KHKate Hughes

Kate Hughes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kate Hughes has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Development of an Integrated Virtual Reality (VR)-Based Training System for Difficult Airway Management

    by Saurabh Jain, Bijoy Dripta Barua Chowdhury, Jarrod M. Mosier, Vignesh Subbian, Kate Hughes, Young-Jun Son

    For over 40 years, airway management simulation has been a cornerstone of medical training, aiming to reduce procedural risks for critically ill patients. However, existing simulation technologies often lack the versatility and realism needed to replicate the cognitive and physical challenges of complex airway management scenarios. We developed a novel Virtual Reality (VR)-based simulation system designed to enhance immersive airway management training and research. This system integrates physical and virtual environments with an external sensory framework to capture high-fidelity data on user performance. Advanced calibration techniques ensure precise positional tracking and realistic physics-based interactions, providing a cohesive mixed-reality experience. Validation studies conducted in a dedicated medical training center demonstrated the system’s effectiveness in replicating real-world conditions. Positional calibration accuracy was achieved within 0.1 cm, with parameter calibrations showing no significant discrepancies. Validation using Pre- and post-simulation surveys indicated positive feedback on training aspects, perceived usefulness, and ease of use. These results suggest that the system offers a significant improvement in procedural and cognitive training for high-stakes medical environments.


  • Open Access

    Comparison of Force During the Endotracheal Intubation of Commercial Simulation Manikins

    by Kate E Hughes, Tariqul Islam, Benjamin Co, Merryl Lopido, Neil L. McNinch, David Biffar, Vignesh Subbian, Young-Jun Son, Jarrod M. Mosier

    Background Medical simulation allows clinicians to safely practice the procedural skill of endotracheal intubation. Applied force to oropharyngeal structures increases the risk of patient harm, and video laryngoscopy (VL) requires less force to obtain a glottic view. It is unknown how much force is required to obtain a glottic view using commercially available simulation manikins and if variability exists. This study compares laryngoscopy force for a modified Cormack-Lehane (CL) grade I view in both normal and difficult airway scenarios between three commercially available simulation manikins. Methods Experienced clinicians (≥2 years experience) were recruited to participate from critical care, emergency medicine, and anesthesia specialties. A C-MAC size 3 VL blade was equipped with five force resistor reading (FSR) sensors (four concave surfaces, one convex), measuring resistance (Ohms) in response to applied pressure (1-100 Newtons). The study occurred in a university simulation lab. Using a randomized sequence, 49 physicians performed intubations on three manikins (Laerdal SimMan 3GPlus, Gaumard Hal S3201, CAE Apollo) in normal and difficult airway scenarios. The outcomes were sensor mean pressure, peak force, and CL grade. Summary statistics were calculated. Generalized estimating equations (GEEs) conducted for both scenarios assessed changes in pressure measured in three manikins while accounting for correlated responses of individuals assigned in random order. Paired t-test assessed for the in-manikin difference between scenarios. STATA/BE v17 (R) was used for analysis; results interpreted at type I error alpha is 0.05. Results Participants included 49 experienced clinicians. Mean years’ experience was 4(±6.6); median prior intubations were 80 (IQR 50-400). Mean individual sensor pressure varied within scenarios depending on manikin (p<0.001). Higher mean forces were used in difficult scenarios (603.4±128.9, 611.1±101.4, 467.5±72.4 FSR) than normal (462.5±121.9, 596.0±90.5, 290.6±63.2 FSR) for each manikin (p<0.001). All manikins required more peak force in the difficult scenario (p<0.03). The highest mean forces (Laerdal, CAE, difficult scenario) were associated with the higher frequency of grade 2A views (p<0.001). The Gaumard manikin was rated most realistic in terms of force required to intubate. Conclusion Commercially available high-fidelity manikins had significant variability in laryngoscopy force in both normal and difficult airway scenarios. In difficult airway scenarios, significant variability existed in CL grade between manikin brands. Experienced clinicians rated Gaumard Hal as the most realistic force applied during endotracheal intubation.


  • Open Access

    Impact of Sports Medicine and Orthopedic Surgery Rotations on Musculoskeletal Knowledge in Residency

    by William Denq, James D. Fox, Allison Lane, Beatrice Caballero, Brandon Godfrey, Jay Yim, Kate E Hughes, Thomas M. Cahir, Anna Waterbrook

    Musculoskeletal (MSK) complaints and injuries comprise 18.7% of emergency department visits. However, only 61% of emergency physicians (EP) pass a validated written Freedman and Bernstein MSK examination (FB-MSK). Educational interventions such as a primary care sports medicine (PCSM) rotation aid in MSK residency education. This study utilizes a validated MSK examination to evaluate and compare MSK knowledge acquisition following a traditional orthopedic rotation and a PCSM rotation. Forty-nine interns were recruited to participate in this study over two academic years. The FB-MSK was administered to all participants at the start of residency. Participants were divided into two groups based on their residency sites; one group completed a traditional four-week orthopedic surgery rotation and the second group completed a four-week PCSM rotation. Forty-six of the forty-nine participants were administered the FB-MSK after completion of their rotations. Individual post-rotation scores significantly improved regardless of rotation (mean difference 2.78, p<0.001; 95% CI 2.05-3.52). The orthopedic surgery group significantly improved (mean difference 2.84, pp=0.002; 95% CI 1.23-4.07). There was no significant difference in pre-rotation scores between the two groups (p=0.86; 95% CI -2.13 to 1.79). There was no significant difference in post-rotation scores between the two groups (p=0.66; 95% CI -1.98 to 1.26). There was no significant difference in mean score improvement between the two groups (p=0.81; 95% CI -1.33 to 1.69). This study demonstrates significant MSK knowledge acquisition and no difference in the level of knowledge acquisition after completion of either traditional orthopedic surgery or PCSM residency rotation.


  • Advanced closed-loop communication training: the blindfolded resuscitation

    by Kate E Hughes, Patrick G Hughes, Thomas Cahir, Jennifer Plitt, Vivienne Ng, Edward Bedrick, Rami A Ahmed

    Closed-loop communication (CLC) improves task efficiency and decreases medical errors; however, limited literature on strategies to improve real-time use exist. The primary objective was whether blindfolding a resuscitation leader was effective to improve crisis resource management (CRM) skills, as measured by increased frequency of CLC. Secondary objectives included whether blindfolding affected overall CRM performance or perceived task load. Participants included emergency medicine (EM) or EM/paediatric dual resident physicians. Participants completed presurveys, were block randomised into intervention (blindfolded) or control groups, lead both adult and paediatric resuscitations and completed postsurveys before debriefing. Video recordings of the simulations were reviewed by simulation fellowship-trained EM physicians and rated using the Ottawa CRM Global Rating Scale (GRS). Frequency of CLC was assessed by one rater via video review. Summary statistics were performed. Intraclass correlation coefficient was calculated. Data were analysed using R program for analysis of variance and regression analysis. There were no significant differences between intervention and control groups in any Ottawa CRM GRS category. Postgraduate year (PGY) significantly impacts all Ottawa GRS categories. Frequency of CLC use significantly increased in the blindfolded group (31.7, 95% CI 29.34 to 34.1) vs the non-blindfolded group (24.6, 95% CI 21.5 to 27.7). Participant’s self-rated perceived NASA Task Load Index scores demonstrated no difference between intervention and control groups via a Wilcoxon rank sum test. Blindfolding the resuscitation leader significantly increases frequency of CLC. The blindfold code training exercise is an advanced technique that may increase the use of CLC.


