    Concomitant Gradient Effects Across Field Strengths and Gradient Amplitudes: Improved Estimation of Errors and Correction of Concomitant Dephasing and Diffusion Weighting

    by Viktor Olsson, Felix Mortensen, Emil Ljungberg, Frederik Testud, Ronnie Wirestam, Malwina Molendowska, Filip Szczepankiewicz

    Purpose: Deleterious effects from concomitant gradients are amplified at lower field strengths and stronger gradients. We aimed to show the signal errors caused by concomitant gradients across a wide range of hardware configurations and propose corrections that can be applied during experimental design and analysis. Theory and Methods: We derived a compact but accurate expression for concomitant gradients and simulated the associated signal bias across field strengths (0.03‐7 T) and gradient amplitudes (20‐600 mT/m) for asymmetric Maxwell‐compensated diffusion encoding gradient waveforms. Bias was assigned to “concomitant dephasing” or “concomitant diffusion weighting.” Concomitant dephasing was reduced by waveform correction that was deployed in the design stage. Concomitant diffusion weighting could be accounted for by using the actual gradient waveform during analysis. Results: Concomitant dephasing was caused by loss of Maxwell compensation during waveform resampling, with signal errors up to 100%, especially at low B 0 and high g max . Our waveform correction yielded a categorical improvement to signal accuracy, reducing bias to < 1% for most systems. However, bias at extreme B 0 ‐ g max ‐combinations remained > 1% (e.g., B 0 = 3 T and g max = 600 mT/m). Concomitant diffusion weighting caused biases above 1% at across all simulated MRI systems. Conclusion: Concomitant gradients have a relevant impact on signal accuracy, especially at low fields and ultra‐strong gradients. Concomitant dephasing must be considered for asymmetric waveforms, but can be largely suppressed by our correction method. Concomitant diffusion weighting is always present, regardless of waveform symmetry, but has a smaller impact and can be accounted for in the analysis.


  • Open Access

    Intraoperative 3D quantitative magnetic resonance imaging in paediatric brain tumour surgery

    by Per Nyman, Rafael Turczynski Holmgren, Emma Nordh, Anna Ljusberg, Oscar Snödahl, Frederik Testud, Ida Blystad, Peter Lundberg, Anders Tisell

    Purpose: • To investigate if R 1 and R 2 can reliably be measured using 3D quantitative MRI in an intraoperative setting when paediatric brain tumour surgery is performed. • To determine whether B 1 + inhomogeneities affect R 1 and R 2 measurements in normal-appearing white matter and the thalamus, respectively, and how R 1 and R 2 measurements are affected by different coils. • To assess how the relaxation parameters of brain tissue are affected by the intraoperative setting. Methods: The accuracy of R 1 and R 2 , the effect of B 1 + -field inhomogeneity and how the flex coil position affected R 1 and R 2 were evaluated, both pre- and intraoperatively during surgery. Ten patients were recruited, six girls and four boys aged 2–15 years, with varying tumour entities, all referred to surgery with intraoperative MR. The patients were scanned using a head coil preoperatively and flex coils intraoperatively. Control experiments were performed on phantoms in various positions, equivalent to the patient positions. ROIs (Regions of Interest) were positioned in areas representing normal-appearing matter. Relaxation rates R 1 and R 2 were calculated from 3D-quantification using an interleaved Look-Locker acquisition sequence with T 2 preparation pulse (3D-QALAS) data. Results: There was a significant increase of R 2 in the intraoperative setting compared to the preoperative 3D-QALAS measurements. In contrast to the patient examinations, control experiments using relaxation phantoms did not demonstrate similar differences. Conclusion: Relaxometry is feasible in the intraoperative setting. The detected differences between the quantitative R 2 values in tissue pre- and intraoperatively seem to be explained by the physiological conditions characterising the surgical situation.

  • Open Access

    Intraoperative 3D quantitative magnetic resonance imaging in paediatric brain tumour surgery

    by Per Nyman, Rafael Holmgren Turczynski, Emma Nordh, Anna Ljusberg, Oscar Snödahl, Frederik Testud, Ida Blystad, Peter Lundberg, Anders Tisell

