MFMårten Falkenberg

Mårten Falkenberg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mårten Falkenberg has a total of 63 co-authors. Here are the top co-authors by number of shared publications:

  • Håkan Roos

    Department of Hybrid and Interventional Surgery, Unit of Vascular Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden

    2 shared publications
  • Joakim Nordanstig

    Department of Molecular and Clinical Medicine, Institute of Medicine, University of Gothenburg, Gothenburg, Sweden; Department of Vascular Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden

    2 shared publications
  • Olof Henrikson

    Department of Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden

    2 shared publications
  • Per Skoog

    Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden

    2 shared publications
  • Alois Regensburger

    Siemens Healthcare GmbH, Forchheim, Germany

    1 shared publication
  • Anders Jeppsson

    Department of Thoracic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden

    1 shared publication

Latest Publications

  • Top Cited Papers

    Paclitaxel-coated versus uncoated devices for infrainguinal endovascular revascularisation in chronic limb-threatening ischaemia (SWEDEPAD 1): a multicentre, participant-masked, registry-based, randomised controlled trial

    by Mårten Falkenberg, Stefan James, Manne Andersson, Mattias Andersson, Martin Delle, Jan Engström, Torbjörn Fransson, Peter Gillgren, Anna Hilbertson, Tal M Hörer, et al.


  • Open Access

    Radiopaque Fiducials Guiding Laparoscopic Resection of Liver Tumors

    by Mårten Falkenberg, Magnus Rizell, Malin Sternby Eilard, Alois Regensburger, Roya Bs Razazzian, Niclas Kvarnström

    Background: Minimal invasive laparoscopic resection of liver tumors is less traumatic compared with open surgical resection and may be a better option for many patients. However, localization of intrahepatic tumors remains a challenge. Availability of hybrid operating rooms, equipped for high performance radiologic imaging, allows for new methods of surgical navigation. Methods: Twelve patients planned for laparoscopic resection of liver tumors were included. Before resection started, tumors were marked with radiopaque fiducials. Four fiducials were positioned with ultrasound within 1 cm of the tumor. Tumor and fiducials were localized with contrast enhanced cone beam computed tomography. Fluoroscopy with an overlay of cone beam computed tomography markings was projected side-by-side on the same screen as the laparoscopic view to visualize tumor location. The fiducials were eventually removed. Laparoscopic ultrasound, the standard method of localizing a tumor, was also used. The benefits of the 2 visualization methods were estimated by the operator. Procedure times, radiation doses and resection margins were recorded. Results: Fluoroscopy with radiopaque fiducials provided valuable information, complementing the laparoscopic ultrasound, particularly during the early phase of resection. In the later phase, mobilization of the tumor-containing liver segment caused significant displacement of the fluoroscopic overlay. The technique evolved during course of the study, with decreasing procedure times and radiation doses. Radical resection was achieved for all patients. Conclusions: Radiopaque fiducials and fluoroscopy can complement laparoscopic ultrasound for guiding resection of liver tumors. Combining radiologic and optical imaging in a hybrid operating suit may facilitate development of augmented reality techniques for surgical navigation.


  • Open Access

    A Reperfusion BOLD-MRI Tissue Perfusion Protocol Reliably Differentiate Patients with Peripheral Arterial Occlusive Disease from Healthy Controls

    by Kristina Törngren, Stefanie Eriksson, Jonathan Arvidsson, Mårten Falkenberg, Åse A. Johnsson, Carl Sjöberg, Kerstin Lagerstrand, Joakim Nordanstig

    There is no established technique that directly quantifies lower limb tissue perfusion. Blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI) is an MRI technique that can determine skeletal muscle perfusion. BOLD-MRI relies on magnetic differences of oxygenated and deoxygenated hemoglobin, and regional changes in oxy/deoxyhemoglobin ratio can be recorded by T2* weighted MRI sequences. We aimed to test whether BOLD-MRI can differentiate lower limb tissue perfusion in peripheral arterial occlusive disease (PAOD) patients and healthy controls. Twenty-two PAOD patients and ten healthy elderly volunteers underwent lower limb BOLD-MRI. Reactive hyperemia was provoked by transient cuff compression and images of the gastrocnemius and soleus muscles were continuously acquired at rest, during ischemia and reperfusion. Key BOLD parameters were baseline T2* absolute value and time to T2* peak value after cuff deflation (TTP). Correlations between imaging parameters and ankle-brachial index (ABI) was investigated. The mean TTP was considerably prolonged in PAOD patients compared to healthy controls (m. gastrocnemius: 111 ± 46 versus 48 ± 22 s, p = 0.000253; m. soleus: 100 ± 42 versus 41 ± 30 s, p = 0.000216). Both gastrocnemius and soleus TTP values correlated strongly with ABI (−0.82 and −0.78, p < 0.01). BOLD-MRI during reactive hyperemia differentiated most PAOD patients from healthy controls. TTP was the most decisive parameter and strongly correlated with the ABI.


