Quantifying the blood oxygenation level dependent effect in cerebral blood volume–weighted functional MRI at 9.4T
Authors:
Open Access
- 30 August 2007
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 58 (3) , 616-621
Abstract
In cerebral blood volume (CBV)‐weighted functional MRI (fMRI) employing superparamagnetic contrast agent, iron dose and blood oxygenation level dependent (BOLD) contamination are two important issues for experimental design and CBV quantification. Both BOLD and CBV‐weighted fMRI are based upon the susceptibility effect, to which spin‐echo and gradient‐echo sequences have different sensitivities. In the present study, CBV‐weighted fMRI was conducted using spin‐echo and gradient‐echo sequences at 9.4T by systematically changing the doses of contrast agent. Results suggest that BOLD contamination is a significant component in CBV‐weighted fMRI at high field, particularly when relatively low dose of contrast agent is administered. A mathematical model was developed to quantify the extravascular (EV) BOLD effect. With a TE of 35 ms, the EV BOLD effect was estimated to account for 76 ± 12% of the observed spin‐echo fMRI signal at 9.4T. These data suggest that correcting BOLD effect may be necessary for accurately quantifying activation‐induced CBV changes at high field. Magn Reson Med 58:616–621, 2007.Keywords
This publication has 15 references indexed in Scilit:
- Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: Insights into hemodynamic regulationNeuroImage, 2006
- Combined imaging–histological study of cortical laminar specificity of fMRI signalsNeuroImage, 2006
- Exogenous contrast agent improves sensitivity of gradient‐echo functional magnetic resonance imaging at 9.4 TMagnetic Resonance in Medicine, 2004
- Spatial correlations of laminar BOLD and CBV responses to rat whisker stimulation with neuronal activity localized by Fos expressionMagnetic Resonance in Medicine, 2004
- Columnar Resolution of Blood Volume and Oximetry Functional Maps in the Behaving MonkeyNeuron, 2004
- Columnar Specificity of Microvascular Oxygenation and Volume Responses: Implications for Functional Brain MappingJournal of Neuroscience, 2004
- Comparison of diffusion‐weighted high‐resolution CBF and spin‐echo BOLD fMRI at 9.4 TMagnetic Resonance in Medicine, 2002
- Dynamic liver imaging with iron oxide agents: Effects of size and biodistribution on contrastMagnetic Resonance in Medicine, 1997
- The intravascular contribution to fmri signal change: monte carlo modeling and diffusion‐weighted studies in vivoMagnetic Resonance in Medicine, 1995
- Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical modelBiophysical Journal, 1993