    Purpose: To investigate if R 1 and R 2 can reliably be measured using 3D quantitative MRI in an intraoperative setting when paediatric brain tumour surgery is performed. To determine whether B 1+ inhomogeneities affect R 1 and R 2 measurements in normal-appearing white matter and the thalamus, respectively, and how R 1 and R 2 measurements are affected by different coils. To assess how the relaxation parameters of brain tissue are affected by the intraoperative setting. Methods: The accuracy of R 1 and R 2 , the effect of B 1+ -field inhomogeneity and how the flex coil position affected R 1 and R 2 were evaluated, both pre- and intraoperatively during surgery. Ten patients were recruited, six girls and four boys aged 2-15 years, with varying tumour entities, all referred to surgery with intraoperative MR. The patients were scanned using a head coil preoperatively and flex coils intraoperatively. Control experiments were performed on phantoms in various positions, equivalent to the patient positions. ROIs (Regions of Interest) were positioned in areas representing normal-appearing matter. Relaxation rates R 1 and R 2 were calculated from 3D-quantification using an interleaved Look-Locker acquisition sequence with T 2 preparation pulse (3D-QALAS) data. Results: There was a significant increase of R 2 in the intraoperative setting compared to the preoperative 3D-QALAS measurements. In contrast to the patient examinations, control experiments using relaxation phantoms did not demonstrate similar differences. Conclusion: Relaxometry is feasible in the intraoperative setting. The detected differences between the quantitative R 2 tissue values pre- and intraoperatively seem to be explained by the physiological conditions characterising the surgical situation.

  • Open Access

    A numerical human brain phantom for dynamic glucose‐enhanced (DGE) MRI: On the influence of head motion at 3T

    by Patrick M. Lehmann, Anina Seidemo, Mads Andersen, Xiang Xu, Xu Li, Nirbhay N. Yadav, Ronnie Wirestam, Patrick Liebig, Frederik Testud, Pia Sundgren, et al.

    Purpose: Dynamic glucose‐enhanced (DGE) MRI relates to a group of exchange‐based MRI techniques where the uptake of glucose analogues is studied dynamically. However, motion artifacts can be mistaken for true DGE effects, while motion correction may alter true signal effects. The aim was to design a numerical human brain phantom to simulate a realistic DGE MRI protocol at 3T that can be used to assess the influence of head movement on the signal before and after retrospective motion correction.Methods: MPRAGE data from a tumor patient were used to simulate dynamic Z‐spectra under the influence of motion. The DGE responses for different tissue types were simulated, creating a ground truth. Rigid head movement patterns were applied as well as physiological dilatation and pulsation of the lateral ventricles and head‐motion‐induced B0‐changes in presence of first‐order shimming. The effect of retrospective motion correction was evaluated.Results: Motion artifacts similar to those previously reported for in vivo DGE data could be reproduced. Head movement of 1 mm translation and 1.5 degrees rotation led to a pseudo‐DGE effect on the order of 1% signal change. B0 effects due to head motion altered DGE changes due to a shift in the water saturation spectrum. Pseudo DGE effects were partly reduced or enhanced by rigid motion correction depending on tissue location.Conclusion: DGE MRI studies can be corrupted by motion artifacts. Designing post‐processing methods using retrospective motion correction including B0 correction will be crucial for clinical implementation. The proposed phantom should be useful for evaluation and optimization of such techniques.


  • Open Access

    Fetal 3D cardiovascular cine image acquisition using radial sampling and compressed sensing

    by Marjolein Piek, Daniel Ryd, Johannes Töger, Frederik Testud, Erik Hedström, Anthony H. Aletras

    Purpose: To explore a fetal 3D cardiovascular cine acquisition using a radial image acquisition and compressed‐sensing reconstruction and compare image quality and scan time with conventional multislice 2D imaging.Methods: Volumetric fetal cardiac data were acquired in 26 volunteers using a radial 3D balanced SSFP pulse sequence. Cardiac gating was performed using a Doppler ultrasound device. Images were reconstructed using a parallel‐imaging and compressed‐sensing algorithm. Multiplanar reformatting to standard cardiac views was performed before image analysis. Clinical 2D images were used for comparison. Qualitative and quantitative image evaluation were performed by two experienced observers (scale: 1–4). Volumes, mass, and function were assessed.Results: Average scan time for the 3D imaging was 6 min, including one localizer. A 2D imaging stack covering the entire heart including localizer sequences took at least 6.5 min, depending on planning complexity. The 3D acquisition was successful in 7 of 26 subjects (27%). Overall image contrast and perceived resolution were lower in the 3D images. Nonetheless, the 3D images had, on average, a moderate cardiac diagnostic quality (median [range]: 3 [1–4]). Standard clinical 2D acquisitions had a high cardiac diagnostic quality (median [range]: 4 [3, 4]). Cardiac measurements were not different between 2D and 3D images (allp > 0.16).Conclusion: The presented free‐breathing whole‐heart fetal 3D radial cine MRI acquisition and reconstruction method enables retrospective visualization of all cardiac views while keeping examination times short. This proof‐of‐concept work produced images with diagnostic quality, while at the same time reducing the planning complexity to a single localizer.


  • Open Access

    Validation and reproducibility of cardiovascular 4D-flow MRI from two vendors using 2 × 2 parallel imaging acceleration in pulsatile flow phantom and in vivo with and without respiratory gating

    by Jelena Bock, Johannes Töger, Sebastian Bidhult, Karin Markenroth Bloch, Per Arvidsson, Mikael Kanski, Håkan Arheden, Frederik Testud, Andreas Greiser, Einar Heiberg, et al.

