Arne Nysveen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arne Nysveen has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Robert Nilssen
Department of Electric Power Engineering, Norwegian University Science and Technology, Trondheim, Norway
21 shared publicationsMostafa Valavi
Department of Electrical Power Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, 7034, Norway
18 shared publications- Hossein Ehya
Department of Electric Energy, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
9 shared publications Anyuan Chen
Norwegian Univ Sci & Technol, Dept Elect Energy, N-7491 Trondheim, Norway
7 shared publicationsR. Nilssen
5 shared publications- Abdelghaffar Amoka Abdelmalik
Department of Physics, Ahmadu Bello University Zaria, Nigeria
4 shared publications
Latest Publications
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1686-1689
Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test
The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (2) , 1686-1689
Sensitive Detection of Shorted Field Winding Turns in Salient Pole Synchronous Machines With High Frequency Pole Drop Test
The pole drop test is the most widely accepted test for detecting short circuits in the field winding of salient pole synchronous machines (SPSM). Although it is a simple and effective test, there are concerns on the reliability due to the inherent asymmetry between the poles, especially for cases where the percentage of shorted turns is low. Considering that this is the primary test used in industry for detecting shorted field turns in SPSMs, improving the sensitivity of the test is highly desirable for reliable fault detection. In this paper, it is shown that the sensitivity of the pole drop test can be significantly improved by increasing the excitation frequency of the test voltage above the 50/60 Hz currently used, which is not reported elsewhere. An electrical equivalent circuit analysis and an experimental study on a 4 pole, 30 kVA synchronous motor and a 14 pole, 100 kVA hydrogenator prototype are given to verify the claims made.
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 6045-6055
Virtual-Stator Loss Model for Synchronous Generators With Fractional-Slot Winding
In synchronous generators, the end-region field can cause additional losses at clamping structures and stator end core. It can be a computational challenge to solve the end-region field of synchronous generators featuring fractional-slot winding. With a minor modification of the number of stator slots, the winding scheme can be changed to the integral slot and, consequently, a virtual stator is derived. The model size of a three-dimensional (3D) Virtual-stator Loss Model (VLM) is much smaller than the Real-stator Loss Model (RLM), and the computational burden is substantially alleviated. This paper delves into the theory underpinning VLM and its practical implementation. From the perspective of two-dimensional (2D) analysis, 2D VLM demonstrates close results in field analysis and loss computation when compared to 2D RLM, indicating the potential of the 3D VLM in accurately computing end-region losses. The 3D VLM is used to compute the end-region losses at different operating points. It concludes that the 3D VLM can keep the essential nature of the loss-producing mechanism while dramatically mitigating the computation hurdles. Lab tests at a 100 kVA salient-pole synchronous generator prove that the investigation approach employed in the paper is trustworthy.
- 2 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 6045-6055
Virtual-Stator Loss Model for Synchronous Generators With Fractional-Slot Winding
In synchronous generators, the end-region field can cause additional losses at clamping structures and stator end core. It can be a computational challenge to solve the end-region field of synchronous generators featuring fractional-slot winding. With a minor modification of the number of stator slots, the winding scheme can be changed to the integral slot and, consequently, a virtual stator is derived. The model size of a three-dimensional (3D) Virtual-stator Loss Model (VLM) is much smaller than the Real-stator Loss Model (RLM), and the computational burden is substantially alleviated. This paper delves into the theory underpinning VLM and its practical implementation. From the perspective of two-dimensional (2D) analysis, 2D VLM demonstrates close results in field analysis and loss computation when compared to 2D RLM, indicating the potential of the 3D VLM in accurately computing end-region losses. The 3D VLM is used to compute the end-region losses at different operating points. It concludes that the 3D VLM can keep the essential nature of the loss-producing mechanism while dramatically mitigating the computation hurdles. Lab tests at a 100 kVA salient-pole synchronous generator prove that the investigation approach employed in the paper is trustworthy.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Material Characterization and Stator Core Loss Computation of Synchronous Generators with Stacking Force Accounted
In electrical machines, electrical steels are stacked together with forces to maintain mechanical rigidity. This stacking force alters the magnetic properties of laminated steel and consequently changes its loss behavior. Failing to consider the stacking force can lead to increased errors in core loss computation. This paper investigates the impact of stacking force on the stator core loss of synchronous generators. Magnetic properties (magnetization and loss) of the electrical steel M400- 50A are measured in a special-designed ring core test, and during the test, the ring core is subjected to normal pressing force controlled in closed loop. This test reveals that stacking stress reduces permeability and results in more specific loss for a given flux density. Furthermore, it demonstrates that the weakening of magnetic properties is nonlinearly correlated with the applied stress. Two core loss models are used to compute the stator core loss of a 100 kVA synchronous generator. Lab tests conducted on this generator demonstrate a noticeable improvement in computational accuracy when the stacking force is considered. Among the two core loss models, the two-component frequency domain Bertotti method requires less implementation effort and yields better accuracy.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-10