  • Open Access

    Comparison of Magnetic Resonance Angiography and Digital Subtraction Angiography for the Assessment of Infrapopliteal Arterial Occlusive Lesions, Based on the TASC II Classification Criteria

    by Erik Baubeta Fridh, Karin Ludwigs, Angelica Svalkvist, Manne Andersson, Joakim Nordanstig, Mårten Falkenberg, Åse A. Johnsson

    This paper aimed to study the agreement and repeatability, both intra- and interobserver, of infrapopliteal lesion assessment with magnetic resonance angiography (MRA), using the TransAtlantic Inter-Society Consensus (TASC) II criteria, with perioperative digital subtraction angiography (DSA) as a reference. Sixty-eight patients with an MRA preceding an endovascular infrapopliteal revascularization were included. Preoperative MRAs and perioperative DSAs were evaluated in random order by three independent observers using the TASC II classification. The results were analyzed using visual grading characteristics (VGC) analysis and Krippendorff’s α. No systematic difference was found between modalities: area under the VGC curve (AUCVGC) = 0.48 (p = 0.58) or intraobserver; AUCVGC for Observer 1 and 2 respectively, 0.49 (p = 0.85) and 0.53 (p = 0.52) for MRA compared with 0.54 (p = 0.30) and 0.49 (p = 0.81) for DSA. Interobserver differences were seen: AUCVGC of 0.63 (p < 0.01) for DSA and 0.80 (p < 0.01) for MRA. These results were confirmed using Krippendorff’s α for the three observers showing 0.13 (95% confidence interval (CI) −0.07–0.31) for MRA and 0.39 (95% CI 0.23–0.53) for DSA. Poor interobserver agreement was also found in the choice of a target vessel on preoperative MRA: Krippendorff’s α = 0.19 (95% CI 0.01‒0.36). In conclusion, infrapopliteal lesions can be reliably determined on preoperative MRA, but interobserver variability regarding the choice of a target vessel is a major concern that appears to affect the overall TASC II grade.


  • Open Access

    Performance of a feature-based algorithm for 3D-3D registration of CT angiography to cone-beam CT for endovascular repair of complex abdominal aortic aneurysms

    by Giasemi Koutouzi, Behrooz Nasihatkton, Monika Danielak-Nowak, Henrik Leonhardt, Mårten Falkenberg, Fredrik Kahl

    A crucial step in image fusion for intraoperative guidance during endovascular procedures is the registration of preoperative computed tomography angiography (CTA) with intraoperative Cone Beam CT (CBCT). Automatic tools for image registration facilitate the 3D image guidance workflow. However their performance is not always satisfactory. The aim of this study is to assess the accuracy of a new fully automatic, feature-based algorithm for 3D3D registration of CTA to CBCT. The feature-based algorithm was tested on clinical image datasets from 14 patients undergoing complex endovascular aortic repair. Deviations in Euclidian distances between vascular as well as bony landmarks were measured and compared to an intensity-based, normalized mutual information algorithm. The results for the feature-based algorithm showed that the median 3D registration error between the anatomical landmarks of CBCT and CT images was less than 3 mm. The feature-based algorithm showed significantly better accuracy compared to the intensity-based algorithm (p < 0.001). A feature-based algorithm for 3D image registration is presented.


  • Endovascular Closure of Chronic Dissection Entries in the Aortic Arch Using the Amplatzer Vascular Plug II as a Sealing Button

    by Mårten Falkenberg, Håkan Roos, Vincenzo Lepore, Gunnar Svensson, Karin Zachrisson, Olof Henrikson

    Purpose: To present a new endovascular technique to avoid open surgical arch reconstruction in selected patients with aneurysmal dilatation due to small chronic dissection entries in the aortic arch. Technique: The true and the false lumen of the aortic arch are catheterized from the femoral arteries. An Amplatzer Vascular Plug II (AVP II) is advanced through the proximal entry from the false lumen side and deployed as a sealing button in the entry hole, with 1 disc in the true lumen and the remaining 2 discs in the false lumen. This technique was used in 4 patients with chronic dissection involving the aortic arch, three of whom had had previous surgery for acute type A aortic dissection. In 3 patients, the false lumen of the thoracic aorta was successfully obliterated, with thrombosis and aortic diameter reduction during follow-up. In 1 patient, false lumen flow persisted, and he was subsequently treated with a total arch reconstruction and frozen elephant trunk. Conclusion: Endovascular closure of small proximal dissection entries in the aortic arch with an AVP II used as a sealing button is feasible and may be an alternative to open surgical arch reconstruction in selected patients with chronic aortic dissection and secondary aneurysm expansion.


