Navneet Kumar Pandey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Navneet Kumar Pandey has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Abhishek Sharma
G L Bajaj Institute of Technology and Management
2 shared publications V. K. Bajpai
2 shared publications- V. K. Bajpai
N.I.T Kurukshetra
2 shared publications Varun
National Institute of Technology Hamirpur, HP 177005, India
2 shared publications- Abhishek Sharma
Department of Mechanical Engineering, Government Engineering College Palamu (Department of Higher and Technical Education, Govt. of Jharkhand), Medininagar, India
1 shared publication Anil Prakash Singh
Inderprashtha Engineering College, Ghaziabad, India
1 shared publication
Latest Publications
- 14 October 2022
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 44 (1) , 413-423
Fluid flow and heat transfer evaluation and optimisation of solar-assisted air-heater having multi-arcs with gaps used as roughness elements
Solar air heaters are used for various drying and room heating purpose. Techniques have been developed to increase its effectiveness by various methods, the most common being the introduction of roughness elements on the underside of the absorber plate.The current study a combined approach of response surface methodology and experimental findings has been done to investigate using various dimensionless parameters on the thermo-hydraulic performance parameters of solar air heaters with multi-arc shaped roughness elements with gaps on the absorber plate. RSM modelling was carried out with objective functions as maximization of Nusselt number and minimization of Friction factor. Optimized calculated values of design parameters for THPP of SAH to provide maximum Nusselt number were estimated as Reynolds Number = 21000, e/D = 0.0443, d/x = 0.25 and g/e = 1.7323. The enhancement ratio of Friction factor and Nusselt number were found to be 2.101 and 3.53 respectively.
- 14 October 2022
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 44 (1) , 413-423
Fluid flow and heat transfer evaluation and optimisation of solar-assisted air-heater having multi-arcs with gaps used as roughness elements
Solar air heaters are used for various drying and room heating purpose. Techniques have been developed to increase its effectiveness by various methods, the most common being the introduction of roughness elements on the underside of the absorber plate.The current study a combined approach of response surface methodology and experimental findings has been done to investigate using various dimensionless parameters on the thermo-hydraulic performance parameters of solar air heaters with multi-arc shaped roughness elements with gaps on the absorber plate. RSM modelling was carried out with objective functions as maximization of Nusselt number and minimization of Friction factor. Optimized calculated values of design parameters for THPP of SAH to provide maximum Nusselt number were estimated as Reynolds Number = 21000, e/D = 0.0443, d/x = 0.25 and g/e = 1.7323. The enhancement ratio of Friction factor and Nusselt number were found to be 2.101 and 3.53 respectively.
- 25 January 2021
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 4129-4137
Exergy analysis of roughened duct using multiple arcs with gaps used in solar air heaters
Energy from the sun can either be stored (as electricity, using solar panels) or used as a heat source to do some work (solar heating and dying applications). Solar Air Heaters (SAH) come in the second category. The absorber plate roughened with artificial ribs is found to have better thermal ability in comparison to smooth duct SAH. It is also established that creation of artificial roughness leads to increased friction penalty. Exergy analysis is a useful tool for the design of SAH’s as it methodically calculates the quality of useful energy and its friction penalty. Exergetic efficiency of a SAH with multi-arc elements with discrete gaps is studied mathematically and the results obtained are found to be impressive as compared to smooth SAH. The results have also been validated experimentally and are found to be in accordance with the mathematical results. The study includes the effect of various roughness parameters on exergetic efficiency. Results indicated temperature rise parameter values between 0.003 and 0.012 as optimum. A relative roughness pitch of 8, relative roughness width of 5, relative gap position of 0.65, arc angle of 60°, relative gap width of 1.0 and relative roughness height of 0.045 are found to yield maximum exergetic efficiency values for the studied range of temperature rise parameter.
