Abstract
Many methods used for precise fault detection in salient pole synchronous generators (SPSGs) often require a priori knowledge of the healthy case, but this requirement impedes application of the methods since an accurate analysis of different machine quantity waveforms is not usually carried out during commissioning. The inspection and maintenance processes in SPSGs are also costly and time consuming; therefore, reliable methods that can detect and discriminate between different faults without comparison with the healthy condition are highly desirable. This article proposes a precise method for detection and discrimination between different fault types in the SPSG. The method does not require healthy machine data and is applied to diagnose both interturn short circuits (ITSCs) in the field winding and dynamic eccentricities (DEs). The proposed nonintrusive detection algorithm is based on advanced signal analysis of stray magnetic field data and can be applied during SPSG operation. The method is highly precise for monitoring the condition of the rotor field winding and yields a unique pattern for diagnosing possible ITSC faults. Moreover, a distinctive pattern for the DE fault enables the discrimination between both considered failures, even if they are present at the same time. The proposed method is validated through finite-element modeling and experimentally on 100-kVA and 22-MVA SPSGs to demonstrate its applicability in real power plants.Keywords
Funding Information
- Norwegian Research Centre for Hydropower Technology
- Norges Forskningsråd (257588)
This publication has 29 references indexed in Scilit:
- Noninvasive Detection of Winding Short-Circuit Faults in Salient Pole Synchronous Machine With Squirrel-Cage DamperIEEE Transactions on Industry Applications, 2018
- Evaluation of the Detectability of Electromechanical Faults in Induction Motors Via Transient Analysis of the Stray FluxIEEE Transactions on Industry Applications, 2018
- Experience with Hydro-Generator Turn-to-Turn Insulation Fault, Investigation, and Recommendation for New Stator Winding Design and Protection2018
- A review of condition monitoring of induction motors based on stray flux2017
- Analytic method for eccentricity fault diagnosis in salient-pole synchronous generators2017
- Strategic fault diagnosis approach for hydrogenerator shaft current discharges2016
- Synchronous Generators2015
- Detection of Broken Damper Bars of a Turbo Generator by the Field Winding.Renewable Energy and Power Quality Journal, 2004
- Broken damper bar detection studies using flux probe measurements and time-stepping finite element analysis for salient-pole synchronous machines2003
- A Practical Guide to Wavelet AnalysisBulletin of the American Meteorological Society, 1998