Joon-Ryul Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joon-Ryul Lim has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Yong-Min Chun
Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
14 shared publications - Tae-Hwan Yoon
Department of Orthopaedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
11 shared publications - Hsien-Hao Chang
Department of Orthopedic Surgery, National Health Insurance Service Ilsan Hospital, Goyang, Republic of Korea
4 shared publications - Yong-Jun Lee
Department of Orthopedic Surgery, Arthroscopy and Joint Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
3 shared publications - Jee-Hoon Choi
Arthroscopy and Joint Research Institute, Department of Orthopaedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
2 shared publications - Seung-Hwan Shin
Arthroscopy and Joint Research Institute, Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
2 shared publications
Latest Publications
- 20 April 2026
- Published by Wiley in Arthroscopy
Open Antegrade Muscle Advancement Reduces Retear Rates Compared to Arthroscopic Repair With Intra‐articular Release in Subscapularis Tears With Advanced Fatty Infiltration
Purpose: To compare arthroscopic repair without muscle advancement and open repair with muscle advancement in subscapularis tendon tears with fatty infiltration of Goutallier grade III or IV. Methods: This study retrospectively investigated patients with subscapularis tears and advanced fatty infiltration of Goutallier grade III or IV between March 2009 and October 2022. Inclusion criteria were pre‐ and postoperative radiologic evaluation and a minimum of 2‐year follow‐up. Exclusion criteria included partial repair, double‐row suture bridge repair, and advanced glenohumeral osteoarthritis. Patients who underwent arthroscopic subscapularis repair were compared with those who underwent open subscapularis repair with antegrade muscle advancement based on clinical scores (visual analog scale pain score, subjective shoulder value, American Shoulder and Elbow Surgeons shoulder score, and the University of California, Los Angeles shoulder score), range of motion (forward flexion, external and internal rotation), internal rotation strength (modified belly‐press test), and retear rate assessed by magnetic resonance arthrography. A subgroup analysis was performed in patients with isolated subscapularis tears, comparing clinical scores and retear rates between the two groups. Continuous variables were compared using t‐tests, and categorical variables were compared using chi‐square or Fisher's exact tests; Welch's t‐test was used for subgroup analyses. Results: The study included 170 patients; 112 patients underwent arthroscopic repair and 58 patients underwent open repair. Baseline characteristics were not different between the groups. The clinical scores did not differ between the groups preoperatively or at 2 years postoperatively. The proportion of patients achieving the minimal clinically important difference for American Shoulder and Elbow Surgeons was similar between groups (91.4% open vs. 88.4% arthroscopic, P = .549). Patient acceptable symptom state achievement did not differ significantly (72.4% open vs. 62.5% arthroscopic, P = .196). The modified belly‐press test score and the range of motion for internal rotation were both significantly better in the open repair group compared to the arthroscopic repair group at 2 years after surgery ( P = .011 and P = .021, respectively), whereas no difference was observed preoperatively. The retear rate was lower for open repair than for arthroscopic repair (51.7% vs. 76.8%, respectively; P < .001). In the subgroup of isolated subscapularis tears (n = 49; 33 arthroscopic and 16 open repairs), the clinical scores did not differ between the groups preoperatively or at 2 years postoperatively. The modified belly‐press test score and the range of motion for internal rotation were both significantly better in the open repair group ( P < .001 and P = .007, respectively). The retear rate was lower with open repair than with arthroscopic repair (37.5% vs. 75.8%, P = .009). Conclusions: For subscapularis tendon tears with advanced fatty infiltration, open repair with antegrade muscle advancement may be a superior alternative to arthroscopic repair without muscle advancement, potentially resulting in lower retear rates and improved clinical outcomes. However, patient‐reported outcomes did not significantly differ between the 2 approaches. Level of Evidence: Level III, retrospective comparative study.