- 25 January 2021
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 4129-4137
Exergy analysis of roughened duct using multiple arcs with gaps used in solar air heaters
Energy from the sun can either be stored (as electricity, using solar panels) or used as a heat source to do some work (solar heating and dying applications). Solar Air Heaters (SAH) come in the second category. The absorber plate roughened with artificial ribs is found to have better thermal ability in comparison to smooth duct SAH. It is also established that creation of artificial roughness leads to increased friction penalty. Exergy analysis is a useful tool for the design of SAH’s as it methodically calculates the quality of useful energy and its friction penalty. Exergetic efficiency of a SAH with multi-arc elements with discrete gaps is studied mathematically and the results obtained are found to be impressive as compared to smooth SAH. The results have also been validated experimentally and are found to be in accordance with the mathematical results. The study includes the effect of various roughness parameters on exergetic efficiency. Results indicated temperature rise parameter values between 0.003 and 0.012 as optimum. A relative roughness pitch of 8, relative roughness width of 5, relative gap position of 0.65, arc angle of 60°, relative gap width of 1.0 and relative roughness height of 0.045 are found to yield maximum exergetic efficiency values for the studied range of temperature rise parameter.
- 28 September 2020
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 3275-3281
CFD and thermo-hydraulic analysis of multiple arc roughened absorber plate with gaps used in solar air heaters
Repeated rib elements are used as roughness medium to increase heat transfer. An experimental and numerical analysis has been performed to study the influence of number of gaps on absorber plates pasted with arc shaped roughness elements with gaps to study the heat transfer (Nu) and friction factor (f) used in solar air-heaters (SAHs). ANSYS was used to simulate the air flow through a rectangular passage. A heating source of 1000 W/m2 was provided on the top of the surface to simulate the radiant energy of the sun. Twenty seven combinations of roughened duct were investigated using the software as well as on an experimental setup. The result shows that the highest value of Nu was obtained for roughness element which is having number of gaps equal to 2. Thermo-hydraulic efficiency parameter has also been evaluated for the same.
- 28 September 2020
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 3275-3281
CFD and thermo-hydraulic analysis of multiple arc roughened absorber plate with gaps used in solar air heaters
Repeated rib elements are used as roughness medium to increase heat transfer. An experimental and numerical analysis has been performed to study the influence of number of gaps on absorber plates pasted with arc shaped roughness elements with gaps to study the heat transfer (Nu) and friction factor (f) used in solar air-heaters (SAHs). ANSYS was used to simulate the air flow through a rectangular passage. A heating source of 1000 W/m2 was provided on the top of the surface to simulate the radiant energy of the sun. Twenty seven combinations of roughened duct were investigated using the software as well as on an experimental setup. The result shows that the highest value of Nu was obtained for roughness element which is having number of gaps equal to 2. Thermo-hydraulic efficiency parameter has also been evaluated for the same.
- 4 November 2016
- Published by African Journals Online (AJOL) in International Journal of Engineering, Science and Technology
- Vol. 8 (1) , 34-42
Thermo-hydraulic performance enhancement of solar air heater (SAH) having multiple arcs with gap shaped roughness element on absorber plate
The present paper studies the thermal performance of solar air heater which is artificially roughened by providing multiple arcs with gap shaped roughness element. As thermal efficiency of smooth collector is quite low, hence there is a need to augment heat transfer from the absorbing surface. The experimentation has been carried out for Reynolds number (Re) ranges from 2100- 21000, relative roughness height (e/D) of 0.044, relative roughness pitch (p/e) of 8, relative gap distance (d/x) range of 0.25- 0.85, relative roughness width (W/w) ranges from 1-7, relative gap width (g/e) range of 0.5-2 and arc angle (a) of 60°. The thermal efficiency is found to be best for relative gap distance (d/x), relative gap width (g/e) and relative roughness width (W/w) values are 0.65, 1.0 and 5 respectively.Keywords: Solar air heater; Nusselt number; thermal efficiency; multiple arcs with gap; roughened
- 4 November 2016
- Published by African Journals Online (AJOL) in International Journal of Engineering, Science and Technology
- Vol. 8 (1) , 34-42