  • Open Access

    Air bubbles are released by thoracic endograft deployment: An in vitro experimental study

    by Kamuran Inci, Giasemi Koutouzi, Valery Chernoray, Anders Jeppsson, Håkan Nilsson, Mårten Falkenberg

    Purpose: Embolic stroke is a dreaded complication of thoracic endovascular aortic repair. The prevailing theory about its cause is that particulate debris from atherosclerotic lesions in the aortic wall are dislodged by endovascular instruments and embolize to the brain. An alternative source of embolism might be air trapped in the endograft delivery system. The aim of this experimental study was to determine whether air is released during deployment of a thoracic endograft. Methods: In an experimental benchtop study, eight thoracic endografts (five Medtronic Valiant Thoracic and three Gore TAG) were deployed in a water-filled transparent container drained from air. Endografts were prepared and deployed according to their instructions for use. Deployment was filmed and the volume of air released was collected and measured in a calibrated syringe. Results: Air was released from all the endografts examined. Air volumes ranged from 0.1 to 0.3 mL for Medtronic Valiant Thoracic and from <0.025 to 0.04 mL for Gore TAG. The largest bubbles had a diameter of approximately 3 mm and came from the proximal end of the Medtronic Valiant device. Conclusion: Air bubbles are released from thoracic endografts during deployment. Air embolism may be an alternative cause of stroke during thoracic endovascular aortic repair.


  • Ethylene vinyl alcohol copolymer (Onyx) to seal type 1 endoleak. A new technique

    by Olof Henrikson, Håkan Roos, Mårten Falkenberg

    The aim of this study was to investigate whether the liquid embolic agent Onyx, an ethylene vinyl alcohol copolymer, can be used to seal type 1 endoleaks during endovascular aortic repair (EVAR). Six patients with large aortic aneurysms and remaining type 1 endoleaks during or after EVAR were treated with Onyx embolization through a microcatheter placed in the proximal neck in five cases and in the distal neck in one case. Four of the patients were treated using the chimney technique. The type 1 endoleak was primarily sealed by Onyx in all six patients. There was no distal embolization. Two patients had complications during follow-up. One patient had occlusions of chimney grafts to the renal arteries and to one leg extension. These occlusions were not anatomically related to Onyx embolization. One patient had late stentgraft migration of the Onyx-treated distal neck with aneurysm rupture 18 months after treatment. Early experience of Onyx embolization as a bailout solution of type 1 endoleaks after complicated EVAR is promising. However, effective seal with Onyx does not prevent late stentgraft migration. More reported patients and longer follow-up are necessary to evaluate this new technique.


    • 1 April 2010
      • Vol. 51  (2) , 177-82

    TEVAR and covering the celiac artery. Is it safe or not?

    by M Falkenberg, L Lönn, T Schroeder, M Delle

    Thoracic endovascular aortic repair (TEVAR) is the treatment of choice for descending thoracic aortic aneurysms (TAA). However, not all patients with TAA can be treated with the endovascular technique. Insufficient proximal and/or distal sealing zone is the most common reason for open surgery in these patients. If the distal sealing zone above the celiac axis is too short, several endovascular alternatives are possible; hybrid procedures with TEVAR and open by-pass to the celiac artery, custom made stent-grafts with scallop or fenestration for the celiac artery, or intentional coverage of the celiac artery. In the latter case, adequate collateral supply to the upper gastrointestinal tract is crucial. Collateral arteries joining the celiac and the superior mesenteric arteries are well characterized in patients with chronic celiac stenosis or occlusion. Are these collateral pathways sufficient also for sudden iatrogenic closure of the celiac artery? By performing a preoperative angiography of the superior mesenteric artery with temporary balloon occlusion of the celiac artery, collateral capacity between the two vessels can be tested in advance. Exact positioning of the distal end of a large thoracic stent-graft can be challenging and require special considerations and techniques. Most case series in the literature support the efficacy and the safety of intentional celiac covering. However, there are also reports of ischemic foregut complications that could be associated to the procedure. Taken together, in the large majority of patients, it appears that intentional celiac coverage can be done safely provided that sufficient collateral function have been demonstrated in advance.