- 20 April 2026
- Published by Wiley in Arthroscopy
Open Antegrade Muscle Advancement Reduces Retear Rates Compared to Arthroscopic Repair With Intra‐articular Release in Subscapularis Tears With Advanced Fatty Infiltration
Purpose: To compare arthroscopic repair without muscle advancement and open repair with muscle advancement in subscapularis tendon tears with fatty infiltration of Goutallier grade III or IV. Methods: This study retrospectively investigated patients with subscapularis tears and advanced fatty infiltration of Goutallier grade III or IV between March 2009 and October 2022. Inclusion criteria were pre‐ and postoperative radiologic evaluation and a minimum of 2‐year follow‐up. Exclusion criteria included partial repair, double‐row suture bridge repair, and advanced glenohumeral osteoarthritis. Patients who underwent arthroscopic subscapularis repair were compared with those who underwent open subscapularis repair with antegrade muscle advancement based on clinical scores (visual analog scale pain score, subjective shoulder value, American Shoulder and Elbow Surgeons shoulder score, and the University of California, Los Angeles shoulder score), range of motion (forward flexion, external and internal rotation), internal rotation strength (modified belly‐press test), and retear rate assessed by magnetic resonance arthrography. A subgroup analysis was performed in patients with isolated subscapularis tears, comparing clinical scores and retear rates between the two groups. Continuous variables were compared using t‐tests, and categorical variables were compared using chi‐square or Fisher's exact tests; Welch's t‐test was used for subgroup analyses. Results: The study included 170 patients; 112 patients underwent arthroscopic repair and 58 patients underwent open repair. Baseline characteristics were not different between the groups. The clinical scores did not differ between the groups preoperatively or at 2 years postoperatively. The proportion of patients achieving the minimal clinically important difference for American Shoulder and Elbow Surgeons was similar between groups (91.4% open vs. 88.4% arthroscopic, P = .549). Patient acceptable symptom state achievement did not differ significantly (72.4% open vs. 62.5% arthroscopic, P = .196). The modified belly‐press test score and the range of motion for internal rotation were both significantly better in the open repair group compared to the arthroscopic repair group at 2 years after surgery ( P = .011 and P = .021, respectively), whereas no difference was observed preoperatively. The retear rate was lower for open repair than for arthroscopic repair (51.7% vs. 76.8%, respectively; P < .001). In the subgroup of isolated subscapularis tears (n = 49; 33 arthroscopic and 16 open repairs), the clinical scores did not differ between the groups preoperatively or at 2 years postoperatively. The modified belly‐press test score and the range of motion for internal rotation were both significantly better in the open repair group ( P < .001 and P = .007, respectively). The retear rate was lower with open repair than with arthroscopic repair (37.5% vs. 75.8%, P = .009). Conclusions: For subscapularis tendon tears with advanced fatty infiltration, open repair with antegrade muscle advancement may be a superior alternative to arthroscopic repair without muscle advancement, potentially resulting in lower retear rates and improved clinical outcomes. However, patient‐reported outcomes did not significantly differ between the 2 approaches. Level of Evidence: Level III, retrospective comparative study.
- Open Access
- 13 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Tetranectin is significantly elevated in the synovial fluid of patients with full-thickness rotator cuff tears
Rotator cuff tears are one of the most common shoulder disorders and can lead to pain, weakness, and limited mobility. Although the clinical condition has been widely studied, its molecular mechanisms are still not fully understood. In this exploratory study, we analyzed the proteomic profile of synovial fluid in patients with full-thickness rotator cuff tears and compared the results to those from a control group. Proteomic analysis was performed on synovial fluid samples from seven patients with full-thickness tears and three patients with partial-thickness tears, who served as the control group. Label-free quantification using the MaxQuant platform identified 284 proteins at 1% FDR. Among them, CLEC3B (tetranectin) showed the most significant difference, with a fold change of 40.35 and a p-value of 2.6 × 10⁻³. Tetranectin exhibited a large effect size (Hedges’ g = 2.53), suggesting that it could be a potential candidate protein associated with full-thickness rotator cuff tear severity. Gene ontology enrichment analysis revealed biological processes related to extracellular matrix remodeling, fibrinolysis, and inflammation. Given its known roles in extracellular matrix remodeling, tetranectin was identified as a potential candidate protein associated with full-thickness rotator cuff tear, providing insight into pathological processes such as tendon degeneration and fatty infiltration.
