Takeshi Ohno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takeshi Ohno has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Fujio Araki
Department of Health Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, 862-0976, Japan
8 shared publications Takahiro Kubota
Kokura Memorial Hospital, 3-2-1 Asano, Kokura, Fukuoka, Japan
4 shared publicationsFujio Araki
Department of Health Sciences, Faculty of Life Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, Japan
3 shared publicationsMasayuki Yano
Saga Heavy Ion Medical Accelerator in Tosu, Koga-machi, Tosu, Saga, Japan
3 shared publicationsKento Hoshida
Graduate School of Health Sciences, Kumamoto University, 4-24-1 Kuhonji, Kumamoto, Japan
2 shared publicationsShotaro Ito
National Hospital Organization Kyushu Medical Center, 1-8-1 Jigyouhama, Fukuoka, Japan
2 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
A multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy
Background: Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the treatment room. Multicenter end‐to‐end data across commercial systems remain limited. Purpose: To evaluate static irradiation accuracy and setup time with two reference surfaces in a nationwide multicenter skin markerless SGRT postal audit. Methods: A prospective end‐to‐end postal audit was conducted from October 2023 to July 2025 at 40 Japanese institutions using five commercial SGRT systems (AlignRT, Catalyst, ExacTrac Dynamic, IDENTIFY, and VOXELAN), eight per system. Each institution received a common phantom package: a breast‐shaped surface phantom, two cubic phantoms containing gold markers, and radiochromic films. Markerless setup and irradiation were performed with both the DICOM and SGRT references; ExacTrac Dynamic institutions performed the DICOM reference setup only. Static irradiation accuracy was the difference between the film‐derived radiation center and the intended center in the DICOM RT Plan; the primary metric was the three‐dimensional translational vector error (3D vector error). Paired comparisons used the Wilcoxon signed‐rank test, and multivariable linear regression evaluated factors associated with both endpoints. Results: Critical setup errors exceeding 5 mm occurred at four institutions initially (institution‐level error rate, 10.0%; three with the DICOM and one with the SGRT reference); one DICOM reference setup was not remeasured and remained out of tolerance, and was excluded as an outlier, leaving 39 DICOM and 31 SGRT reference setups for analysis. Excluding ExacTrac Dynamic, the DICOM reference showed a significantly larger 3D vector error than the SGRT reference (1.54 ± 0.91 vs. 1.20 ± 0.61 mm, p = 0.043). Setup time did not differ between references (86.19 ± 43.57 vs. 81.61 ± 37.09 s, p = 0.804). Axis‐specifically, the difference between references was confined to the anterior–posterior direction (mean absolute difference 0.36 mm, p = 0.002), whereas a caudal superior–inferior offset was present with both (−0.50 ± 1.29 and −0.37 ± 0.87 mm; both p < 0.01) and did not differ between them ( p = 0.854). The 1‐camera condition was independently associated with a larger 3D vector error than the 3‐camera condition (β = 0.90 mm; 95% CI, 0.17–1.63 mm; p = 0.017); no factor was associated with setup time, which showed no correlation with 3D vector error. Conclusions: Skin markerless SGRT achieved millimeter‐level static irradiation accuracy but carried a non‐negligible risk of critical setup errors. The difference between the two reference workflows was confined to the anterior–posterior direction, whereas a superior–inferior offset common to both indicates a residual uncertainty in the audit chain itself. Reference surface selection and camera configuration influenced accuracy, whereas setup time was not a reliable surrogate. These findings highlight the importance of commissioning, standardized reference surface acquisition, routine QA, and independent third‐party audits.
