Failure Analysis of Transmission Line Towers
- 1 June 2011
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Performance of Constructed Facilities
- Vol. 25 (3) , 231-240
Abstract
Transmission line towers, though designed per code provisions, may fail during mandatory testing required in many countries. Different types of premature failures that were observed during full-scale testing of transmission line towers at Tower Testing and Research Station, Structural Engineering Research Centre, Chennai (CSIR-SERC) are studied, and the results are discussed in detail. The failures are modeled using finite-element software, and the analytical results and the test results are compared with various code provisions. The nonlinear finite-element analysis program NE-Nastran was used to model the elastoplastic behavior of towers. Bracing members with slenderness ratios above 170 become ineffective, even though they have to carry insignificant forces. Importance of design assumptions and connection detailing in overall performance of towers were studied. Nonlinear finite-element analysis is useful in understanding the system behavior and for prediction of the failure pattern and ultimate load. B...Keywords
This publication has 5 references indexed in Scilit:
- Failure analysis of transmission towersEngineering Failure Analysis, 2009
- Elastoplastic large deformation analysis of a lattice steel tower structure and comparison with full-scale testsJournal of Constructional Steel Research, 2007
- Non-linear behaviour of lattice panel of angle towersJournal of Constructional Steel Research, 2001
- Design of Latticed Steel Transmission Structures2000
- Behavior of Cross-Bracing in Latticed TowersJournal of Structural Engineering, 1998