- 13 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessTetranectin is significantly elevated in the synovial fluid of patients with full-thickness rotator cuff tears
Rotator cuff tears are one of the most common shoulder disorders and can lead to pain, weakness, and limited mobility. Although the clinical condition has been widely studied, its molecular mechanisms are still not fully understood. In this exploratory study, we analyzed the proteomic profile of synovial fluid in patients with full-thickness rotator cuff tears and compared the results to those from a control group. Proteomic analysis was performed on synovial fluid samples from seven patients with full-thickness tears and three patients with partial-thickness tears, who served as the control group. Label-free quantification using the MaxQuant platform identified 284 proteins at 1% FDR. Among them, CLEC3B (tetranectin) showed the most significant difference, with a fold change of 40.35 and a p-value of 2.6 × 10⁻³. Tetranectin exhibited a large effect size (Hedges’ g = 2.53), suggesting that it could be a potential candidate protein associated with full-thickness rotator cuff tear severity. Gene ontology enrichment analysis revealed biological processes related to extracellular matrix remodeling, fibrinolysis, and inflammation. Given its known roles in extracellular matrix remodeling, tetranectin was identified as a potential candidate protein associated with full-thickness rotator cuff tear, providing insight into pathological processes such as tendon degeneration and fatty infiltration.
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (6) , 922-929
Comparative Analysis of Minimally Invasive Versus Open Reduction Plate Osteosynthesis Using a Superior Clavicle Plate in Clavicle Shaft Fractures
Lim JR, et al. Clin Orthop Surg. 2025 Dec;17(6):922-929. https://doi.org/10.4055/cios24406
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (6) , 922-929
Open AccessComparative Analysis of Minimally Invasive Versus Open Reduction Plate Osteosynthesis Using a Superior Clavicle Plate in Clavicle Shaft Fractures
Lim JR, et al. Clin Orthop Surg. 2025 Dec;17(6):922-929. https://doi.org/10.4055/cios24406
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (5) , 740-746
Can the Inverted Application of the PHILOS Plate Be an Alternative in Extra-articular Distal Humerus Fractures? A Comparative Analysis with the Extra-articular Distal Humerus Plate
Lee YJ, et al. Clin Orthop Surg. 2025 Oct;17(5):740-746. https://doi.org/10.4055/cios25137
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (5) , 740-746
Open AccessCan the Inverted Application of the PHILOS Plate Be an Alternative in Extra-articular Distal Humerus Fractures? A Comparative Analysis with the Extra-articular Distal Humerus Plate
Lee YJ, et al. Clin Orthop Surg. 2025 Oct;17(5):740-746. https://doi.org/10.4055/cios25137
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (3) , 453-459
Concomitant Rotator Cuff Tear with Frozen Shoulder: A Contemplation on the Necessity and Legitimacy of Magnetic Resonance Imaging Stratified by Age
Chang HH, et al. Clin Orthop Surg. 2024 Nov;16:e69. https://doi.org/10.4055/cios24240
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (3) , 453-459
Open AccessConcomitant Rotator Cuff Tear with Frozen Shoulder: A Contemplation on the Necessity and Legitimacy of Magnetic Resonance Imaging Stratified by Age
Chang HH, et al. Clin Orthop Surg. 2024 Nov;16:e69. https://doi.org/10.4055/cios24240
- 23 August 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (19) , 1750-1756
Lateral Wall Integrity of the Greater Tuberosity Is Important for the Stability of Osteoporotic Proximal Humeral Fractures After Plate Fixation
Background: Previous studies assessing surgical fixation of osteoporotic proximal humeral fractures have primarily focused on medial calcar support. In this study, we utilized a specific model for 2-part surgical neck fracture of the osteoporotic proximal humerus to investigate how severe comminution of the greater tuberosity (GT) lateral wall affects biomechanical stability after fixation with a plate. Methods: Ten matched pairs of cadaveric humeri (right and left) were assigned to either a surgical neck fracture alone (the SN group) or a surgical neck fracture with GT lateral wall comminution (the LW group) with use of block randomization. We removed 5 mm of the lateral wall of the GT to simulate severe comminution of the lateral wall. Axial compression stiffness, torsional stiffness, varus bending stiffness, and the single load to failure in varus bending were measured for all plate-bone constructs. Results: Compared with the SN group, the LW group showed a significant decrease in all measures, including torsional stiffness (internal, p = 0.007; external, p = 0.007), axial compression stiffness (p = 0.002), and varus bending stiffness (p = 0.007). In addition, the mean single load to failure in varus bending for the LW group was 62% lower than that for the SN group (p = 0.005). Conclusions: Severe comminution of the GT lateral wall significantly compromised the biomechanical stability of osteoporotic, comminuted humeral surgical neck fractures. Clinical Relevance: Although the generalizability of this cadaveric model may be limited to the extreme clinical scenario, the model showed that severe comminution of the GT lateral wall significantly compromised the stability of osteoporotic humeral surgical neck fractures fixed with a plate and screws alone.