- 29 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (11)
Open AccessA multicenter end‐to‐end postal audit of skin markerless surface‐guided radiation therapy
Background: Surface‐guided radiation therapy (SGRT) enables skin markerless positioning, but its accuracy may depend on the reference surface, hardware configuration, commissioning, and institutional workflow. Two reference surfaces are commonly used: a DICOM reference generated from planning CT images and an SGRT reference acquired in the treatment room. Multicenter end‐to‐end data across commercial systems remain limited. Purpose: To evaluate static irradiation accuracy and setup time with two reference surfaces in a nationwide multicenter skin markerless SGRT postal audit. Methods: A prospective end‐to‐end postal audit was conducted from October 2023 to July 2025 at 40 Japanese institutions using five commercial SGRT systems (AlignRT, Catalyst, ExacTrac Dynamic, IDENTIFY, and VOXELAN), eight per system. Each institution received a common phantom package: a breast‐shaped surface phantom, two cubic phantoms containing gold markers, and radiochromic films. Markerless setup and irradiation were performed with both the DICOM and SGRT references; ExacTrac Dynamic institutions performed the DICOM reference setup only. Static irradiation accuracy was the difference between the film‐derived radiation center and the intended center in the DICOM RT Plan; the primary metric was the three‐dimensional translational vector error (3D vector error). Paired comparisons used the Wilcoxon signed‐rank test, and multivariable linear regression evaluated factors associated with both endpoints. Results: Critical setup errors exceeding 5 mm occurred at four institutions initially (institution‐level error rate, 10.0%; three with the DICOM and one with the SGRT reference); one DICOM reference setup was not remeasured and remained out of tolerance, and was excluded as an outlier, leaving 39 DICOM and 31 SGRT reference setups for analysis. Excluding ExacTrac Dynamic, the DICOM reference showed a significantly larger 3D vector error than the SGRT reference (1.54 ± 0.91 vs. 1.20 ± 0.61 mm, p = 0.043). Setup time did not differ between references (86.19 ± 43.57 vs. 81.61 ± 37.09 s, p = 0.804). Axis‐specifically, the difference between references was confined to the anterior–posterior direction (mean absolute difference 0.36 mm, p = 0.002), whereas a caudal superior–inferior offset was present with both (−0.50 ± 1.29 and −0.37 ± 0.87 mm; both p < 0.01) and did not differ between them ( p = 0.854). The 1‐camera condition was independently associated with a larger 3D vector error than the 3‐camera condition (β = 0.90 mm; 95% CI, 0.17–1.63 mm; p = 0.017); no factor was associated with setup time, which showed no correlation with 3D vector error. Conclusions: Skin markerless SGRT achieved millimeter‐level static irradiation accuracy but carried a non‐negligible risk of critical setup errors. The difference between the two reference workflows was confined to the anterior–posterior direction, whereas a superior–inferior offset common to both indicates a residual uncertainty in the audit chain itself. Reference surface selection and camera configuration influenced accuracy, whereas setup time was not a reliable surrogate. These findings highlight the importance of commissioning, standardized reference surface acquisition, routine QA, and independent third‐party audits.
- 19 July 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (3) , 833-850
Enhancing patient positioning precision: a comparative analysis of surface-guided radiation therapy systems
This study evaluated the positioning precision of various surface-guided radiation therapy (SGRT) systems to enhance patient setup accuracy in radiotherapy. A female torso phantom (Electronics Research & Development Corporation) was employed to assess and compare the accuracy of four SGRT devices: AlignRT (Vision RT, United Kingdom), Catalyst (C-rad AB, Sweden), VOXELAN (Electronics Research&Development Corporation, Okayama, Japan) and ExacTrac Dynamic (Brainlab, Germany). The external body contour was used as a reference surface image. For positioning precision measurement, the treatment couch was moved in predetermined directions, distances, and angles and the amount of movement evaluated by the SGRT system was compared to the known amount. The results demonstrated that while all SGRT systems-maintained positioning errors within nominal precision thresholds (1 mm for translational movements and 1° for rotational movements), significant inter-device variability was observed. AlignRT and ExacTrac Dynamic exhibited superior accuracy across all movement categories. In contrast, Catalyst demonstrated a higher fraction of positioning errors (16.0%) in the abdominal region, primarily due to lower camera resolution and the use of a deformable registration algorithm. VOXELAN displayed increased errors in the anterior-posterior direction, likely due to interpolation-based surface estimation. These findings highlight the need for standardized evaluation protocols to ensure fair comparisons and improve clinical adoption of SGRT systems.
