.

  • Management of Isolated Medial Orbital Wall Fracture with Intraoral Periapical X-ray Film: A Case Report with Literature Review

    by Kime Nuyu, Neha Umakant Chodankar, Vathsalya Vijay, Vikas Dhupar, Francis Akkara

    Fractures of the walls of the orbit can cause a number of problems which include diplopia, extraocular muscle entrapment, enophthalmos, etc. Medial wall fractures are the most common among all orbital wall fractures, and their anatomical reconstruction is relatively challenging. Various autogenous and synthetic materials have been tried over the years, and each has its own advantages and limitations. In this case report, a 17-year-old male presented with an outward deviation of his left eye with binocular double vision since 18 days following a blunt injury with a tennis ball. He was diagnosed with a trapdoor fracture of the medial wall of the left orbit with entrapment of medial rectus muscle which was successfully managed by releasing the entrapped muscle and reconstructing the defect using an intraoral periapical X-ray film.

  • Surgical Anatomy in Orbital Fractures: A Surgeons Perspective

    by Neha Umakant Chodankar, Vikas Dhupar, Vathsalya Vijay, Nadia Fernandes

    Fractures of the orbit are frequently noted in craniomaxillofacial trauma. The complexity of the anatomy and the proximity to various vital structures often complicates the surgical management of these fractures. The authors have thus attempted to review the literature on anatomy of the bony orbit and its soft tissue envelope in a simplified manner with due emphasis on surgical anatomy and exploration of the orbit with a surgical perspective. The contents of this narrative literature review may be useful for young maxillofacial surgeons and will aid in the process of management of orbital fractures.


  • Changing Patterns of Zygomaticomaxillary Complex Fractures: A Retrospective Study

    by Neha Umakant Chodankar, Vikas Dhupar, Francis Akkara, Praveen Satish Kumar


  • Open Access

    Matrixmidface Preformed Orbital Implants for Three-Dimensional Reconstruction of Orbital Floor and Medial Wall Fractures: A Prospective Clinical Study

    by Neha Umakant Chodankar, Vikas Dhupar, Francis Akkara, Vathsalya Vijay

    Study Design: Prospective Interventional study Objective: To evaluate the efficiency of Matrixmidface preformed Orbital plates for three-dimensional reconstruction of orbital floor and medial wall fractures. Methods: This prospective institutional clinical study was conducted on a group of 14 patients who underwent repair of orbital floor and medial wall fracture defects using Matrixmidface Preformed Orbital plates and open reduction and internal fixation of associated fractures. The following parameters were studied preoperative and postoperative enophthalmos, hypoglobus, orbital volume; correction of diplopia, intraoperative and postoperative complications. Results: All 14 patients were males aged between 19 and 42 years. The most common mode of injury was found to be road traffic accidents (RTAs) followed by self-fall and trauma at workplace. Orbital fractures were associated with other concomitant maxillofacial fractures in 12 patients (85.7%) while 2 patients (14.3%) had pure blowout fractures. Significant improvement of enophthalmos was noted from preoperative period to 1 week, 6 weeks, and 6 months postoperatively ( P value .02, .01, and .01, respectively). Out of 11 patients with preoperative hypoglobus, 5 patients (45.45%) had persistent hypoglobus in the immediate postoperative period which reduced to 4 patients (36.36%) at 6 weeks postoperatively (p value .00). The postoperative orbital volume of fractured side ranged from 20.3 cm3 to 26.76 cm3 with a mean of 23.50 cm3 ± 1.74. The mean difference between the volumes of the repaired and uninjured sides was found to be .27 cm3 ± .39 ( P value .02) denoting that the reconstruction of the orbit closely approximated that of the uninjured side. Conclusions: The Matrixmidface Preformed Orbital plate provides exceptional reconstruction of the orbital blowout fracture defects and ensures satisfactory results clinically and radiographically. The plate ensures an approximate recreation of topographical anatomy of the orbit and adequately restores the orbital volume. It provides adequate correction of asymmetry, hypoglobus, enophthalmos and attempts to restore eye movements, without causing any significant postoperative complication.