Endovascular Closure of Chronic Dissection Entries in the Aortic Arch Using the Amplatzer Vascular Plug II as a Sealing Button
- 12 February 2016
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 23 (2) , 378-383
Abstract
Purpose: To present a new endovascular technique to avoid open surgical arch reconstruction in selected patients with aneurysmal dilatation due to small chronic dissection entries in the aortic arch. Technique: The true and the false lumen of the aortic arch are catheterized from the femoral arteries. An Amplatzer Vascular Plug II (AVP II) is advanced through the proximal entry from the false lumen side and deployed as a sealing button in the entry hole, with 1 disc in the true lumen and the remaining 2 discs in the false lumen. This technique was used in 4 patients with chronic dissection involving the aortic arch, three of whom had had previous surgery for acute type A aortic dissection. In 3 patients, the false lumen of the thoracic aorta was successfully obliterated, with thrombosis and aortic diameter reduction during follow-up. In 1 patient, false lumen flow persisted, and he was subsequently treated with a total arch reconstruction and frozen elephant trunk. Conclusion: Endovascular closure of small proximal dissection entries in the aortic arch with an AVP II used as a sealing button is feasible and may be an alternative to open surgical arch reconstruction in selected patients with chronic aortic dissection and secondary aneurysm expansion.Keywords
This publication has 13 references indexed in Scilit:
- Embolization of Persistent False Lumen Through Reentry Tear in a Patient Who Underwent Hemiarch Replacement Operation Due to Type A DissectionThe Annals of Thoracic Surgery, 2015
- Reoperation for enlargement of the distal aorta after initial surgery for acute type A aortic dissectionThe Journal of Thoracic and Cardiovascular Surgery, 2015
- Outcomes after false lumen embolization with covered stent devices in chronic dissectionJournal of Vascular Surgery, 2014
- Global experience with an inner branched arch endograftThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Addressing Persistent False Lumen Flow in Chronic Aortic Dissection: The Knickerbocker TechniqueJournal of Endovascular Therapy, 2014
- Distal False Lumen Occlusion in Aortic Dissection With a Homemade Extra-Large Vascular Plug: The Candy-Plug TechniqueJournal of Endovascular Therapy, 2013
- The Amplatzer Vascular Plug: A Review of the Device and its Clinical ApplicationsCardioVascular and Interventional Radiology, 2012
- The fate of the distal aorta after repair of acute type A aortic dissectionThe Journal of Thoracic and Cardiovascular Surgery, 2007
- The Elephant Trunk Technique for Staged Repair of Complex Aneurysms of the Entire Thoracic AortaThe Annals of Thoracic Surgery, 2006
- Endovascular Stent–Graft Placement for the Treatment of Acute Aortic DissectionNew England Journal of Medicine, 1999