The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening
Authors:
- 21 April 2006
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 126 (6) , 369-373
Abstract
Introduction: Lengthening procedures are often complicated by loosening of pins. It has been reported that coating with hydroxyapatite improves fixation and reduces the rate of pin-track infection. Materials and Methods: We compared 47 hydroxyapatite-coated Schanz screws (HA screws) in 12 monolateral fixators mounted at the University Hospital Hamburg–Eppendorf with 45 standard stainless steel screws in 9 monolateral fixators mounted at the St Josefs-Hospital Wiesbaden by measuring the insertion and extraction torque values. The average implantation period was 7 months for the hydroxyapatite-coated screws and 5.4 months for the uncoated screws. We established the quotient of the maximum extraction torque over insertion torque which shows the change in the fixation strength with respect to time, the fixation index. It eliminates the influence of the varying pin–bone contact. Results: There was no significant difference in the rate of infection. In the Schanz screws without signs of infection the index was 1.92 for the HA screws and 0.76 for the stainless steel screws (P = 0.0002) giving evidence of the improvement of the fixation by the coating. Conclusion: HA coating resulted in improved fixation of Schanz screws in bone and may be useful in prolonged external fixation of the lower leg. The fixation index proved to be a simple tool for the evaluation of the fixation strength of Schanz screws.Keywords
This publication has 13 references indexed in Scilit:
- HA-coated Screws Decrease the Incidence of Fixation Failure in Osteoporotic Trochanteric FracturesClinical Orthopaedics and Related Research, 2004
- Hydroxyapatite-Coated Schanz Pins in External Fixators Used for Distraction OsteogenesisJournal of Bone and Joint Surgery, 2002
- Zur knöchernen Verankerungsfestigkeit hydroxylapatitbeschichteter Schanz-Schrauben des Heidelberg External Fixation Systems (HEFS) - Vergleichende Drehmomentmessungen im klinischen Einsatz und an der Leichentibia / Bone Fixation Strength of Hydroxyapatite-Coated Schanz Screws of the Heidelberg External Fixation System (HEFS) - Determination of Torque in Clinical Application and in a Cadaveric TibiaBiomedical Engineering / Biomedizinische Technik, 2002
- Fixation Strength and Pin Tract Infection of Hydroxyapatite-Coated Tapered PinsClinical Orthopaedics and Related Research, 2001
- Improvement of the Bone-Pin Interface Strength in Osteoporotic Bone with Use of Hydroxyapatite-Coated Tapered External-Fixation PinsJournal of Bone and Joint Surgery, 2001
- Evaluation hydroxylapatitbeschichteter Schanz-Schrauben bei Verwendung des Heidelberg External Fixation System (HEFS) - Evaluation of Hydroxyapatite-coated Schanz Screws Used in the Heidelberg External Fixation System (HEFS)Biomedical Engineering / Biomedizinische Technik, 2001
- A Comparison of Hydroxyapatite-Coated, Titanium-Coated, and Uncoated Tapered External-Fixation Pins. An in Vivo Study in Sheep*Journal of Bone and Joint Surgery, 1998
- Enhanced Fixation With Hydroxyapatite Coated PinsClinical Orthopaedics and Related Research, 1998
- Increase of stability in external fracture fixation by hydroxyapatite‐coated bone screwsJournal of Applied Biomaterials, 1995
- Experimentelle Untersuchungen und klinische Ergebnisse zur Stimulation der Knochenregeneration mit zerkleinerter Kortikalis und porösen Kalziumphosphatkeramiken (Trikalziumphosphat und Hydroxiapatit)1991