- 23 August 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (19) , 1750-1756
Lateral Wall Integrity of the Greater Tuberosity Is Important for the Stability of Osteoporotic Proximal Humeral Fractures After Plate Fixation
Background: Previous studies assessing surgical fixation of osteoporotic proximal humeral fractures have primarily focused on medial calcar support. In this study, we utilized a specific model for 2-part surgical neck fracture of the osteoporotic proximal humerus to investigate how severe comminution of the greater tuberosity (GT) lateral wall affects biomechanical stability after fixation with a plate. Methods: Ten matched pairs of cadaveric humeri (right and left) were assigned to either a surgical neck fracture alone (the SN group) or a surgical neck fracture with GT lateral wall comminution (the LW group) with use of block randomization. We removed 5 mm of the lateral wall of the GT to simulate severe comminution of the lateral wall. Axial compression stiffness, torsional stiffness, varus bending stiffness, and the single load to failure in varus bending were measured for all plate-bone constructs. Results: Compared with the SN group, the LW group showed a significant decrease in all measures, including torsional stiffness (internal, p = 0.007; external, p = 0.007), axial compression stiffness (p = 0.002), and varus bending stiffness (p = 0.007). In addition, the mean single load to failure in varus bending for the LW group was 62% lower than that for the SN group (p = 0.005). Conclusions: Severe comminution of the GT lateral wall significantly compromised the biomechanical stability of osteoporotic, comminuted humeral surgical neck fractures. Clinical Relevance: Although the generalizability of this cadaveric model may be limited to the extreme clinical scenario, the model showed that severe comminution of the GT lateral wall significantly compromised the stability of osteoporotic humeral surgical neck fractures fixed with a plate and screws alone.
- Open Access
- 22 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (7) , 1845
Continuous Superior Trunk Block versus Single-Shot Superior Trunk Block with Intravenous Dexmedetomidine for Postoperative Analgesia in Arthroscopic Shoulder Surgery: A Prospective Randomized Controlled Trial
Background/Objectives: Intravenous dexmedetomidine (DEX) can increase the analgesia duration of peripheral nerve block; however, its effect in combination with superior trunk block (STB) remains unclear. We examined whether combining single-shot STB (SSTB) with intravenous DEX would provide noninferior postoperative analgesia comparable to that provided by continuous STB (CSTB). Methods: Ninety-two patients scheduled for elective arthroscopic rotator cuff repair were enrolled in this prospective randomized trial. Patients were randomly assigned to the CSTB or SSTB + DEX group. Postoperatively, each CSTB group patient received 15 mL of 0.5% ropivacaine and a continuous 0.2% ropivacaine infusion. Each SSTB group patient received a 15 mL postoperative bolus injection of 0.5% ropivacaine. DEX was administered at 2 mcg/kg for 30 min post anesthesia, then maintained at 0.5 mcg/kg/h till surgery ended. Pain scores were investigated every 12 h for 48 h post operation, with evaluation of rebound pain incidence and opioid consumption. Results: The SSTB + DEX group had significantly higher median pain scores at 12 h post operation (resting pain, 8.0 vs. 3.0; movement pain, 8.0 vs. 5.0) and a higher incidence of rebound pain (56% vs. 20%) than the CSTB group. However, no significant between-group differences were observed in pain scores postoperatively at 24, 36, or 48 h. The CSTB group required less opioids and fewer rescue analgesics within 12–24 h post operation than the SSTB + DEX group. Conclusions: Compared with CSTB, SSTB + DEX required additional adjuvant or multimodal analgesics to reduce the risk and intensity of postoperative rebound pain in patients who underwent arthroscopic rotator cuff repair.
