Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and Correction of Concomitant Dephasing and Diffusion Weighting
Open Access
- 11 June 2026
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (3) , 1178-1191
Abstract
Purpose: Deleterious effects from concomitant gradients are amplified at lower field strengths and stronger gradients. We aimed to show the signal errors caused by concomitant gradients across a wide range of hardware configurations and propose corrections that can be applied during experimental design and analysis. Theory and Methods: We derived a compact but accurate expression for concomitant gradients and simulated the associated signal bias across field strengths (0.03‐7 T) and gradient amplitudes (20‐600 mT/m) for asymmetric Maxwell‐compensated diffusion encoding gradient waveforms. Bias was assigned to “concomitant dephasing” or “concomitant diffusion weighting.” Concomitant dephasing was reduced by waveform correction that was deployed in the design stage. Concomitant diffusion weighting could be accounted for by using the actual gradient waveform during analysis. Results: Concomitant dephasing was caused by loss of Maxwell compensation during waveform resampling, with signal errors up to 100%, especially at low B 0 and high g max . Our waveform correction yielded a categorical improvement to signal accuracy, reducing bias to < 1% for most systems. However, bias at extreme B 0 ‐ g max ‐combinations remained > 1% (e.g., B 0 = 3 T and g max = 600 mT/m). Concomitant diffusion weighting caused biases above 1% at across all simulated MRI systems. Conclusion: Concomitant gradients have a relevant impact on signal accuracy, especially at low fields and ultra‐strong gradients. Concomitant dephasing must be considered for asymmetric waveforms, but can be largely suppressed by our correction method. Concomitant diffusion weighting is always present, regardless of waveform symmetry, but has a smaller impact and can be accounted for in the analysis.Keywords
Funding Information
- Vetenskapsrådet (2021‐04844)
- Cancerfonden (220592JIA)
- Cancerfonden (222011Pj)
- Crafoordska Stiftelsen (20240791)
This publication has 37 references indexed in Scilit:
- Concomitant field terms for asymmetric gradient coils: Consequences for diffusion, flow, and echo‐planar imagingMagnetic Resonance in Medicine, 2008
- Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion‐weighted imagingMagnetic Resonance in Medicine, 2003
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- Correction of concomitant magnetic field‐induced image artifacts in nonaxial echo‐planar imagingMagnetic Resonance in Medicine, 2002
- Artifacts induced by concomitant magnetic field in fast spin‐echo imagingMagnetic Resonance in Medicine, 1998
- Concomitant magnetic‐field‐induced artifacts in axial echo planar imagingMagnetic Resonance in Medicine, 1998
- Concomitant gradient terms in phase contrast MR: Analysis and correctionMagnetic Resonance in Medicine, 1998
- Isotropic diffusion‐weighted and spiral‐navigated interleaved EPI for routine imaging of acute strokeMagnetic Resonance in Medicine, 1997
- Optimized isotropic diffusion weightingMagnetic Resonance in Medicine, 1995
- Diffusion Weighting by the Trace of the Diffusion Tensor within a Single ScanMagnetic Resonance in Medicine, 1995