Enhancing patient positioning precision: a comparative analysis of surface-guided radiation therapy systems
Authors:
- 19 July 2025
- journal article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (3) , 833-850
Abstract
This study evaluated the positioning precision of various surface-guided radiation therapy (SGRT) systems to enhance patient setup accuracy in radiotherapy. A female torso phantom (Electronics Research & Development Corporation) was employed to assess and compare the accuracy of four SGRT devices: AlignRT (Vision RT, United Kingdom), Catalyst (C-rad AB, Sweden), VOXELAN (Electronics Research&Development Corporation, Okayama, Japan) and ExacTrac Dynamic (Brainlab, Germany). The external body contour was used as a reference surface image. For positioning precision measurement, the treatment couch was moved in predetermined directions, distances, and angles and the amount of movement evaluated by the SGRT system was compared to the known amount. The results demonstrated that while all SGRT systems-maintained positioning errors within nominal precision thresholds (1 mm for translational movements and 1° for rotational movements), significant inter-device variability was observed. AlignRT and ExacTrac Dynamic exhibited superior accuracy across all movement categories. In contrast, Catalyst demonstrated a higher fraction of positioning errors (16.0%) in the abdominal region, primarily due to lower camera resolution and the use of a deformable registration algorithm. VOXELAN displayed increased errors in the anterior-posterior direction, likely due to interpolation-based surface estimation. These findings highlight the need for standardized evaluation protocols to ensure fair comparisons and improve clinical adoption of SGRT systems.Keywords
Funding Information
- Japanese Society of Radiological Technology
This publication has 28 references indexed in Scilit:
- Evaluation of technical performance of optical surface imaging system using conventional and novel stereotactic radiosurgery algorithmsJournal of Applied Clinical Medical Physics, 2020
- The Role of Optical Surface Imaging Systems in Radiation TherapySeminars in Radiation Oncology, 2018
- Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180Medical Physics, 2018
- Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 FractionsTechnology in Cancer Research & Treatment, 2018
- Evaluation of daily patient positioning for radiotherapy with a commercial 3D surface-imaging system (Catalyst™)Radiation Oncology, 2016
- Evaluation of a new six degrees of freedom couch for radiation therapyMedical Physics, 2013
- A novel surface imaging system for patient positioning and surveillance during radiotherapyStrahlentherapie und Onkologie, 2013
- Evaluation of the Accuracy of a 3D Surface Imaging System for Patient Setup in Head and Neck Cancer RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Quality assurance for image‐guided radiation therapy utilizing CT‐based technologies: A report of the AAPM TG‐179Medical Physics, 2012
- The management of imaging dose during image‐guided radiotherapy: Report of the AAPM Task Group 75Medical Physics, 2007