COMPARISON OF TWO LEG PHANTOMS CONTAINING 241AM IN BONE
Authors:
- Gary H. KramerGKGary H. Kramer
- Barry HauckBHBarry Hauck
- Kevin CapelloKCKevin Capello
- Werner RühmWRWerner Rühm
- Nabil El-FaramawyNENabil El-Faramawy
- David BroggioDBDavid Broggio
- Didier FranckDFDidier Franck
- Maria Antonia LopezMLMaria Antonia Lopez
- Teresa NavarroTNTeresa Navarro
- Juan Francisco NavarroJNJuan Francisco Navarro
- Begoña PerezBegoña Perez
- Sergei TolmachevSTSergei Tolmachev
- 1 September 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 101 (3) , 248-258
Abstract
Three facilities (CIEMAT, HMGU and HML) have used their in vivo counters to compare two leg phantoms. One was commercially produced with (241)Am activity artificially added to the bone inserts. The other, the United States Transuranium and Uranium Registries' (USTUR) leg phantom, was manufactured from (241)Am-contaminated bones resulting from an intake. The comparison of the two types of leg phantoms showed that the two phantoms are not similar in their activity distributions. An error in a bone activity estimate could be quite large if the commercial leg phantom is used to estimate what is contained in the USTUR leg phantom and, consequently, a real person. As the latter phantom was created as a result of a real contamination, it is deemed to be the more representative of what would actually happen if a person were internally contaminated with (241)Am.Keywords
This publication has 9 references indexed in Scilit:
- EURADOS intercomparison on measurements and Monte Carlo modelling for the assessment of americium in a USTUR leg phantomRadiation Protection Dosimetry, 2010
- THE CANADIAN NATIONAL CALIBRATION REFERENCE CENTER FOR BIOASSAY AND IN VIVO MONITORING: AN UPDATEHealth Physics, 2009
- Assessment of the internal dose of 241Am in bone by in vivo measurements of activity deposited in kneeRadiation Protection Dosimetry, 2007
- A Monte Carlo-based knee phantom for in vivo measurements of 241Am in boneNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Reconstruction of individual cumulative radon exposures by low-level in vivo measurements and biokinetic modelingJournal of Radioanalytical and Nuclear Chemistry, 2002
- A New Anthropometric Phantom for Calibrating in Vivo Measurements of Stable Lead in the Human Leg Using X-Ray FluorescenceHealth Physics, 2000
- The Canadian National Calibration Reference Center for Bioassay and In-vivo MonitoringHealth Physics, 1994
- Reconstruction of a Human Skull Calibration Phantom Using Bone Sections From an 241Am Exposure CaseHealth Physics, 1988
- The U.S. Transuranium Registry Report on the 241Am Content of a Whole BodyHealth Physics, 1985