- 22 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (7) , 1845
Open AccessContinuous Superior Trunk Block versus Single-Shot Superior Trunk Block with Intravenous Dexmedetomidine for Postoperative Analgesia in Arthroscopic Shoulder Surgery: A Prospective Randomized Controlled Trial
Background/Objectives: Intravenous dexmedetomidine (DEX) can increase the analgesia duration of peripheral nerve block; however, its effect in combination with superior trunk block (STB) remains unclear. We examined whether combining single-shot STB (SSTB) with intravenous DEX would provide noninferior postoperative analgesia comparable to that provided by continuous STB (CSTB). Methods: Ninety-two patients scheduled for elective arthroscopic rotator cuff repair were enrolled in this prospective randomized trial. Patients were randomly assigned to the CSTB or SSTB + DEX group. Postoperatively, each CSTB group patient received 15 mL of 0.5% ropivacaine and a continuous 0.2% ropivacaine infusion. Each SSTB group patient received a 15 mL postoperative bolus injection of 0.5% ropivacaine. DEX was administered at 2 mcg/kg for 30 min post anesthesia, then maintained at 0.5 mcg/kg/h till surgery ended. Pain scores were investigated every 12 h for 48 h post operation, with evaluation of rebound pain incidence and opioid consumption. Results: The SSTB + DEX group had significantly higher median pain scores at 12 h post operation (resting pain, 8.0 vs. 3.0; movement pain, 8.0 vs. 5.0) and a higher incidence of rebound pain (56% vs. 20%) than the CSTB group. However, no significant between-group differences were observed in pain scores postoperatively at 24, 36, or 48 h. The CSTB group required less opioids and fewer rescue analgesics within 12–24 h post operation than the SSTB + DEX group. Conclusions: Compared with CSTB, SSTB + DEX required additional adjuvant or multimodal analgesics to reduce the risk and intensity of postoperative rebound pain in patients who underwent arthroscopic rotator cuff repair.
- 20 March 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (10) , 869-878
Heated Tobacco Products Have Detrimental Effects on Rotator Cuff Healing, Similar to Conventional Cigarettes
Background: Cigarette smoking impairs rotator cuff healing, but no study, to our knowledge, has focused on the association between heated tobacco products and rotator cuff tears. Methods: This study retrospectively investigated 1,133 patients who underwent arthroscopic repair of symptomatic rotator cuff tears between March 2011 and April 2021. Patients were grouped on the basis of their smoking patterns as nonsmokers, cigarette smokers, and heated tobacco smokers. Propensity score matching was used to reduce selection bias, and 45 subjects were selected from each group via 1:1:1 matching. Functional scores and active range of motion were compared among the 3 groups preoperatively and at a 2-year follow-up. Postoperative magnetic resonance imaging was performed 6 months after the surgical procedure to assess structural integrity. Results: Except for sex, similar baseline characteristics were achieved after propensity score matching. There were no differences in the clinical scores or range of motion between the matched groups either preoperatively or at the 2-year follow-up. However, the retear rate for the matched nonsmoker group was significantly lower (8.9%) than those for the matched cigarette smoker group (31.1%) and the heated tobacco smoker group (28.9%) (p = 0.022). Multivariable logistic regression analysis revealed that the retear rates were 3.403 times higher for the cigarette smoker group and 3.397 times higher for the heated tobacco smoker group than that for the nonsmoker group. Conclusions: Heated tobacco users, like conventional cigarette smokers, have worse clinical outcomes with respect to rotator cuff healing than nonsmokers. Regardless of the type of cigarette, abstinence from smoking is necessary for patients undergoing rotator cuff repair surgery. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 20 March 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (10) , 869-878
