Abstract
Repeated rib elements are used as roughness medium to increase heat transfer. An experimental and numerical analysis has been performed to study the influence of number of gaps on absorber plates pasted with arc shaped roughness elements with gaps to study the heat transfer (Nu) and friction factor (f) used in solar air-heaters (SAHs). ANSYS was used to simulate the air flow through a rectangular passage. A heating source of 1000 W/m2 was provided on the top of the surface to simulate the radiant energy of the sun. Twenty seven combinations of roughened duct were investigated using the software as well as on an experimental setup. The result shows that the highest value of Nu was obtained for roughness element which is having number of gaps equal to 2. Thermo-hydraulic efficiency parameter has also been evaluated for the same.

This publication has 31 references indexed in Scilit: