Comparison of Force During the Endotracheal Intubation of Commercial Simulation Manikins
Authors:
Open Access
- 20 August 2023
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 15 (8) , e43808
Abstract
Background Medical simulation allows clinicians to safely practice the procedural skill of endotracheal intubation. Applied force to oropharyngeal structures increases the risk of patient harm, and video laryngoscopy (VL) requires less force to obtain a glottic view. It is unknown how much force is required to obtain a glottic view using commercially available simulation manikins and if variability exists. This study compares laryngoscopy force for a modified Cormack-Lehane (CL) grade I view in both normal and difficult airway scenarios between three commercially available simulation manikins. Methods Experienced clinicians (≥2 years experience) were recruited to participate from critical care, emergency medicine, and anesthesia specialties. A C-MAC size 3 VL blade was equipped with five force resistor reading (FSR) sensors (four concave surfaces, one convex), measuring resistance (Ohms) in response to applied pressure (1-100 Newtons). The study occurred in a university simulation lab. Using a randomized sequence, 49 physicians performed intubations on three manikins (Laerdal SimMan 3GPlus, Gaumard Hal S3201, CAE Apollo) in normal and difficult airway scenarios. The outcomes were sensor mean pressure, peak force, and CL grade. Summary statistics were calculated. Generalized estimating equations (GEEs) conducted for both scenarios assessed changes in pressure measured in three manikins while accounting for correlated responses of individuals assigned in random order. Paired t-test assessed for the in-manikin difference between scenarios. STATA/BE v17 (R) was used for analysis; results interpreted at type I error alpha is 0.05. Results Participants included 49 experienced clinicians. Mean years’ experience was 4(±6.6); median prior intubations were 80 (IQR 50-400). Mean individual sensor pressure varied within scenarios depending on manikin (p<0.001). Higher mean forces were used in difficult scenarios (603.4±128.9, 611.1±101.4, 467.5±72.4 FSR) than normal (462.5±121.9, 596.0±90.5, 290.6±63.2 FSR) for each manikin (p<0.001). All manikins required more peak force in the difficult scenario (p<0.03). The highest mean forces (Laerdal, CAE, difficult scenario) were associated with the higher frequency of grade 2A views (p<0.001). The Gaumard manikin was rated most realistic in terms of force required to intubate. Conclusion Commercially available high-fidelity manikins had significant variability in laryngoscopy force in both normal and difficult airway scenarios. In difficult airway scenarios, significant variability existed in CL grade between manikin brands. Experienced clinicians rated Gaumard Hal as the most realistic force applied during endotracheal intubation.Keywords
This publication has 25 references indexed in Scilit:
- Difficult Airway Management in the Emergency Department: GlideScope Videolaryngoscopy Compared to Direct LaryngoscopyThe Journal of Emergency Medicine, 2012
- Tracheal Intubation in the Emergency Department: A Comparison of GlideScope® Video Laryngoscopy to Direct Laryngoscopy in 822 IntubationsThe Journal of Emergency Medicine, 2012
- Measurement of forces applied during Macintosh direct laryngoscopy compared with GlideScope ® videolaryngoscopy*Anaesthesia, 2012
- Force and pressure distribution using Macintosh and GlideScope laryngoscopes in normal and difficult airways: a manikin studyBritish Journal of Anaesthesia, 2011
- Forces Applied to the Maxillary Incisors During Video-Assisted IntubationAnesthesia & Analgesia, 2009
- Emergency Tracheal Intubation: Complications Associated with Repeated Laryngoscopic AttemptsAnesthesia & Analgesia, 2004
- Neurocirculatory responses to intubation with either an endotracheal tube or a laryngeal mask airway in humansJournal of Clinical Anesthesia, 1996
- Controlling the hemodynamic response to laryngoscopy and endotracheal intubationJournal of Clinical Anesthesia, 1996
- Hemodynamic and catecholamine responses to laryngoscopy with vs. without endotracheal intubationActa Anaesthesiologica Scandinavica, 1991
- Complications Related to the Pressor Response to Endotracheal IntubationAnesthesiology, 1977