    4D-flow magnetic resonance imaging (MRI) is increasingly used. To validate 4D-flow sequences in phantom and in vivo, comparing volume flow and kinetic energy (KE) head-to-head, with and without respiratory gating. Achieva dStream (Philips Healthcare) and MAGNETOM Aera (Siemens Healthcare) 1.5-T scanners were used. Phantom validation measured pulsatile, three-dimensional flow with 4D-flow MRI and laser particle imaging velocimetry (PIV) as reference standard. Ten healthy participants underwent three cardiac MRI examinations each, consisting of cine-imaging, 2D-flow (aorta, pulmonary artery), and 2 × 2 accelerated 4D-flow with (Resp+) and without (Resp−) respiratory gating. Examinations were acquired consecutively on both scanners and one examination repeated within two weeks. Volume flow in the great vessels was compared between 2D- and 4D-flow. KE were calculated for all time phases and voxels in the left ventricle. Phantom results showed high accuracy and precision for both scanners. In vivo, higher accuracy and precision (P < 0.001) was found for volume flow for the Aera prototype with Resp+ (–3.7 ± 10.4 mL, r = 0.89) compared to the Achieva product sequence (–17.8 ± 18.6 mL, r = 0.56). 4D-flow Resp− on Aera had somewhat larger bias (–9.3 ± 9.6 mL, r = 0.90) compared to Resp+ (P = 0.005). KE measurements showed larger differences between scanners on the same day compared to the same scanner at different days. Sequence-specific in vivo validation of 4D-flow is needed before clinical use. 4D-flow with the Aera prototype sequence with a clinically acceptable acquisition time (<10 min) showed acceptable bias in healthy controls to be considered for clinical use. Intra-individual KE comparisons should use the same sequence.


  • Open Access

    Single-shot imaging with higher-dimensional encoding using magnetic field monitoring and concomitant field correction

    by Frederik Testud, Daniel Gallichan, Kelvin J. Layton, Christoph Barmet, Anna M. Welz, Andrew Dewdney, Chris A. Cocosco, Klaas P. Pruessmann, Jürgen Hennig, Maxim Zaitsev

    Purpose PatLoc (Parallel Imaging Technique using Localized Gradients) accelerates imaging and introduces a resolution variation across the field-of-view. Higher-dimensional encoding employs more spatial encoding magnetic fields (SEMs) than the corresponding image dimensionality requires, e.g. by applying two quadratic and two linear spatial encoding magnetic fields to reconstruct a 2D image. Images acquired with higher-dimensional single-shot trajectories can exhibit strong artifacts and geometric distortions. In this work, the source of these artifacts is analyzed and a reliable correction strategy is derived. Methods A dynamic field camera was built for encoding field calibration. Concomitant fields of linear and nonlinear spatial encoding magnetic fields were analyzed. A combined basis consisting of spherical harmonics and concomitant terms was proposed and used for encoding field calibration and image reconstruction. Results A good agreement between the analytical solution for the concomitant fields and the magnetic field simulations of the custom-built PatLoc SEM coil was observed. Substantial image quality improvements were obtained using a dynamic field camera for encoding field calibration combined with the proposed combined basis. Conclusion The importance of trajectory calibration for single-shot higher-dimensional encoding is demonstrated using the combined basis including spherical harmonics and concomitant terms, which treats the concomitant fields as an integral part of the encoding. Magn Reson Med 73:1340–1357, 2015.


  • Direct Magnetic Field Estimation Based on Echo Planar Raw Data

    by Frederik Testud, Daniel Nicolas Splitthoff, Oliver Speck, Jürgen Hennig, Maxim Zaitsev

    Gradient recalled echo echo planar imaging is widely used in functional magnetic resonance imaging. The fast data acquisition is, however, very sensitive to field inhomogeneities which manifest themselves as artifacts in the images. Typically used correction methods have the common deficit that the data for the correction are acquired only once at the beginning of the experiment, assuming the field inhomogeneity distribution ΔB 0 does not change over the course of the experiment. In this paper, methods to extract the magnetic field distribution from the acquired k-space data or from the reconstructed phase image of a gradient echo planar sequence are compared and extended. A common derivation for the presented approaches provides a solid theoretical basis, enables a fair comparison and demonstrates the equivalence of the k-space and the image phase based approaches. The image phase analysis is extended here to calculate the local gradient in the readout direction and improvements are introduced to the echo shift analysis, referred to here as "k-space filtering analysis." The described methods are compared to experimentally acquired ΔB 0 maps in phantoms and in vivo. The k-space filtering analysis presented in this work demonstrated to be the most sensitive method to detect field inhomogeneities.