Thermo-hydraulic performance enhancement of solar air heater (SAH) having multiple arcs with gap shaped roughness element on absorber plate
The present paper studies the thermal performance of solar air heater which is artificially roughened by providing multiple arcs with gap shaped roughness element. As thermal efficiency of smooth collector is quite low, hence there is a need to augment heat transfer from the absorbing surface. The experimentation has been carried out for Reynolds number (Re) ranges from 2100- 21000, relative roughness height (e/D) of 0.044, relative roughness pitch (p/e) of 8, relative gap distance (d/x) range of 0.25- 0.85, relative roughness width (W/w) ranges from 1-7, relative gap width (g/e) range of 0.5-2 and arc angle (a) of 60°. The thermal efficiency is found to be best for relative gap distance (d/x), relative gap width (g/e) and relative roughness width (W/w) values are 0.65, 1.0 and 5 respectively.Keywords: Solar air heater; Nusselt number; thermal efficiency; multiple arcs with gap; roughened
- 1 September 2016
- Published by Elsevier in Solar Energy
- Vol. 134, 314-326
Experimental investigation of heat transfer augmentation using multiple arcs with gap on absorber plate of solar air heater
- 1 September 2016
- Published by Elsevier in Solar Energy
- Vol. 134, 314-326
Experimental investigation of heat transfer augmentation using multiple arcs with gap on absorber plate of solar air heater
- 11 May 2016
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 41 (11) , 4517-4530
Heat Transfer and Friction Factor Study of a Solar Air Heater Having Multiple Arcs with Gap-Shaped Roughness Element on Absorber Plate
- 11 May 2016
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 41 (11) , 4517-4530
Heat Transfer and Friction Factor Study of a Solar Air Heater Having Multiple Arcs with Gap-Shaped Roughness Element on Absorber Plate
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10636927,p. 462-473
Minimizing the Communication Cost of Aggregation in Publish/Subscribe Systems
Modern applications for distributed publish/subscribe systems often require stream aggregation capabilities along with rich data filtering. When compared to other distributed systems, aggregation in pub/sub differentiates itself as a complex problem which involves dynamic dissemination paths that are difficult to predict and optimize for a priori, temporal fluctuations in publication rates, and the mixed presence of aggregated and non-aggregated workloads. In this paper, we propose a formalization for the problem of minimizing communication traffic in the context of aggregation in pub/sub. We present a solution to this minimization problem by using a reduction to the well-known problem of minimum vertex cover in a bipartite graph. This solution is optimal under the strong assumption of complete knowledge of future publications. We call the resulting algorithm "Aggregation Decision, Optimal with Complete Knowledge" (ADOCK). We also show that under a dynamic setting without full knowledge, ADOCK can still be applied to produce a low, yet not necessarily optimal, communication cost. We also devise a computationally cheaper dynamic approach called "Aggregation Decision with Weighted Publication" (WAD). We compare our solutions experimentally using two real datasets and explore the trade-offs with respect to communication and computation costs.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10636927,p. 462-473
Minimizing the Communication Cost of Aggregation in Publish/Subscribe Systems
Modern applications for distributed publish/subscribe systems often require stream aggregation capabilities along with rich data filtering. When compared to other distributed systems, aggregation in pub/sub differentiates itself as a complex problem which involves dynamic dissemination paths that are difficult to predict and optimize for a priori, temporal fluctuations in publication rates, and the mixed presence of aggregated and non-aggregated workloads. In this paper, we propose a formalization for the problem of minimizing communication traffic in the context of aggregation in pub/sub. We present a solution to this minimization problem by using a reduction to the well-known problem of minimum vertex cover in a bipartite graph. This solution is optimal under the strong assumption of complete knowledge of future publications. We call the resulting algorithm "Aggregation Decision, Optimal with Complete Knowledge" (ADOCK). We also show that under a dynamic setting without full knowledge, ADOCK can still be applied to produce a low, yet not necessarily optimal, communication cost. We also devise a computationally cheaper dynamic approach called "Aggregation Decision with Weighted Publication" (WAD). We compare our solutions experimentally using two real datasets and explore the trade-offs with respect to communication and computation costs.