Material Characterization and Stator Core Loss Computation of Synchronous Generators with Stacking Force Accounted
In electrical machines, electrical steels are stacked together with forces to maintain mechanical rigidity. This stacking force alters the magnetic properties of laminated steel and consequently changes its loss behavior. Failing to consider the stacking force can lead to increased errors in core loss computation. This paper investigates the impact of stacking force on the stator core loss of synchronous generators. Magnetic properties (magnetization and loss) of the electrical steel M400- 50A are measured in a special-designed ring core test, and during the test, the ring core is subjected to normal pressing force controlled in closed loop. This test reveals that stacking stress reduces permeability and results in more specific loss for a given flux density. Furthermore, it demonstrates that the weakening of magnetic properties is nonlinearly correlated with the applied stress. Two core loss models are used to compute the stator core loss of a 100 kVA synchronous generator. Lab tests conducted on this generator demonstrate a noticeable improvement in computational accuracy when the stacking force is considered. Among the two core loss models, the two-component frequency domain Bertotti method requires less implementation effort and yields better accuracy.
- 16 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
Computation of Core Losses in Electrical Steel Laminations With Impacts of Normal Flux and PWM Switching Considered
Normal flux (perpendicular to the lamination plane) and pulse width modulation (PWM) can have significant impacts on the losses of steel laminations, e.g. in converter-fed synchronous machines or transformers. This paper proposes a model for computing the losses of steel laminations with the impacts of normal flux and PWM switching considered. The total core losses are computed by modifying the core losses of a reference sinusoidal case with the global statistics about supply voltage. A dedicated test setup was developed to validate the loss model. The measurement shows that the proposed model can compute core losses with acceptable accuracy, reasonable computing time, and moderate demand for computing resources.
- 16 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 60 (3) , 1-4
Computation of Core Losses in Electrical Steel Laminations With Impacts of Normal Flux and PWM Switching Considered
Normal flux (perpendicular to the lamination plane) and pulse width modulation (PWM) can have significant impacts on the losses of steel laminations, e.g. in converter-fed synchronous machines or transformers. This paper proposes a model for computing the losses of steel laminations with the impacts of normal flux and PWM switching considered. The total core losses are computed by modifying the core losses of a reference sinusoidal case with the global statistics about supply voltage. A dedicated test setup was developed to validate the loss model. The measurement shows that the proposed model can compute core losses with acceptable accuracy, reasonable computing time, and moderate demand for computing resources.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 6792-6803
Control Methods for Operation of Pumped Storage Plants With Full-Size Back-to-Back Converter Fed Synchronous Machines
A full-size converter-fed synchronous machine (CFSM) technology is emerging as the most flexible system for pumped storage plants for efficient operation in a wide range of water flows, which is not the case in existing power plants with fixed-speed synchronous machines. This article presents steady-state control strategies to execute the variable speed operation of the pumped storage power plants in both turbine and pump mode using a full-size back-to-back converter. Furthermore, the starting method of the power plant in pump and turbine mode from a standstill is proposed. In addition, the seamless transition of operating modes from the turbine to pump mode and vice versa is presented, which is an essential feature required to adapt to the varying power generation from renewable energy sources like solar and wind. The behavior of the power plant during a voltage dip on ac grid, and the low-voltage ride-through (LVRT) capability in both turbine and pump modes are also presented. The proposed control strategies are experimentally verified with a 100 kVA machine and converter setup with an emulated reversible pump turbine (RPT) and waterways.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 6792-6803
Control Methods for Operation of Pumped Storage Plants With Full-Size Back-to-Back Converter Fed Synchronous Machines
A full-size converter-fed synchronous machine (CFSM) technology is emerging as the most flexible system for pumped storage plants for efficient operation in a wide range of water flows, which is not the case in existing power plants with fixed-speed synchronous machines. This article presents steady-state control strategies to execute the variable speed operation of the pumped storage power plants in both turbine and pump mode using a full-size back-to-back converter. Furthermore, the starting method of the power plant in pump and turbine mode from a standstill is proposed. In addition, the seamless transition of operating modes from the turbine to pump mode and vice versa is presented, which is an essential feature required to adapt to the varying power generation from renewable energy sources like solar and wind. The behavior of the power plant during a voltage dip on ac grid, and the low-voltage ride-through (LVRT) capability in both turbine and pump modes are also presented. The proposed control strategies are experimentally verified with a 100 kVA machine and converter setup with an emulated reversible pump turbine (RPT) and waterways.