- 19 July 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (3) , 833-850
Enhancing patient positioning precision: a comparative analysis of surface-guided radiation therapy systems
This study evaluated the positioning precision of various surface-guided radiation therapy (SGRT) systems to enhance patient setup accuracy in radiotherapy. A female torso phantom (Electronics Research & Development Corporation) was employed to assess and compare the accuracy of four SGRT devices: AlignRT (Vision RT, United Kingdom), Catalyst (C-rad AB, Sweden), VOXELAN (Electronics Research&Development Corporation, Okayama, Japan) and ExacTrac Dynamic (Brainlab, Germany). The external body contour was used as a reference surface image. For positioning precision measurement, the treatment couch was moved in predetermined directions, distances, and angles and the amount of movement evaluated by the SGRT system was compared to the known amount. The results demonstrated that while all SGRT systems-maintained positioning errors within nominal precision thresholds (1 mm for translational movements and 1° for rotational movements), significant inter-device variability was observed. AlignRT and ExacTrac Dynamic exhibited superior accuracy across all movement categories. In contrast, Catalyst demonstrated a higher fraction of positioning errors (16.0%) in the abdominal region, primarily due to lower camera resolution and the use of a deformable registration algorithm. VOXELAN displayed increased errors in the anterior-posterior direction, likely due to interpolation-based surface estimation. These findings highlight the need for standardized evaluation protocols to ensure fair comparisons and improve clinical adoption of SGRT systems.
- 1 June 2021
- Published by Elsevier in Physica Medica
- Vol. 86, 19-30
Monte Carlo study of dosimetric impact of gadolinium contrast medium in transverse field MR-Linac system
- 1 June 2021
- Published by Elsevier in Physica Medica
- Vol. 86, 19-30
Monte Carlo study of dosimetric impact of gadolinium contrast medium in transverse field MR-Linac system
- 1 December 2020
- Published by Elsevier in Physica Medica
- Vol. 80, 65-74
Impact of lung density on isolated lung tumor dose in VMAT using inline MR-Linac
- 1 December 2020
- Published by Elsevier in Physica Medica
- Vol. 80, 65-74
Impact of lung density on isolated lung tumor dose in VMAT using inline MR-Linac
- 1 June 2020
- Published by Elsevier in Physica Medica
- Vol. 74, 100-109
Impact of the cavity on sinus wall dose in magnetic resonance image-guided radiation therapy
- 1 June 2020
- Published by Elsevier in Physica Medica
- Vol. 74, 100-109
Impact of the cavity on sinus wall dose in magnetic resonance image-guided radiation therapy
- 1 February 2020
- Published by Elsevier in Physica Medica
- Vol. 70, 153-160
Impact of transverse magnetic fields on dose response of a nanoDot OSLD in megavoltage photon beams
- 1 February 2020
- Published by Elsevier in Physica Medica
- Vol. 70, 153-160
Impact of transverse magnetic fields on dose response of a nanoDot OSLD in megavoltage photon beams
- 1 December 2019
- Published by Elsevier in Physica Medica
- Vol. 68, 17-34
Geant4 Monte Carlo investigation of the magnetic field effect on dose distributions in low-density regions in magnetic resonance image-guided radiation therapy
- 1 December 2019
- Published by Elsevier in Physica Medica
- Vol. 68, 17-34
Geant4 Monte Carlo investigation of the magnetic field effect on dose distributions in low-density regions in magnetic resonance image-guided radiation therapy
- 1 August 2019
- Published by Elsevier in Physica Medica
- Vol. 64, 74-80
Response of a nanoDot OSLD system in megavoltage photon beams
- 1 August 2019
- Published by Elsevier in Physica Medica
- Vol. 64, 74-80
Response of a nanoDot OSLD system in megavoltage photon beams
- 1 March 2019
- Published by Elsevier in Physica Medica
- Vol. 59, 112-116
Perturbation effect of parallel-plate ionization chambers on buildup dose measurements in transverse magnetic fields
- 1 March 2019
- Published by Elsevier in Physica Medica
- Vol. 59, 112-116
Perturbation effect of parallel-plate ionization chambers on buildup dose measurements in transverse magnetic fields