The effect of inter-electrode distance on radial muscle displacement and contraction time of the biceps femoris, gastrocnemius medialis and biceps brachii, using tensiomyography in healthy participants
- 1 July 2019
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (7) , 075007
Abstract
Background : The systematic effect of inter-electrode distance on electrically elicited radial muscle displacement (Dm) and contraction time ( T c ) of the biceps femoris, gastrocnemius medialis and biceps brachii using tensiomyography (TMG) is currently unavailable. Objective : To investigate the effects of inter-electrode distance (4 cm, 5 cm, 6 cm and 7 cm) on Dm and T c of the biceps femoris, gastrocnemius medialis and biceps brachii, when the current amplitude is standardised. Approach : A within subject, repeated measures cross-over study. Participants : 24 participants. Main results : Biceps femoris and gastrocnemius medialis Dm increased with increased inter-electrode distance (biceps femoris: p = 0.015; gastrocnemius medialis: p = 0.000), yet T c were not affected ( p > 0.05). Biceps brachii Dm was not affected by inter-electrode distance ( p > 0.05), yet T c became shorter with increased inter-electrode distance ( p = 0.032). Significance : Inter-electrode distance affects Dm but not T c in two pennate muscles (biceps femoris and gastrocnemius medialis), and T c but not Dm in one parallel muscle (biceps brachii). Based on Dm measurements, optimal muscle specific inter-electrode distances were judged within the limits of this study. The following optimal inter-electrode distances are suggested: biceps femoris = 6 cm, gastrocnemius medialis = 7 cm and biceps brachii = 4 cm. Our findings emphasise the importance of accurate implementation and reporting of inter-electrode distance, for the reproducibility and comparability of studies using TMG.Keywords
This publication has 41 references indexed in Scilit:
- Assessment of eccentric exercise-induced muscle damage of the elbow flexors by tensiomyographyJournal of Electromyography and Kinesiology, 2012
- Tensiomiografia utilizada para a avaliação de jogadores de vôlei de praia de alto nívelRevista Brasileira de Medicina do Esporte, 2012
- The effectiveness of two novel techniques in establishing the mechanical and contractile responses of biceps femorisPhysiological Measurement, 2011
- Assessment of muscle fatigue after an ultra-endurance triathlon using tensiomyography (TMG)Journal of Sports Sciences, 2011
- Postural activation of the human medial gastrocnemius muscle: are the muscle units spatially localised?The Journal of Physiology, 2011
- Inter-rater reliability of muscle contractile property measurements using non-invasive tensiomyographyJournal of Electromyography and Kinesiology, 2010
- Effect of subcutaneous fat thickness and surface electrode configuration during neuromuscular electrical stimulationMedical Engineering & Physics, 2010
- Short-term repeatability of parameters extracted from radial displacement of muscle bellyJournal of Electromyography and Kinesiology, 2008
- Measuring of Skeletal Muscles' Dynamic PropertiesArtificial Organs, 1997
- Electrical stimulation-assisted rowing exercise in spinal cord injured people. A pilot studySpinal Cord, 1993