  • Open Access

    Development of a Medical Student Cardiopulmonary Resuscitation Elective to Promote Education and Community Outreach

    by Ashish Panchal, Samuel Keim, Gordon Ewy, Karl Kern, Kate E Hughes, Daniel Beskind

    Introduction: One of the barriers to improving cardiac arrest survival is the low rate of cardiopulmonary resuscitation (CPR) provision. Identifying this as a public health issue, many medical students often assist in training the community in CPR. However, these experiences are often short and are not associated with structured resuscitation education, limiting the student's and the community's learning. In this assessment, we identified a need and developed a curriculum, including defined goals and objectives, for an undergraduate medical education (UME) elective in CPR. Methods: At an academic university environment with a strong UME program, we developed a longitudinal UME elective in CPR. The curriculum is a four-year longitudinal experience, which satisfies two weeks of their fourth year of medical school. The curriculum includes structured training over the four-year period in the fundamentals of resuscitation science (through didactics, journal club, and hands-on skills training), in addition to structured community CPR teaching. The elective concludes with a final hands-on summative appraisal. Data concerning medical student program enrollment, CPR training events conducted, venues of events, and the number of individuals trained were collected over a five-year period. Results: The CPR elective was developed with clear goals and objectives based on identified needs. Over the five-year period, 186 medical students completed the CPR longitudinal elective, accounting for 8.4% of the total medical student population. Students completed curriculum requirements and satisfied both didactic and hands-on training with all students passing the final summative appraisal. Over the five-year period, students trained 8,694 people in bystander CPR. The summative evaluation had a 100% pass rate. Conclusion: Implementation of a longitudinal CPR elective improved resuscitation science education for medical students and fostered increased community CPR training. This describes one local effort to improve resuscitation science education and training for medical students. Further work will need to be done to evaluate the impact of UME resuscitation curricula on medical student career choice and resuscitation outcomes.


  • Open Access

    Evaluation of an Innovative Bleeding Cricothyrotomy Model

    by Kate E Hughes, David Biffar, Eze O Ahanonu, Thomas M. Cahir, Allan Hamilton, John C. Sakles

    Emergency medicine (EM) residents are required to perform a cricothyrotomy during training as per the Accreditation Council for Graduate Medical Education (ACGME) guidelines. Cricothyrotomy is a rare procedure, comprising 0.45% of emergency department airway management procedures. Procedural competence in utilizing a realistic trainer is of utmost importance. We have developed a cricothyrotomy trainer using a fused deposition modeling (FDM) three-dimensional (3D) printer and innovative bleeding tissue to enhance fidelity. We aim to evaluate the trainer’s realism. Implementation occurred during a difficult airway educational lab for EM residents in April 2018. Participants completed anonymous written surveys after performing a cricothyrotomy on the trainer. The survey evaluated the realism of the trainer and compared it to other available models by utilizing five-point visual analog scales (VAS). The participants rated their comfort level in performing the procedure pre- and post-educational lab on a five-point VAS. Demographic data included postgraduate year, prior clinical cricothyrotomy experience as a primary operator versus as an assistant, and previous trainer experience. The survey included open-response suggestions for trainer improvement. Forty-three EM residents completed the survey (82.7%, 43/52). The mean realism rating of the trainer was 3.81 (95% CI = 3.54-4.1). The participants reported previous training on cadaver (62.8%, 27/43), porcine (46.5%, 20/43), and manikin (67.4%, 29/43) models prior to using this trainer. The bleeding cricothyrotomy trainer was rated higher than other models (4.45, 95% CI = 4.28-4.63). Participants noted improved comfort with performing the cricothyrotomy after the educational lab (average improvement of 1.23±0.75). Participants specifically commented on the realism of the bleeding and skin texture; however, they also recommended a reduction in the size of the cricothyroid membrane space. The innovative bleeding cricothyrotomy trainer has greater fidelity and reported superiority when compared to other commonly used nonbleeding models. This trainer provides a more advanced platform to teach an infrequent yet critical procedural skill to emergency medicine residents.


  • Septic Thromboembolic Stroke via Atrial-Esophageal Fistula as a Delayed Complication of Cardiac Ablation (P6.018)

    by Talal Derani, Saqib Chaudhry, Gautam Sachdeva, Daniel Long, Kate Hughes, Suwen Kumar, Howard Chang, Anmar Razak