Effect of subcutaneous fat thickness and surface electrode configuration during neuromuscular electrical stimulation
Authors:
- Emer P. DohenyEDEmer P. Doheny
- Brian M. CaulfieldBCBrian M. Caulfield
- Conor M. MinogueCMConor M. Minogue
- Madeleine M. LoweryMLMadeleine M. Lowery
- 22 April 2010
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 32 (5) , 468-474
Abstract
The effect of subcutaneous fat thickness, electrode size and inter-electrode distance on the minimum stimulus current necessary for fiber excitation was examined in an attempt to improve the efficacy of neuromuscular electrical stimulation (NMES) in obese populations. A three-dimensional finite element model of the human thigh was developed and used to calculate the potential along a myelinated nerve fiber due to NMES. The activating function was used to examine alterations in the excitation of the fiber due to fat thickness, electrode size and inter-electrode distance. The finite element model was coupled to a neural model to examine the stimulus current required for action potential propagation. The stimulus current required to evoke 10% of the maximum M-wave amplitude was measured experimentally. Both experimental and modeling studies indicated that the stimulus current required to reach the threshold for muscle activation increased with fat thickness, electrode size, and inter-electrode distance. However, as fat thickness increased, the threshold for muscle activation became less sensitive to inter-electrode distance and electrode size. These results suggest that by using larger electrodes above regions of high subcutaneous fat thickness, the efficacy of NMES could be maintained while reducing the current density at the skin and the associated subject discomfort.Keywords
This publication has 29 references indexed in Scilit:
- Estimating neuromuscular stimulation within the human torso with Taser® stimulusPhysics in Medicine & Biology, 2007
- Anatomically based lower limb nerve model for electrical stimulationBioMedical Engineering OnLine, 2007
- Current distribution under electrodes in relation to stimulation current and skin blood flow: are modern electrodes really providing the current distribution during stimulation we believe they are?Journal of Medical Engineering & Technology, 2006
- Prolonged electrical muscle stimulation exercise improves strength and aerobic capacity in healthy sedentary adultsJournal of Applied Physiology, 2005
- Analysis of Calculated Electrical Activation of Denervated Muscle Fibers in the Human ThighArtificial Organs, 2005
- Interaction of array of finite electrodes with layered biological tissue: effect of electrode size and configurationIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2001
- Obesity as a barrier to physical activityAustralian and New Zealand Journal of Public Health, 2000
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- Modeling axon membranes for functional electrical stimulationIEEE Transactions on Biomedical Engineering, 1993