Clinical application of deep learning-based synthetic CT from real MRI to improve dose planning accuracy in Gamma Knife radiosurgery: a proof of concept study
- 13 June 2022
- journal article
- research article
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 12 (4) , 359-367
Abstract
Dose planning for Gamma Knife radiosurgery (GKRS) uses the magnetic resonance (MR)-based tissue maximum ratio (TMR) algorithm, which calculates radiation dose without considering heterogeneous radiation attenuation in the tissue. In order to plan the dose considering the radiation attenuation, the Convolution algorithm should be used, and additional radiation exposure for computed tomography (CT) and registration errors between MR and CT are entailed. This study investigated the clinical feasibility of synthetic CT (sCT) from GKRS planning MR using deep learning. The model was trained using frame-based contrast-enhanced T1-weighted MR images and corresponding CT slices from 54 training subjects acquired for GKRS planning. The model was applied prospectively to 60 lesions in 43 patients including benign tumor such as meningioma and pituitary adenoma, metastatic brain tumors, and vascular disease of various location for evaluating the model and its application. We evaluated the sCT and compared between treatment plans made with MR only (TMR 10 plan), MR and real CT (rCT; Convolution with rCT [Conv-rCT] plan), and MR and synthetic CT (Convolution with sCT [Conv-sCT] plan). The mean absolute error (MAE) of 43 sCT was 107.35 ± 16.47 Hounsfield units. The TMR 10 treatment plan differed significantly from plans made by Conv-sCT and Conv-rCT. However, the Conv-sCT and Conv-rCT plans were similar. This study showed the practical applicability of deep learning based on sCT in GKRS. Our results support the possibility of formulating GKRS treatment plans while considering radiation attenuation in the tissue using GKRS planning MR and no radiation exposure.Keywords
Funding Information
- Korea Health Industry Development Institute (HI21C1161)
- Korea Medical Device Development Fund (202011D25)
- Severance Hospital Research fund for Clinical Excellence
This publication has 27 references indexed in Scilit:
- MR-based synthetic CT generation using a deep convolutional neural network methodMedical Physics, 2017
- Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Gamma Knife radiosurgery with CT image‐based dose calculationJournal of Applied Clinical Medical Physics, 2015
- Patch‐based generation of a pseudo CT from conventional MRI sequences for MRI‐only radiotherapy of the brainMedical Physics, 2015
- A unifying probabilistic Bayesian approach to derive electron density from MRI for radiation therapy treatment planningPhysics in Medicine & Biology, 2014
- Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiation therapyPhysics in Medicine & Biology, 2013
- The Design of SimpleITKFrontiers in Neuroinformatics, 2013
- Results of a Multi-Institutional Benchmark Test for Cranial CT/MR Image RegistrationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Scattered data interpolation with multilevel B-splinesIEEE Transactions on Visualization and Computer Graphics, 1997
- Image metamorphosis with scattered feature constraintsIEEE Transactions on Visualization and Computer Graphics, 1996