Robust Direct Aperture Optimization for Radiation Therapy Treatment Planning
- 1 July 2022
- journal article
- research article
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in INFORMS Journal on Computing
- Vol. 34 (4) , 2017-2038
Abstract
Intensity-modulated radiation therapy (IMRT) allows for the design of customized, highly conformal treatments for cancer patients. Creating IMRT treatment plans, however, is a mathematically complex process, which is often tackled in multiple, simpler stages. This sequential approach typically separates radiation dose requirements from mechanical deliverability considerations, which may result in suboptimal treatment quality. For patient health to be considered paramount, holistic models must address these plan elements concurrently, eliminating quality loss between stages. This combined direct aperture optimization (DAO) approach is rarely paired with uncertainty mitigation techniques, such as robust optimization, because of the inherent complexity of both parts. This paper outlines a robust DAO (RDAO) model and discusses novel methodologies for efficiently integrating salient constraints. Because the highly complex RDAO model is difficult to solve, an original candidate plan generation (CPG) heuristic is proposed. The CPG produces rapid, high-quality, feasible plans, which are immediately clinically viable and can also be used to generate a feasible incumbent solution for warm-starting the RDAO model. Computational results obtained using clinical patient data sets with motion uncertainty show the benefit of incorporating the CPG, in terms of both the first incumbent solution and final output plan quality. Summary of Contribution: This paper describes the derivation, implementation, and solution of a large-scale robust direct aperture optimization model for the problem of intensity-modulated radiation therapy planning for cancer treatment. The contribution to operations research lies in the design of a novel mixed-integer programming model that describes all salient mechanical and clinical deliverability requirements for modern delivery equipment. Because of the large-scale nature of the resulting model, a novel tractable heuristic for generating high-quality, feasible treatment plans, as well as warm starts for the full model, is proposed and demonstrated on five clinical patient data sets.Keywords
All Related Versions
This publication has 53 references indexed in Scilit:
- Cancer and Radiation Therapy: Current Advances and Future DirectionsInternational Journal of Medical Sciences, 2012
- Mathematical optimization in intensity modulated radiation therapyAnnals of Operations Research, 2009
- Direct aperture optimization as a means of reducing the complexity of intensity modulated radiation therapy plansRadiation Oncology, 2009
- Efficient schemes for robust IMRT treatment planningPhysics in Medicine & Biology, 2006
- Direct aperture optimization of breast IMRT and the dosimetric impact of respiration motionPhysics in Medicine & Biology, 2006
- A robust approach to IMRT optimizationPhysics in Medicine & Biology, 2006
- An examination of the number of required apertures for step-and-shoot IMRTPhysics in Medicine & Biology, 2005
- Direct aperture optimization: A turnkey solution for step‐and‐shoot IMRTMedical Physics, 2002
- Improved leaf sequencing reduces segments or monitor units needed to deliver IMRT using multileaf collimatorsMedical Physics, 2001
- Robust solutions of uncertain linear programsOperations Research Letters, 1999