Heated Tobacco Products Have Detrimental Effects on Rotator Cuff Healing, Similar to Conventional Cigarettes
Background: Cigarette smoking impairs rotator cuff healing, but no study, to our knowledge, has focused on the association between heated tobacco products and rotator cuff tears. Methods: This study retrospectively investigated 1,133 patients who underwent arthroscopic repair of symptomatic rotator cuff tears between March 2011 and April 2021. Patients were grouped on the basis of their smoking patterns as nonsmokers, cigarette smokers, and heated tobacco smokers. Propensity score matching was used to reduce selection bias, and 45 subjects were selected from each group via 1:1:1 matching. Functional scores and active range of motion were compared among the 3 groups preoperatively and at a 2-year follow-up. Postoperative magnetic resonance imaging was performed 6 months after the surgical procedure to assess structural integrity. Results: Except for sex, similar baseline characteristics were achieved after propensity score matching. There were no differences in the clinical scores or range of motion between the matched groups either preoperatively or at the 2-year follow-up. However, the retear rate for the matched nonsmoker group was significantly lower (8.9%) than those for the matched cigarette smoker group (31.1%) and the heated tobacco smoker group (28.9%) (p = 0.022). Multivariable logistic regression analysis revealed that the retear rates were 3.403 times higher for the cigarette smoker group and 3.397 times higher for the heated tobacco smoker group than that for the nonsmoker group. Conclusions: Heated tobacco users, like conventional cigarette smokers, have worse clinical outcomes with respect to rotator cuff healing than nonsmokers. Regardless of the type of cigarette, abstinence from smoking is necessary for patients undergoing rotator cuff repair surgery. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 21 February 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (9) , 817-822
Comparing the Biomechanical Stability of Cerclage Cable with Plate Insert Versus Locking Screw in Periprosthetic Humeral Fracture
Background: In the setting of periprosthetic humeral fractures, the humeral stem of the implant represents a substantial challenge to the optimal method of proximal fixation. This study aimed to compare the initial biomechanical stability provided by cerclage cables with a locking plate insert versus bicortical locking screws (i.e., the gold standard for fixation) in fresh cadaveric humeri. Methods: After calculating the sample size, we utilized 10 sets of cadaveric specimens and created a 5-mm osteotomy gap 120 mm distal to the tip of the greater tuberosity, simulating a Wright and Cofield type-B periprosthetic humeral fracture on each specimen. Using 3 locking screws for distal fragment fixation, identical in all specimens, the specimens were assigned to Group A (3 cerclage cables with a plate insert) or Group B (3 locking bicortical screws) for proximal fragment fixation. Biomechanical tests included stiffness in varus and valgus bending, torsion, and axial compression, and a single load to failure. Results: No significant differences were observed in the biomechanical metrics between the 2 groups. Conclusions: Our study revealed that fixation with use of cerclage cables with a plate insert demonstrated biomechanical stability comparable with that of bicortical locking screw fixation when addressing the proximal fragment in Wright and Cofield type-B periprosthetic humeral fractures. Clinical Relevance: For proximal fragment fixation of periprosthetic humeral fractures, cerclage cables with a plate insert can be utilized as an effective fixation method that offers initial fixation strength that is comparable to the use of 3 locking bicortical screws.
