Congruent Concavity Restoration of the Reconstructed Glenoid After the Latarjet Procedure
- 25 January 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (5) , 407-413
Abstract
Update: This article was updated on April 24, 2024 because of a previous omission, which was discovered after the preliminary version of the article was posted online. Specifically, the following blurb has been added to the first page of the PDF: “A Commentary by Inbo Kim, MD, PhD, is linked to the online version of this article.” Background: Few clinical studies have addressed concavity restoration by natural remodeling after a Latarjet procedure. This study investigated the fibrous tissue and osseous remodeling of the reconstructed glenoid and concavity restoration after a Latarjet procedure using postoperative computed tomographic arthrography (CTA). Methods: This retrospective study included 31 patients who underwent immediate postoperative computed tomographic (CT) scanning followed by CTA at 6 months postoperatively. We investigated whether fibrous tissue was newly created over the graft, whether the created fibrous tissue restored the congruity of the articular surface and the osseous remodeling of the graft to the glenoid level (whether the osseous portion of the graft was remodeled flush to the glenoid level) and the concavity of the glenoid using the radius of a best-fit circle on the articular surface, and the relationship between the amount of created fibrous tissue and the position of the graft. Results: In all patients, the fibrous tissue on the graft yielded a smooth articular surface, as revealed by the CTA. The mean radius of the entire glenoid, including the transferred graft, was significantly smaller (p = 0.010) at 33.2 ± 8.5 mm than that of the glenoid posterior to the osseous step-off at 37.6 ± 9.4 mm, which is presumed to be the glenoid before the surgical procedure. Despite the congruity of the articular surfaces due to fibrous tissue seen in the CTA, 14 (45%) of 31 patients showed a subchondral osseous step-off on either the medial side or the lateral side in the immediate postoperative CT scans. However, through osseous remodeling, 8 of the 10 grafts with a lateral step-off and 2 of the 4 grafts with a medial step-off converted to a flush position. The position of the step-off was correlated with the thickness of the fibrous tissue, with a tendency for thicker tissue in cases of a step-off on the medial side (p = 0.014). Conclusions: Fibrous tissue formation plus remodeling of the transferred graft resulted in the restoration of a congruent concavity after a Latarjet procedure by compensating for initially non-flush positioning of the graft. However, due to the small sample size in our study, clinical outcomes could not be correlated with radiographic findings, and our recommendation is to continue placing the graft as anatomically as possible. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 24 references indexed in Scilit:
- Iliac bone grafting of the intact glenoid improves shoulder stability with optimal graft positioningJournal of Shoulder and Elbow Surgery, 2015
- Long-term results of the Latarjet procedure for anterior instability of the shoulderJournal of Shoulder and Elbow Surgery, 2014
- Optimization of bone-block positioning in the Bristow-Latarjet procedure: A biomechanical studyOrthopaedics & Traumatology: Surgery & Research, 2014
- Does the presence of glenoid bone loss influence coracoid bone graft osteolysis after the Latarjet procedure? A computed tomography scan study in 2 groups of patients with and without glenoid bone lossJournal of Shoulder and Elbow Surgery, 2014
- The Stabilizing Mechanism of the Latarjet ProcedureJournal of Bone and Joint Surgery, 2013
- Risk factors for dislocation arthropathy after Latarjet procedure: a long-term studyInternational Orthopaedics, 2013
- Reconstruction of a Bony Bankart LesionThe American Journal of Sports Medicine, 2013
- Do the Traditional and Modified Latarjet Techniques Produce Equivalent Reconstruction Stability and Strength?The American Journal of Sports Medicine, 2012
- Normalization of Glenohumeral Articular Contact Pressures After Latarjet or Iliac Crest Bone-GraftingJournal of Bone and Joint Surgery, 2010
- One hundred eighteen Bristow-Latarjet repairs for recurrent anterior dislocation of the shoulder prospectively followed for fifteen years: Study II—the evolution of dislocation arthropathyJournal of Shoulder and Elbow Surgery, 2006