- 13 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (2) , 2008-2017
An Expeditious Algorithm for Identification and Classification of Rotor Faults in Salient Pole Synchronous Generators
Providing secure electricity depends on the reliable operation of the synchronous generators in power plants. Interturn short-circuit (ITSC) and dynamic eccentricity (DE) faults are among the most prevalent fault types in wound field synchronous generators (WFSGs). Among the various signals used to detect faults, such as current, voltage, and vibration, the stray magnetic field provides higher sensitivity for early-stage ITSC and DE detection. The introduced detection methods rely on comparison of various signals frequency spectrum's from fault and healthy generators. However, obtaining a frequency spectrum of a healthy synchronous generator that has been operating for decades in a power plant is almost impossible. A unique pattern is introduced using fast Fourier transform that can be implemented on a low-end microcontroller and ideal for Internet of Things solutions. The efficacy of the proposed pattern is examined by finite element modeling and validated on a 100 kVA WFSG setup in the laboratory and field test in a power plant with a power rating of 22 MVA.
- 13 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (2) , 2008-2017
An Expeditious Algorithm for Identification and Classification of Rotor Faults in Salient Pole Synchronous Generators
Providing secure electricity depends on the reliable operation of the synchronous generators in power plants. Interturn short-circuit (ITSC) and dynamic eccentricity (DE) faults are among the most prevalent fault types in wound field synchronous generators (WFSGs). Among the various signals used to detect faults, such as current, voltage, and vibration, the stray magnetic field provides higher sensitivity for early-stage ITSC and DE detection. The introduced detection methods rely on comparison of various signals frequency spectrum's from fault and healthy generators. However, obtaining a frequency spectrum of a healthy synchronous generator that has been operating for decades in a power plant is almost impossible. A unique pattern is introduced using fast Fourier transform that can be implemented on a low-end microcontroller and ideal for Internet of Things solutions. The efficacy of the proposed pattern is examined by finite element modeling and validated on a 100 kVA WFSG setup in the laboratory and field test in a power plant with a power rating of 22 MVA.
- 24 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 67, 1-2
Losses Caused by End-region Field in Synchronous Generators at Different Operating Conditions
It is challenging to measure losses caused by end-region field in real synchronous generators, because of accessibility and cost. This paper presents a dedicated test setup to emulate the field experienced by clamping structures and stator end core, and validate loss models. Measurements show that the loss model employed has an averaged error of 3.6%. Investigation of a 100 kVA synchronous generator shows that these losses are heavily dependent on operating conditions. The case with Leading PF has the highest loss, and the dominant loss component for all the cases is eddy current loss in clamping structures.
- 24 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 67, 1-2
Losses Caused by End-region Field in Synchronous Generators at Different Operating Conditions
It is challenging to measure losses caused by end-region field in real synchronous generators, because of accessibility and cost. This paper presents a dedicated test setup to emulate the field experienced by clamping structures and stator end core, and validate loss models. Measurements show that the loss model employed has an averaged error of 3.6%. Investigation of a 100 kVA synchronous generator shows that these losses are heavily dependent on operating conditions. The case with Leading PF has the highest loss, and the dominant loss component for all the cases is eddy current loss in clamping structures.