- 21 February 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (9) , 817-822
Comparing the Biomechanical Stability of Cerclage Cable with Plate Insert Versus Locking Screw in Periprosthetic Humeral Fracture
Background: In the setting of periprosthetic humeral fractures, the humeral stem of the implant represents a substantial challenge to the optimal method of proximal fixation. This study aimed to compare the initial biomechanical stability provided by cerclage cables with a locking plate insert versus bicortical locking screws (i.e., the gold standard for fixation) in fresh cadaveric humeri. Methods: After calculating the sample size, we utilized 10 sets of cadaveric specimens and created a 5-mm osteotomy gap 120 mm distal to the tip of the greater tuberosity, simulating a Wright and Cofield type-B periprosthetic humeral fracture on each specimen. Using 3 locking screws for distal fragment fixation, identical in all specimens, the specimens were assigned to Group A (3 cerclage cables with a plate insert) or Group B (3 locking bicortical screws) for proximal fragment fixation. Biomechanical tests included stiffness in varus and valgus bending, torsion, and axial compression, and a single load to failure. Results: No significant differences were observed in the biomechanical metrics between the 2 groups. Conclusions: Our study revealed that fixation with use of cerclage cables with a plate insert demonstrated biomechanical stability comparable with that of bicortical locking screw fixation when addressing the proximal fragment in Wright and Cofield type-B periprosthetic humeral fractures. Clinical Relevance: For proximal fragment fixation of periprosthetic humeral fractures, cerclage cables with a plate insert can be utilized as an effective fixation method that offers initial fixation strength that is comparable to the use of 3 locking bicortical screws.
- Open Access
- 31 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 825
The Treatment of Periprosthetic Fracture Revision of the Humerus with “Bamboo Support” Structural Allograft Technique—Atrophic Non-Union of a Post-Operative Periprosthetic Fracture after Reverse Total Shoulder Arthroplasty: A Case Report
Periprosthetic fractures are a serious complication of joint replacement surgery. With the growing prevalence of reverse total shoulder arthroplasty (RTSA), the incidence of relatively uncommon periprosthetic humeral fractures has increased. Here, we present the unique case of a 74-year-old woman who developed atrophic non-union after plate osteosynthesis for a periprosthetic fracture associated with RTSA. Fixation failure was evident 3 months after the surgical intervention; the patient underwent a 3-month course of arm sling immobilization. However, bone resorption continued, and varus angulation of the fracture developed. In this case, surgical strategy involved the use of long proximal humerus internal locked system plate (DePuy Synthes, Paoli, PA, USA), augmented with autologous iliac bone graft and allogenic humerus structural bone graft with the “bamboo support technique”, fixed with Cable System (DePuy Synthes, Paoli, PA, USA). No reports have addressed the management of failed periprosthetic fractures using allogeneic humeral strut bone grafts. This report aims to fill the gap by presenting a novel surgical technique for the management of periprosthetic fractures associated with RTSA in case of treatment failure.
- 31 January 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (3) , 825
Open AccessThe Treatment of Periprosthetic Fracture Revision of the Humerus with “Bamboo Support” Structural Allograft Technique—Atrophic Non-Union of a Post-Operative Periprosthetic Fracture after Reverse Total Shoulder Arthroplasty: A Case Report
Periprosthetic fractures are a serious complication of joint replacement surgery. With the growing prevalence of reverse total shoulder arthroplasty (RTSA), the incidence of relatively uncommon periprosthetic humeral fractures has increased. Here, we present the unique case of a 74-year-old woman who developed atrophic non-union after plate osteosynthesis for a periprosthetic fracture associated with RTSA. Fixation failure was evident 3 months after the surgical intervention; the patient underwent a 3-month course of arm sling immobilization. However, bone resorption continued, and varus angulation of the fracture developed. In this case, surgical strategy involved the use of long proximal humerus internal locked system plate (DePuy Synthes, Paoli, PA, USA), augmented with autologous iliac bone graft and allogenic humerus structural bone graft with the “bamboo support technique”, fixed with Cable System (DePuy Synthes, Paoli, PA, USA). No reports have addressed the management of failed periprosthetic fractures using allogeneic humeral strut bone grafts. This report aims to fill the gap by presenting a novel surgical technique for the management of periprosthetic fractures associated with RTSA in case of treatment failure.