- 13 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (11) , 11675-11685
Advanced Fault Detection of Synchronous Generators Using Stray Magnetic Field
Many methods used for precise fault detection in salient pole synchronous generators (SPSGs) often require a priori knowledge of the healthy case, but this requirement impedes application of the methods since an accurate analysis of different machine quantity waveforms is not usually carried out during commissioning. The inspection and maintenance processes in SPSGs are also costly and time consuming; therefore, reliable methods that can detect and discriminate between different faults without comparison with the healthy condition are highly desirable. This article proposes a precise method for detection and discrimination between different fault types in the SPSG. The method does not require healthy machine data and is applied to diagnose both interturn short circuits (ITSCs) in the field winding and dynamic eccentricities (DEs). The proposed nonintrusive detection algorithm is based on advanced signal analysis of stray magnetic field data and can be applied during SPSG operation. The method is highly precise for monitoring the condition of the rotor field winding and yields a unique pattern for diagnosing possible ITSC faults. Moreover, a distinctive pattern for the DE fault enables the discrimination between both considered failures, even if they are present at the same time. The proposed method is validated through finite-element modeling and experimentally on 100-kVA and 22-MVA SPSGs to demonstrate its applicability in real power plants.
- 13 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (11) , 11675-11685
Advanced Fault Detection of Synchronous Generators Using Stray Magnetic Field
Many methods used for precise fault detection in salient pole synchronous generators (SPSGs) often require a priori knowledge of the healthy case, but this requirement impedes application of the methods since an accurate analysis of different machine quantity waveforms is not usually carried out during commissioning. The inspection and maintenance processes in SPSGs are also costly and time consuming; therefore, reliable methods that can detect and discriminate between different faults without comparison with the healthy condition are highly desirable. This article proposes a precise method for detection and discrimination between different fault types in the SPSG. The method does not require healthy machine data and is applied to diagnose both interturn short circuits (ITSCs) in the field winding and dynamic eccentricities (DEs). The proposed nonintrusive detection algorithm is based on advanced signal analysis of stray magnetic field data and can be applied during SPSG operation. The method is highly precise for monitoring the condition of the rotor field winding and yields a unique pattern for diagnosing possible ITSC faults. Moreover, a distinctive pattern for the DE fault enables the discrimination between both considered failures, even if they are present at the same time. The proposed method is validated through finite-element modeling and experimentally on 100-kVA and 22-MVA SPSGs to demonstrate its applicability in real power plants.
- Open Access
- 1 August 2021
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 587
Testing of an MgB2 coil for a wind turbine generator pole
- 1 August 2021
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 587
Open AccessTesting of an MgB2 coil for a wind turbine generator pole
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (4) , 3654-3665
Performance Evaluation of Signal Processing Tools Used for Fault Detection of Hydrogenerators Operating in Noisy Environments
Signal processing plays a crucial role in addressing failures in electrical machines. Experimental data are never perfect due to the intrusion of undesirable fluctuations unrelated to the investigated phenomenon, namely so-called noise. Noise has disturbing effects on the measurement data and, in the same way, could diminish or mask the fault patterns in feature extraction using different signal processors. This article introduces various types of noise occurring in an industrial environment. Several measurements are performed in the laboratory and power plants to identify the dominant type of noise. Fault detection in a custom-made 100-kVA synchronous generator under an interturn short-circuit fault is also studied using measurements of the air-gap magnetic field. Signal processing tools such as fast Fourier transform, short-time Fourier transform (STFT), discrete wavelet transform, continuous wavelet transform (CWT), and time-series data mining are used to diagnose the faults, with a central focus on additive noise impacts on processed data. Two novel patterns are introduced based on STFT and CWT for interturn short-circuit fault detection of synchronous generators that do not need a priori knowledge of a healthy machine. Useful methods are presented for hardware noise rejection.
- 7 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 57 (4) , 3654-3665
Performance Evaluation of Signal Processing Tools Used for Fault Detection of Hydrogenerators Operating in Noisy Environments
Signal processing plays a crucial role in addressing failures in electrical machines. Experimental data are never perfect due to the intrusion of undesirable fluctuations unrelated to the investigated phenomenon, namely so-called noise. Noise has disturbing effects on the measurement data and, in the same way, could diminish or mask the fault patterns in feature extraction using different signal processors. This article introduces various types of noise occurring in an industrial environment. Several measurements are performed in the laboratory and power plants to identify the dominant type of noise. Fault detection in a custom-made 100-kVA synchronous generator under an interturn short-circuit fault is also studied using measurements of the air-gap magnetic field. Signal processing tools such as fast Fourier transform, short-time Fourier transform (STFT), discrete wavelet transform, continuous wavelet transform (CWT), and time-series data mining are used to diagnose the faults, with a central focus on additive noise impacts on processed data. Two novel patterns are introduced based on STFT and CWT for interturn short-circuit fault detection of synchronous generators that do not need a priori knowledge of a healthy machine. Useful methods are presented for hardware noise rejection.